Unit description
Operating sequence
The unit is ready for operation
when the power key is pressed.
The integrated hygrostat controls
the unit’s operation according to
the settings.
In dehumidification mode, the fan
extracts the moist room air through
the intake grill with filter, evaporator
and the condenser behind.
Heat is removed from the room air
on the cold evaporator. The air is
then cooled to below dew point.
The water vapour contained in
the room air is then deposited
as condensate or rime on the
evaporator fins.
On the condenser (heat
exchanger), the cold and
dehumidified air is warmed up
again and discharged back into
the room via the outlet grill
with a temperature increase of
around 5 - 10 °C above the room
temperature.
The processed, dry air then re-
mixes with the room air.
Continuous circulation of the room
air through the unit gradually
reduces the relative humidity
(% RH) in the room to the desired
humidity level.
Depending on the room air
temperature and the relative
humidity, condensed water will
drip into the condensate trap and
then into the condensate container
below either continuously or only
during the defrosting phases.
A float is installed inside the
condensate container. In the event
that the container is full, the float
will activate a microswitch which will
switch off dehumidification mode.
The units switch off and the
“container full” indicator light on
the control panel flashes.
This extinguishes again when the
empty condensate container is re-
inserted.
Dehumidification mode then starts
after a switch-on delay of around
3 minutes depending on the
requirements.
In unattended continuous
operation with an external
condensate connection, the
condensate that occurs is
drained continuously via a hose
connection or pumped out using
the integrated condensate pump if
required.
The units have been designed for
universal and straightforward air
dehumidification.
Their compact dimensions allow
the unit to be transported and set
up with ease.
The units operate in accordance
with the condensation principle
and are equipped with
a hermetically sealed refrigerant
system, heat gas defrosting, low-
noise and low-maintenance fan
and connection cable with plug.
Fully-automatic operation,
a condensate container with
integrated overflow protection
in addition to connection ports
for direct condensate drainage or
a condensate pump connection
help to ensure continuous fault-
free operation.
The units conform to the
fundamental health and safety
requirements of the appropriate
EU stipulations.
The units are dependable and offer
ease of operation.
The units are used in all locations,
where dry air is a must and where
economic consequential damage
(such as that caused by mould)
must be prevented.
The units may be used for the
drying and dehumidification of
areas such as:
Living rooms, bedrooms,
shower rooms or cellar rooms
Laundry rooms, weekend
homes, caravans
Warehouses and laboratories
Bathrooms, wash rooms and
changing rooms etc.
Cellar rooms, storage rooms
Condensate container
Condenser
Evaporator
Compressor
Schematic depiction of the workings of the REMKO air dehumidifier
Moist room air
Dehumidified
room air
Recirculating fan
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für REMKO ETF460 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von REMKO ETF460

REMKO ETF460 Bedienungsanleitung - Deutsch - 20 seiten

REMKO ETF460 Bedienungsanleitung - Holländisch - 20 seiten

REMKO ETF460 Bedienungsanleitung - Französisch - 20 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info