EXTERNAL POWER SUPPLY
The sight can be powered with an external DC power supply (2.1mm pin)
with stabilized voltage ranging from 8V to 15V or a 12V vehicle socket.
џ Connect the plug (13) of the cable to the jack (10) of the sight by matching
the notch in the plug connector and the protrusion of the jack (10) (see the
scheme).
џ Secure the cable by turning clockwise the locking ring of the plug (13).
џ Connect the external power supply (AC/DC) or car adapter to the jack (15)
of the cable.
Note: central pin of the power supply that you connect to the “power” jack of
the sight, must have marking “+”.
џ The power supply may have marking .
џ Connection of an external power supply (icon on the status bar)
automatically cuts off power supply from batteries.
џ External power supply DOES NOT charge the batteries in the sight!
Attention! We suggest that you use battery packs EPS3 or EPS5 ensuring
from 9 to 20 hours of continuous operation.
OPERATION
Installation of mount
Before using the sight you need to install the mount (12).
The sight can be used with various mount types such as Weaver, Euro-
prism, Los, Side mount, MAK adapter etc. that allow the scope to be installed
on different types of rifles.
The mounting holes in the base of the sight enable the mount to be installed
in one of the multiple positions. The choice of the mounting position helps the
user to ensure the correct eye relief depending on the rifle type.
џ Attach the mount to the base of the sight using a hex-nut wrench and
screws (see installation scheme).
џ Install the scope on the rifle and check if the position is suitable for you.
џ If you are happy with its position, remove the scope, unscrew the screws
halfway, apply some thread sealant onto the thread of the screws and
tighten them fully (do not overtighten). Let the sealant dry for a while.
џ The sight is ready to be installed on a rifle and to be zeroed.
џ After first installation of your sight on a rifle, please follow instructions in the
section “Zeroing”.
Note. Please check that your sight is duly zeroed after changing a mount.
Powering on and calibration
џ Press briefly the “ON” (1) button to power on the sight. In case of low
battery icon will start flashing.
џ Do the calibration of image. Calibration levels background temperature of
the microbolometer and eliminates image flaws.
џ There are three calibration modes: manual (M), semiautomatic (H) and
automatic (А).
8
Manual (silent) calibration mode
џ The lens cap (8) should be closed.
џ Power on the sight with the “ON” (1) button, hold down the controller (9) for
two seconds to enter the menu.
џ Rotate the controller to select option Cal. Press the controller.
џ Rotate the controller to select mode М. Press the controller to confirm. To
exit the menu, press and hold the controller (9) for two seconds or wait 10
seconds for automatic exit.
џ Press the CAL (2) button to calibrate. The image will freeze for 1-2
seconds. Then open the lens cap. Calibration is completed.
џ In case you see image flaws (such as frozen image, vertical stripes etc.) re-
calibrate the unit with the lens cap closed.
Semiautomatic calibration mode
џ Power on the unit, open the lens cap.
џ Hold down the controller (9) for two seconds to enter the menu.
џ Rotate the controller to select option Cal. Press the controller.
џ Rotate the controller to select mode H. Press the controller to confirm.
џ Press the CAL (2) button to calibrate. The image will freeze for 1-2 seconds
and you will hear the sound of the internal shutter. Calibration is
completed.
Automatic calibration mode
With the automatic calibration mode the thermal imager calibrates by itself
according to the software algorythm. The detector (microbolometer) is
closed with the shutter automatically. User assisted calibration with the CAL
(2) button is allowed in this mode.
џ Power on the unit, open the lens cap.
џ Hold down the controller (9) for two seconds to enter the menu.
џ Rotate the controller to select option Cal. Press the controller.
џ Rotate the controller to select mode A. Press the controller to confirm.
џ At the moment of the automatic calibration the image will freeze for 1-2
seconds and you will hear the sound of the internal shutter.
џ Time intervals between calibrations depend on the heat of the detector.
The unit may require calibration more frequently on activation.
Focusing and image adjustment
џ Open the lens cap (8).
џ Adjust sharp image of the display icons by turning the eyepiece ring (5).
џ To adjust display brightness, rotate the controller (9). Brightness level
(from 0 to 20) will appear next to the brightness icon in the top right
corner of the display.
џ To adjust display contrast, press the controller (icon appears) and rotate
it. Contrast level (from 0 to 20) will appear next to the contrast icon in the
top right corner of the display.
џ Point the unit at a warm object located at a certain distance, 100 meters, for
example.
џ Adjust the focus by turning the ring for lens internal focusing (6).
џ After this adjustment no further dioptre adjustment should be required,
regardless of distance or other factors. Adjust image quality only with the
ring (6) for lens internal focusing.
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Pulsar Apex LD38 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info