EN Humidier
User'smanual
Prior to using this appliance, please read the user'smanual thoroughly, even in cases,
when one has already familiarised themselves with previous use of similar types of
appliances. Only use the appliance in the manner described in this user'smanual. Keep
this user'smanual in asafe place where it can be easily retrieved for future reference.
We recommend saving the original cardboard box, packaging material, purchase
receipt and responsibility statement of the vendor or warranty card for at least the
duration of the legal liability for unsatisfactory performance or quality. In the event of
transportation, we recommend that you pack the appliance in the original box from
the manufacturer.
HOW THE HUMIDIFIER WORKS AND ITS FEATURES
A humidier eectively increases indoor air humidity and thereby improves air
quality and has apositive eect on human health. It acts preventively against drying
out of the mucous membrane in the respiratory tract and prevents respiratory
illnesses. Its use is recommended primarily during the heating season, when, as
arule, indoor air is predominantly dry.
The SHF 2050BL / SHF 2051GR Humidier works on the principle of ahigh frequency
ultrasound oscillator. Thanks to this technology, it produces cold steam and does
not aect the temperature in the room. The humidifying performance is adjustable
and essential oils can be used to create a pleasant indoor atmosphere. With
a humidifying performance of 250 ml/h, it is suitable for rooms up to an area of
30 m2. Its large 4-litre water tank guarantees an operating time of up to 16 hours per
single rell. When there is an insucient amount of water in the tank, asignal is lit
and, at the same time, aprotective function is activated, which automatically shuts
o the humidier to prevent its damage. The automatic shut o is also activated,
when the water tank is removed during operation.
DESCRIPTION OF THE HUMIDIFIER
A1 Steam exhaust nozzle, 360° pivot
A2 Essential oil holder
A3 Steam outlet
A4 4-litre water tank
A5 Plug of the water tank lling
opening with awater release switch
A6 Water holder
Water is pumped into the water
holder from the water tank.
A7 Air exhaust opening
A8 Nebulizer
asurface where water is converted
into cold steam (mist).
A9 Base unit
A10 Light indicator of operation and low
water level in water holder
A11 Humidifying performance control
serves to turn o the appliance
and to set the output.
A12 Ventilation openings
OPERATING LOCATION OF THE HUMIDIFIER, ITS ASSEMBLY
AND FILLING THE WATER TANK
1. Always place the humidier on an even, dry and stable surface at a minimum
distance of:
60 cm from the oor;
30 cm from walls or sides of furniture;
200 cm from electrical and electronic devices or materials sensitive to moisture
to prevent their damage by the eects of increased humidity.
2. Make sure that the humidier is turned o and disconnected from the power socket.
Remove the nozzle A1 and lift the water tank A4 o the base unit A9. Turn it upside
down and turn anticlockwise to unscrew the plug of the lling opening A5 and
remove it.
3. Fill the water tank A4 with clean cold tap water. After lling up the water tank A4,
properly secure the plug A5 by turning it clockwise all the way. Turn the water tank
A4 upside down with the plug A5 facing downwards and place it back on to the
base unit A9 so that both parts t into each other properly. When the water tank A4
is placed on the base unit A9, water will start to be pumped into the water holder A6.
Attention:
The water tank A4 is lled with water up to 40 °C.
If you need to move the humidier, be especially careful not to spill the
water contained in the water holder A6.
4. After opening it, you may add afew drops of essential oil into the essential oil holder
A2 as shown in gure B1. Before using any essential oils, please ask the vendor or
an expert about its eects and correct dosage. Do not add anything other than
essential oils to the essential oil holder A2. After adding essential oil, close the
essential oil holder A2, see gure B2.
5. Place the nozzle A1 into the steam outlet A3.
USING THE HUMIDIFIER
1. Check that the humidier is correctly assembled. Connect the power cord to
apower socket. Turn the control dial A11 clockwise to turn on the humidier. The
indicator A10 will be lit green. The humidier will start producing cold steam within
a few moments. Ensure that during operation that the steam is not directed at
furniture or items sensitive to moisture. The steam exhaust direction can be set by
turning the nozzle A1 to the required angle.
