735223
2
Zoom out
Zoom in
Vorherige Seite
1/2
Nächste Seite
Press for 3 seconds
to manually open
Press for 3 seconds
to manually close
LED ashes green once and then goes out.
To check status refer to table above.
LED ashes red once and then goes out.
To check status refer to refer to table above.
Short press to return to Auto mode.
Red LED will ash once to conrm that
the unit is in AUTO.
Using the Unit
Auto Lock Function
Auto lock function is disabled until you have gone through the pairing process. After
pairing, the TRV will auto lock after 5 minute if no buttons have been pressed.
Unlocking the Buttons
To unlock the buttons, press the pairing and close buttons together for 3 seconds.
Opening the Valve Manually
Press the open button for 3 seconds. The LED ashes green once and the valve opens.
Closing the Valve Manually
Press the close button for 3 seconds. The LED ashes red once and the valve closes.
Entering Fail Safe Mode
In fail safe mode, the unit opens the valve 25% for water ow to maintain room
temperature.
To enter fail safe mode, press and hold the open and close buttons together for 3 seconds.
To exit fail safe mode, press the:
Pairing button to put the unit in automatic mode
Open button for 3 seconds to open the valve
Close button for 3 seconds to close the valve
Restoring Factory Default Settings
Press the pairing, open, and close buttons together for 10 seconds.
Protecting against Frost
When you have manually closed the valve, the unit automatically enables frost
protection. Frost protection starts only when the temperature in the room drops below
the frost temperature setpoint. The unit does all this automatically when connected to a
thermostat and you don’t have to do anything.
Using the Unit
Detecting Open Windows
The unit checks the rate of temperature drop in the room in which it is located. If the drop
is rapid, it assumes a window in the room has been opened. This only works if the unit is
paired to the thermostat and is in automatic mode and the battery in the unit is not low.
The unit does all this automatically when connected to a thermostat and you don’t have
to do anything. It works between 0 and 40⁰C.
Protecting against Lime Scale
Do not leave a valve open for a long time because this could cause a build up of lime scale.
The unit has a lime-scale protection feature to prevent against this. The valve motor
automatically starts once a week if no valve movement has been detected within a 14-
day period. Lime-scale protection will continue to operate in automatic, manual open,
and manual close modes and you don’t have to do anything.
Auto Adaptation
Once the batteries are inserted into the unit, the red light will appear. If no keys are pressed
it will auto adapt to the valve.
Button Usage
To do this… Press the…
Leave the network Pairing button for 10 seconds (when unit already in network)
Pair with thermostat Pairing button for 10 seconds
Put unit in automatic mode Short press Pairing button
Fully open the valve Open button for 3 seconds
Fully close the valve Close button for 3 seconds
Restore factory default settings Open, pairing, and close buttons together for 3 seconds
Lock and unlock the buttons Pairing and close buttons together for 3 seconds
Wireless Radiator Controller
Model: TRV10RFM
INSTRUCTION MANUAL
www.salus-controls.com
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road,
Dodworth, Barnsley S75 3SP, UK.
SALES:
T: +44 (0) 1226 323961
E: sales@salus-tech.com
TECHNICAL
: T: +44 (0) 1226 323961
E: tech@salus-tech.com
Maintaining a policy of continuous product development, SALUS Controls plc reserves the right to change
specication, design and materials of products listed in this brochure without prior notice.
SALUS Controls is a member of the Computime Group
Issue Date: Dec 2014
00086/2
For PDF Instruction Manual go to
www.salus-controls.com
Technical Detail
SALUS Controls warrants that this product will be free from any defect
in materials or workmanship, and shall perform in accordance with its
specification, for a period of five years from the date of installation.
SALUS Controls sole liability for breach of this warranty will be (at its option)
to repair or replace the defective product.
Warranty
Model TRV10RFM
Type Hydraulic Radiator Valve
DC Motor
M30 x 1.5
LED Indicator Bi-Colour, Red/Green
Valve Adaptation Automatic
Power Source 2x AA Batteries
Battery Life 14 Months (low battery indication)
Control Method Modulating
Communication 2.4GHz ZigBee wireless
Operating Temperature 0 to 45ºC
Storage Temperature -20 to 60ºC
Operating Humidity 5 to 95”RH
Protection IP30
Size (mm) H 88.6, W 51
Manual open/status indication
Manual close/status indication
• Pairing
Customer Name: ..................................................................................
Customer Address: ..............................................................................
....................................................... Post Code: ....................................
Tel No: .................................................................................................
Email: ..................................................................................................
Engineers Company: ............................................................................
Tel No: .................................................................................................
Email: ..................................................................................................
Instalation Date: ..................................................................................
Engineers Name: .................................................................................
Engineers Signature: ...........................................................................
To remove the unit from auto mode, follow the steps below. If the buttons
are locked, unlock them by pressing the pairing and close buttons together
for 3 seconds.
Manual Override
LED Indications
100% open
0% open
1 to
100% open
0% open
100% open
0% open
100% open
25% open
Power switched
on or after reset
Unit adapting
to valve
Unit has not
joined network
or has not paired
to thermostat
Unit paired to
thermostat and
in auto mode
Leaving network
Identifying the
network
When... The LEDs... Valve
Software Version
indication
Auto mode
Manual open
Manual close
A sequence of red and green LEDs ashing
displayed indicates the software version
Red ashes then goes steady. Green ashes (or red
asheson failure to adapt). Green steady.
Green and red ash (or red ashes on failure to adapt)
Green and red ash alternately after short press on
open or close button
Green ashes twice after short press on open or
close button
Red ashes twice after short press on open or
close button
No LED
Red and green on together for one second
Green ashes for up to 10 minutes
25% open
100% open
0% open
Wireless
link to
thermostat
lost
Normal
operation
Battery low
Error installing
Auto mode
Manual open
Manual close
Auto mode
Auto mode
Manual open
Manual close
Window open
mode active
Green and red ash alternately after short press on
open or close button
Green ashes twice after short press on open or
close button
Red ashes twice after short press on open or
close button
Green ashes once after short press on open or
close button
Red ashes once after short press on open or
close button
Green ashes twice after short press on open or
close button
Red ashes twice after short press on open or
close button
Green and red ash twice every 10 seconds
Red ashes three times every 10 seconds
(less if the battery is low)
Green and red ash alternately
Input Three push buttons:
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Salus TRV10RFM wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info