Do not install the battery if the sounder is disconnected.
There is a danger of battery explosion when using a different battery than recommended by the
manufacturer, or handling the battery improperly.
Be particularly careful during installation and replacement of the battery. The manufacturer is
not liable for the consequences of incorrect installation of the battery.
1. Remove the plastic dust cap.
2. Turn the cover counter-clockwise (Fig. 2) and remove it (Fig. 3).
3. If the detector is to work as a stand-alone device, remove the jumper (designated by letter B on Fig. 4) from
the pins situated on the electronics board and skip the steps 5-8.
Note: After the battery is installed, removing / placing the jumper will have no effect on the detector operation.
4. Install the battery.
5. Add the detector to the wireless system (see the ACU-120 / ACU-270 controller manual, installer manuals
for INTEGRA 128-WRL or VERSA control panels).
6. Close the enclosure and temporarily fasten the detector at the future installation place.
7. Check the level of signal received from the detector by the ABAX controller or the INTEGRA 128-WRL
control panel. If the signal level is lower than 40%, select another place for installation. Sometimes, it is
sufficient to shift the device ten or twenty centimeters to obtain a considerable improvement in the signal
quality.
8. Open the enclosure.
9. Using wall plugs (screw anchors) and screws, secure the enclosure base to the wall. The wall plugs (screw
anchors) and screws delivered with the detector are intended for brick, concrete and similar mounting
surfaces. For other surfaces (e.g. drywall, wood, styrofoam), use other wall plugs (screw anchors), as
required.
10. Close the detector enclosure.
11. Press and hold down the test / reset button (designated with the letter A in Figure 2). Alarm should be
triggered after a few seconds.
12. If any other operations which may cause contamination of the optical chamber are being carried in the
facility where the detector is installed, the detector must be temporarily covered with a plastic dust cap.
4. Maintenance
The detectors should be subject to regular checks to ensure they are working correctly. Periodic checks should
be conducted at least every six months. To check whether the detector works, press and hold down the test /
reset button (designated with the letter A in Figure 2). Alarm should be triggered after a few seconds.
Cleaning the optical chamber
The detector is monitoring the state of the optical chamber. Deposition of dust in it may lead to malfunctioning of
the device. It is recommended that you have the optical chamber cleaned at least once a year. Cleaning the
chamber is necessary when the LED indicates fouling of the chamber (operation as part of the ABAX system –
2 short flashes during polling; stand-alone mode – 2 flashes every 30 seconds).
1. If the detector is used in the ABAX system, start the service mode in the control panel.
2. Remove the screw fastening the cover (Fig. 1).
3. Turn the cover counter-clockwise (Fig. 2) and remove it (Fig. 3).
4. Remove the battery.
5. Disconnect the plug (designated by letter A in Fig. 4) connecting the sounder wires with the electronics
board.
6. Push outward the catches (Fig. 5) and take out the electronics board with the optical chamber (Fig. 6).
7. Push outward the catch securing the optical chamber cover (Fig. 7) and remove it (Fig. 8).
8. Using a soft brush or compressed air, clean the labyrinth in the cover, as well as the base of the optical
chamber, paying attention to the recesses where LEDs are installed.
9. Replace the cover of the optical chamber.
10. Lay the sounder wires in their corresponding grooves.
11. Secure the electronics board with the optical chamber in the cover mounting catches. The board must be
mounted so that the LED coincides with the light guide.
12. Reconnect the plug connecting the sounder wires with the electronics board.
13. Re-install the battery.
14. Close the detector enclosure.
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Satel ASD-150 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Satel ASD-150

Satel ASD-150 Bedienungsanleitung - Deutsch - 4 seiten

Satel ASD-150 Bedienungsanleitung - Holländisch - 4 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info