727456
12
Zoom out
Zoom in
Vorherige Seite
1/13
Nächste Seite
10/2019
- 12 -
Copyright © 2019, Fast ČR, a.s.
Cleaning the outer case
To clean the outer case, use asoft wiping cloth dipped in asolution of lukewarm water and neutral detergent. Then wipe the surface dry.
When cleaning it, do not spray the portable air conditioner with water or any other liquid, do not pour water on it or submerge it in water or in any other liquid.
Do not use abrasive cleaning products, solvents, petrol, etc. for cleaning.
Storing the portable air conditioner
In order to dry it and to prevent the formation of moulds, leave the portable air conditioner running in awarm room in the fan mode for approximately 12 hours.
Disconnect the flexible hose B1 and store it in asafe place out of the reach of children.
Drain all the condensate from the condensate tank – see chapter Condensate drain outlet”.
Clean the air filters and reinstall them. Wipe the outer case of the portable air conditioner. Remove the batteries from the remote control.
Store the air conditioner in acool, dry and dark location.
Condensate drain outlet
If the water level inside the condensate tank reaches apredetermined level, the portable air conditioner will show “Ft (full condensate tank) on the display C6. In order to drain
the condensate from the air conditioner, proceed as follows:
1. Disconnect the power plug from the power socket.
2. Carefully re-locate the portable air conditioner to alocation where the water may be drained.
3. Underneath the drain outlet A10, place acontainer into which the condensate will flow. Carefully remove the plug of the drain outlet A10. Connect the drain hose B6 and
allow the condensate to flow out.
4. Once the condensate tank is empty (condensate has stopped flowing), disconnect the drain hose B6 and put the plug back into the drain outlet A10.
5. Insert the power plug into apower socket and turn on the portable air conditioner.
If you need to ensure the condensate to be continuously drained from the portable air conditioner, it is possible to connect the drain hose B6 to awaste water drain. Proceed as follows:
1. Disconnect the power plug from the power socket.
2. Remove the plug of the top drain outlet A8. Connect the drain hose B6. If the length of the drain hose B6 is insufficient, then it is necessary to purchase alonger hose of the
same type. Never extend the length of the drain hose B6 using extensions.
3. Connect the end of the drain hose B6 to the waste water drain.
4. Insert the power plug into apower socket and turn on the portable air conditioner.
Note:
The drain hose B6 should be installed at the same height or lower than the top drain outlet A8. Otherwise, the condensate will not be properly drained from the
condensate tank.
Putting into operation again
Check that the power cord and plug are not damaged and that the air filters are clean. Insert anew set of batteries into the remote control. Proceed according to the instructions
in section “Inserting and replacing batteries”. Install the portable air conditioner according to the instructions contained in the preceding part of this user’smanual “Installation”.
TROUBLESHOOTING
Error messages
Shown on the display Meaning Solution
Low temperature The portable air conditioner has asystem that prevents freezing at very low temperatures.
The air conditioner will start again once the internal system is defrosted.
Defect of the heat sensor Contact an authorised service centre.
Full condensate tank Empty the condensate tank. Proceed according to the instructions in section "Condensate drain outlet" described
previously in this user'smanual.
Note:
In the event that one of the aforementioned faults occurs, turn off the portable air conditioner and check for the cause of the fault. Turn it on again, and if the fault
reoccurs, turn it off, disconnect the power cord from the power socket and contact the manufacturer, an authorised service centre or aperson with relevant qualifications
and have the unit repaired.
Troubleshooting
Before contacting an authorised service centre, please check the appliance according to the following instructions:
Problem Possible cause Remedy
The portable air conditioner did not turn on. There is no current in the power socket. Engage the circuit breaker or, alternatively, try adifferent power socket.
The power plug is not inserted in apower socket. Connect the power plug to the power socket.
The internal safety fuse is disengaged. Wait 30 minutes, and if the problem persists, please contact an authorised
service centre.
The portable air conditioner runs only for
ashort time.
The flexible air exhaust hose B1 is not connected
or it is blocked.
Turn off the air conditioner, disconnect the hose, check that it is not
blocked and reconnect the hose.
Air inlets A7 and A9 are blocked. Remove the obstacles preventing air supply to the inlets.
The portable air conditioner is on, but is not
cooling.
The windows and doors of the room are open. Make sure that all doors and windows are closed.
There are heat sources inside the room. If possible remove these heat sources.
The flexible air exhaust hose B1 is not connected. Attach the flexible hose B1.
The room area is too large. Perform adouble-check of the cooled area.
An unpleasant odour is sensed while it is
running.
The air filters are clogged with dirt and dust or
animal fur.
Turn off the air conditioner and clean the filters according to the provided
instructions.
The portable air conditioner turns off approx.
3minutes after it is turned on again.
Then compressor'ssafety fuse is protecting the
air conditioner against damage if turned on
sooner than after 3 minutes.
Wait several minutes and then turn the air conditioner on again.
An error message appeared on the display C1. Proceed according to the instructions in section "Error messages".
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sencor SAC MT1225CH wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info