566857
3
Zoom out
Zoom in
Vorherige Seite
1/4
Nächste Seite
HALOGEN HAND LAMP 500W + camera
EN - 3
PLI-126
2. Setting the correct frequency.
To prevent picture flicker you must set the correct
frequency of the supply, being. 50Hz or 60Hz. This is
done when the camera is in TEST MODE. Repeatedly
press the MODE button until the correct frequency
appears on the screen, 50Hz for Europe.
Press the SET button to confirm. “DONE” now appears
on the display.
Then press SET to leave the menu.
To leave TEST MODE press SET + MODE together.
3. Setting the recording selection, time and interval.
You can set an interval beforehand before a next photo
is taken. You then avoid the camera taking a number of
photos of the same person.
Press the MODE button for 2 seconds to change the
camera settings.
Then repeatedly press the MODE button until “TO-05”
flashes. “to” stands for time out” and “05 stands for
the number of minutes. Press the SET button to
change the time interval to max. 60.
Press MODE to confirm and go to the next setting, the
resolution.
4. Setting the resolution
Repeatedly press the MODE button until the asterisks
flash. Choose 1 asterisk if you want low resolution
pictures (1.3 mpx), choose 3 asterisks for high
resolution pictures (2.0 mpx).
Press SET to confirm. “DONE” now appears on the
display. You are now at the next setting, photo or
video.
5. Setting photographs or video pictures
Repeatedly press the MODE button until
or flashes.
means that 1 photo is taken when the PIR
detects movement.
Means that 2 photos are taken when the PIR
detects movement.
Means that filming takes place for 10 seconds
when the PIR detects movement.
Press SET to confirm and go to the next setting,
halogen lighting.
6. Setting the halogen lighting.
Repeatedly press the MODE button until Auto” or
“OFF” flashes.
Auto The halogen hand lamp will
automatically start working when the
camera sensor detects movement,
also when the set light intensity (LUX)
has not yet been reached.
OFF The halogen hand lamp will only start working
when the camera sensor detects movement
and the set light intensity (LUX) has been
reached.
Press SET to confirm and go to the next setting,
camera settings.
7. Leaving camera settings.
Repeatedly press the MODE button until ESC”
flashes.
Press SET to confirm.
“DONE” now appears on the display. The camera
now counts down 60 seconds. The settings then
apply.
Deleting saved pictures
Press SET and MODE once together. On the display
the word “Test” appears”. The camera is now in
TEST MODE.
Repeatedly press the MODE button until the
following icons are visible:
or
Press the SET button to confirm.
Press the SET button again until “ESC” appears on
the screen.
To leave the menu and save the settings press SET
+ MODE again together.
Viewing driver settings and pictures
The software CD-ROM supplied with the halogen
hand lamp is only compatible with PC, not with MAC.
After the installation of the CD-ROM you can view
the saved pictures.
The pictures in the built-in memory can be put on
your PC with the USB cable supplied.
You can view the pictures on your SD card on your
PC through the input provided.
Maintenance
Only use a dry, soft cloth for cleaning the halogen
hand lamp. And make sure that the lamp has first
cooled down.
Never immerse the lamp in water.
Maintenance and repairs may only be carried out by
technicians who are familiar with any applicable
regulations.
Safety instructions
The importer accepts no responsibility for damage
claims with respect to objects or persons that result
from incorrect use or non-compliance with the safety
instructions. All damage claims in such cases will be
declared null and void.
When replacing the halogen bulb the lamp must first
have cooled before the bulb is replaced. Also
disconnect the power supply. Do not exceed the
maximum wattage of 500W.
NOTE
: Never touch the bulb with your fingers.
Touching the bulb with your fingers can reduce the
life of the bulb.
Always replace cracked or broken glass by glass
with the same properties as the original glass.
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Profile PLI-126 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Profile PLI-126

Profile PLI-126 Bedienungsanleitung - Holländisch - 4 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info