781654
24
Zoom out
Zoom in
Vorherige Seite
1/148
Nächste Seite
www.scheppach.com / service@scheppach.com / +(49)-08223-4002-99 / +(49)-08223-4002-58
24 | GB
Material mixtures are particularly dangerous. Light
metal dust can burn or explode.
Set the correct speed before starting work. The
speed must be appropriate for the drill diam-
eter and the material to be drilled. At an incor-
rectly set speed the bit may get jammed in the
workpiece.
Only when the device is turned on should the
bit be moved against the work piece. Otherwise
there is a danger that the bit will get jammed in the
workpiece and the workpiece will rotate with the
bit. This can lead to injuries.
Do not put your hands in the area of the drill
while the power tool is running. Upon contact
with the bit is a risk of injury.
Never remove drilling chips from the drilling
area while the power tool is running. Always
put the drive mechanism in the standby position
rst and then turn on the power tool.
Do not remove accumulated drill chips with
your bare hands. There is a risk of injury due to
hot and sharp metal shavings in particular.
Break up long drilling chips by interrupting the
drilling operation with a short backward rota-
tion of the rotary wheel. Long drilling chips may
cause injury.
Keep handles dry, clean and free from oil and
grease. Greasy, oily handles are slippery and lead
to loss of control.
Use clamps to hold the workpiece in place. Do
not work on any workpieces that are too small
for clamping. If you hold the workpiece by hand,
you cannot hold it sufciently tightly against rota-
tion and may hurt yourself.
Switch the power tool off immediately if the bit
jams. The bit jams when:
- the power tool is overloaded or
- the workpiece to be machined is jammed.
Do not touch the bit after working before it has
cooled down. The bit is very hot during use.
Inspect the cable regularly and have a dam-
aged cable repaired only by an authorised cus-
tomer service centre. Replace damaged exten-
sion cables. This will ensure that the power tool
remains safe.
Store unused power tools in a safe place. The
storage place should be dry and lockable. This
prevents the power tool from being damaged as
a result of being stored or operated by inexperi-
enced people.
Never leave the tool before it has come to a
complete standstill. After running bits can cause
injury.
Do not use the power tool with a damaged ca-
ble. Do not touch the damaged cable and pull
the mains plug if the cable is damaged while
working. Damaged cables increase the risk of
electric shock.
Use extension cables for outdoors
- Only use approved and appropriately identied ex-
tension cables for use outdoors.
Remain attentive
- Pay attention to what you are doing. Remain sen-
sible when working. Do not use the electric tool
when you are distracted.
Check the electric tool for potential damage
- Protective devices or other parts with minor dam-
age must be carefully inspected to ensure that they
function correctly and as intended prior to contin-
ued use of the electric tool.
- Check whether the moving parts function faultless-
ly and do not jam or whether parts are damaged.
All parts must be correctly mounted and all condi-
tions must be fullled to ensure fault-free operation
of the electric tool.
- Damaged safety equipment and parts must be re-
paired properly or replaced by an authorised spe-
cialist workshop unless otherwise indicated in the
instructions.
- Damaged switches must be replaced at a customer
service workshop.
- Do not use any electric tool on which the switch
cannot be switched on and off.
ATTENTION!
- The use of other insertion tools and other acces-
sories can entail a danger of injury.
Have your electric tool repaired by a qualied
electrician
- This power tool complies with the relevant safe-
ty regulations. Repairs may only be performed by
a qualied electrician, using original spare parts;
otherwise accidents involving the user may result.
Warning! This electric tool generates an electromag-
netic eld during operation. Thiseld can impair ac-
tive or passive medical implants under certain condi-
tions. In order to prevent the risk of serious or deadly
injuries, we recommend that persons with medical
implants consult with their physician and the manu-
facturer of the medical implant prior to operating the
electric tool.
Service:
Only have your electric tool repaired by quali-
ed specialists and only with original spare
parts. This will ensure that the power tool remains
safe.
Safety Instructions for Box Column Drills
Never make the warning labels on the power
tool illegible.
Attach the power tool to a solid, at and hori-
zontal surface. If the power tool can slip or wob-
ble, the bit may not be guided smoothly and safely.
Keep the work area clean except for the
workpiece to be machined. Sharp-edged
drilling chips and objects can cause injury.
24

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Scheppach DP19Vario wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info