EN Portable Air Conditioner
User´smanual
Prior to using this appliance, please read the user‘smanual thoroughly, even in cases,
when one has already familiarised themselves with previous use of similar types of
appliances. Only use the appliance in the manner described in this user’smanual.
Keep this user‘smanual in asafe place where it can be easily retrieved for future use.
We recommend saving the original cardboard box, packaging material, purchase
receipt and responsibility statement of the vendor or warranty card for at least the
duration of the legal liability for unsatisfactory performance or quality. In the event
of transportation, we recommend that you pack the appliance in the original box
from the manufacturer.
DESCRIPTION OF THE APPLIANCE
A1 Control panel
A2 Air outlet
A3 Remote control storage slot
A4 Handles (located along both sides)
A5 Travel wheels
A6 Universal power cord plug plate
A7 Top drain outlet
A8 Bottom drain outlet
A9 Removable grille with filter (top
evaporator air inlet is located under
the grille)
A10 Air outlet to connect the flexible
hose
A11 Bottom air inlet of the condensation
unit
A12 Power cable
DESCRIPTION OF THE ACCESSORIES
B1 Remote control (batteries included)
B2 Sealing kit for roof, sash, and tilt-
open windows:
- textile protection with azip
- tape of self-adhesive velcro
B3 Plastic window set for sliding and
roof windows (screws included)
B4 Wide flexible hot air exhaust hose
B5 Inlet hose adaptor
B6 Outlet hose adaptor
B7 Sealing
B8 Drain hose
DESCRIPTION OF THE CONTROL PANEL
C1 Timer indicator
C2 Wi-Fi indicator (valid only for Wi-Fi
models)
C3 Low speed fan indicator
C4 High speed fan indicator
C5 Display
C6 Cooling mode indicator
C7 Dehumidification mode indicator
C8 Fan mode indicator
C9 button to set the timer
C10 button to set the fan speed
C11 + button
C12 – button
C13 button to select an operation
mode
C14 button to turn on / off
REMOTE CONTROL
D1 button to turn on / off
D2 to select an operation mode
D3 + button
D4 button to set the timer
D5 button to set the sleep mode
D6 – button
D7 button to set the fan speed
D8 °C / °F button to change the
temperature unit
Note:
The SWING function is available only for certain models.
INSTALLATION
Location of the portable air conditioner
Locate the portable air conditioner on an even, dry, and stable surface and within
reach of agrounded power socket.
For easier handling, the portable air conditioner is equipped with travel wheels A5.
Do not use the travel wheels A5 when you need to move the air conditioner over
carpets or similar surfaces. Avoid riding over objects.
To achieve optimal efficiency, maintain adistance of at least 45 cm from the wall
or other obstacles.
Warning:
Do not block the air inlet or air outlet.
Note:
Do not use the portable air conditioner to cool aroom where computer
servers, etc. are located.
Installation, adjustment, maintenance, and repairs must only be
performed by aqualified person.
Installation of flexible hose on to the portable air conditioner
The flexibl hose B4 must be connected to the portable air conditioner and installed
into awindow in accordance with the operating modes that you wish to set. Install
the flexible hose B4 when you wish to select the operating modes: cooling and
dehumidification.
Extend the flexible hose B4 to the required length. Fix the inlet hose adaptor B5 on
to the end of the flexible hose B4. Place it over the air outlet A10 and fix it on the air
outlet A10 by moving it down.
Fix the outlet hose adaptor B6 on to the second end of the flexible hose B4.
Note:
Avoid excessive bending of the hose – see fig. E. To ensure the proper
operation of the portable air conditioner, it is important not to overload
the hose, or to bend it unnecessarily. Excessive loading or bending may
damage the hose.
Installation of flexible hose into aslide window
The window insert is designed to be compatible with the majority of sliding
windows (vertical and horizontal). Nevertheless, for certain types of slide windows it
may be necessary to modify the installation procedure described below.
Open the sliding window sash and place the window insert into the window. Adjust
the dimensions of the window insert to the width of the window (on a vertical
slide window) / height of the window (on ahorizontal slide window). If necessary,
cut away apart of the window insert if the window is too small. Close the sliding
window sash to the window insert. Insert the flexible hose B4 with attached outlet
hose adaptor B6 into the hole in the window insert.
Installation of flexible hose using the sealing kit
The sealing kit B2 is suitable for tilt-open, sash and roof windows. The textile
protection is easy to install in the window using the Velcro. Open the window
and into the created crevice install the tape of Velcro. We recommend that you
thoroughly degrease the location where you will be attaching the tape of Velcro
using an appropriate cleaning agent. Remove the protective paper strip and stick
the tape on to the window frame.
To be able to insert the flexible hose B4, the textile protection is fitted with an
integrated zip. Open the zip in such alocation that will enable you to easily insert
the flexible hose B4.
It is not necessary to remove the sealing kit B2 from the window when not using the
portable air conditioner. The window can be still closed.
OPERATION OF THE PORTABLE AIR CONDITIONER
A. CONTROL PANEL
Insert the power plug into apower socket. Now, the portable air conditioner sets
itself to the stand-by mode.
Turning the portable air conditioner on and off
To turn on the portable air conditioner, press the button C14. Press it again to
switch the portable air conditioner to the stand-by mode.
Note:
Never turn off the portable air conditioner by pulling the power cord out
of the power socket. Turn off the portable air conditioner using the
button C14, wait afew minutes and then pull out the power cord.
OPERATING MODES
1. Cooling mode
Repeatedly press the button C13 until the cooling indicator C6 is lit. Use the
+/- buttons to set the desired temperature. You can set the temperature in the range
from 18 to 32°C. The set temperature is shown on the display C5.
Use the button C10 to set the fan speed in the following order: High (high
speed) – Low (low speed). Each time the button is pressed, the respective indicator
will be lit on the control panel A1.
2. Fan mode
Repeatedly press the button C13 until the fan indicator C8 is lit. Use the
button C10 to set the fan speed in the following order: High (high speed) – Low (low
speed). Each time the button in pressed, the respective indicator will be lit on the
control panel A1 and at the same time, the respective graphic symbol ( symbol
for high speed; symbol for low speed) will be lit on the display C5. In this mode,
it is not possible to set the temperature, nor it is necessary to connect the flexible
hose B4 to the portable air conditioner.
3. Dehumidification mode
Ensure the flexible hose B4 is connected to the air conditioner. Repeatedly press
the button C13 until the dehumidification indicator C7 is lit. The display C5
shows . In this mode, it is not possible to set the temperature or fan speed. The
fan speed is automatically set.
FUNCTIONS OF THE PORTABLE AIR CONDITIONER
1. Automatic turn-on function
Turn the portable air conditioner on by pressing the button C14. Use the
button C13 to select the operation mode in which you wish to turn the portable
air conditioner on. Use the +/- buttons to set the desired temperature and use the
button w to set the fan speed as required. Press the button C14 to turn the
portable air conditioner off.
Now, press shortly once button C9. Press the button C9 repeatedly to set
the time after which the portable air conditioner will turn on automatically. You can
set the time of the automatic turn-on function in the range from 1 up to 24 hours.
After afew seconds, the set time will be saved in the air conditioner memory and the
automatic turn-on indicator will be lit on the display C5. Once the set time elapses,
the portable air conditioner will turn on automatically.
If you press button C9 or button C14 after the automatic turn-on function is
set, the setting will be automatically cancelled.
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sencor SAC MT7007C wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info