2. Use the control dial A11 to increase or decrease steam output intensity during
operation. Turn the control dial A11 clockwise to increase steam output, turn it in
the opposite direction to reduce steam output. If you ll the water tank A4 up to the
edge, the expected operating time is up to 16 hours with the steam output set to
maximum intensity.
Attention:
If the humidier was transported at a temperature below the freezing
point, rst put it into room temperature and wait approx. 30 minutes before
turning it on.
Use the humidier at an ambient temperature of 5 to 40 °C and at arelative
humidity of up to 60 %. In the event that the ambient temperature falls
below 0 °C, turn the humidier o and remove the water inside the water
tank A4 and the water holder A6, to prevent it from being damaged.
Do not lift the water tank A4 out of the base unit A9 or touch the nebulizer
A8 while the humidier is running. For the event that the water tank A4 is
removed during operation, the humidier is equipped with a protective
automatic shut o function.
3. If the water level in the water holder A6 runs low, the indicator A10 will be lit red and
the humidier will automatically stop producing steam. This is asafety function to
prevent the nebulizer A8 from being damaged.
If necessary, ll up the water according to the instructions in point 2 and 3 in chapter
Operating location of the humidier, its assembly and lling the water tank. Then
you can start the humidier again.
4. To turn o the humidier, turn the control dial A11 anticlockwise all the way. The
indicator A10 will turn o. Disconnect the humidier from the power socket and
clean it out according to the instructions contained in the chapter Cleaning and
maintenance.
CLEANING AND MAINTENANCE
Before cleaning the humidier, turn it o and disconnect it from the power socket.
Please adhere to the following instructions relating to the cleaning and maintenance
of the humidier. Otherwise its performance may be negatively aected and
undesirable microorganisms may multiply inside the humidier.
Clean after every use
Remove the nozzle A1 from the steam outlet A3. Then take out the essential oil
holder A2 and clean out any remaining essential oil, and then put it back in its place.
Take the water tank A4 o the base unit A9, carry it to akitchen sink, turn it upside
down and open the lock A5. Remove any remaining water from it via the lling
opening, rinse it out with clean water and dry the surface using ane wiping cloth.
Finally, attach the lock A5 to the water tank A4, and insert the nozzle A1 into the
outlet A3.
Remove the water from the water holder A6 and wipe it dry using ane clean cloth.
Thorough cleaning (once per week)
Pour approximately 100 ml of vinegar into the water holder A6 and allow it to act for
15 minutes. Using abrush with gentle bristles, remove the limescale deposits in the
water holder A6 and the nebulizer A8. Then clean out all the remaining limescale
and vinegar using acloth dampened in clean water and wipe dry.
Thoroughly clean out the essential oil holder A2 under running water or using
adampened cloth and then put it back in its place.
Attention:
Do not leave water in the water tank A4 or in the water holder A6 for longer
than aweek.
Do not touch the nebulizer A8 with sharp objects in order not to damage it.
Clean the outer surface of the humidier as required using ane clean cloth lightly
dampened in lukewarm water.
Do not submerge the base unit A9 in water or rinse it under running water. For
cleaning, do not use abrasive cleaning products, solvents, etc. Otherwise, this could
damage the surface of the appliance.
TROUBLESHOOTING
Problem Possible cause Solution
The indicator light
A10 is not lit and
the humidier is not
producing steam.
The humidier is
connected to afaulty
power socket or is not
connected to apower
socket at all.
Connect the humidier to
aworking power socket and use
the control dial A11 to set the
required steam output intensity.
The indicator light
A10 is lit red.
There is not enough
water in the water
holder A6.
Turn o the humidier and
disconnect it from the power
socket. Fill up the water tank A4
with cold clean water. Assemble the
humidier, connect it to apower
socket and start it again.
An odour can be
sensed in the steam.
The odour may be
sensed when the
humidier is used for
the rst time.
Open the water tank plug A5 and
allow the water tank A4 to ventilate
for at least 12 hours.
There is dirty water in
the water tank A4 /
water holder A6.
Turn o the humidier and
disconnect it from the power
socket. Remove the water from
the water tank A4 and the water
holder A6. Clean everything. Fill up
the water tank A4 with cold clean
water. Connect the humidier to
apower socket and start it again.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sencor SHF 2050 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Sencor SHF 2050

Sencor SHF 2050 Bedienungsanleitung - Holländisch - 6 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info