759452
7
Zoom out
Zoom in
Vorherige Seite
1/8
Nächste Seite
- 7 - 09/2020
Copyright © 2020, Fast ČR, a.s.
EN Bagless vacuum cleaner
User's manual
DESCRIPTION OF THE VACUUM CLEANER
A1 Vacuum cleaner carry handle
A2 Dust container release handle
A3 Dust container lid
A4 Dust container
A5 Hose connection hole
A6 Cord winding button
A7 Suction power control knob
A8 Parking position
A9 On/Off button
A10 Outflow filter protective grille
A11 Outflow filter
A12 Rubber coated wheels
A13 Holder
A14 Sliding flap for air suction
A15 Telescopic tube
A16 Telescopic tube position lock
A17 Combination floor nozzle
A18 Flap position for vacuuming carpets
A19 Flap position for vacuuming hard
(smooth) floors
A20 Stopper for the parking position
A21 Hose
A22 Clip
A23 Hose end
A24 Long flexible crevice nozzle
A25 Combination crevice nozzle with an
extensible brush
ASSEMBLY
Inserting the hose into the air suction hole on the vacuum cleaner.
Press both the clips on the end of the hose and insert it into the air suction hole A5
on the vacuum cleaner until you hear a "click". The hose A21 is now secured in the
correct position.
Attach the holder to the telescopic tube:
Make sure to place the holder with the hose on the wider part of the telescopic
tube A15.
Attach the floor nozzle to the telescopic tube:
Make sure that the floor nozzle A17 is attached to the narrower part of the
telescopic tube A15.
Adjust the length of the telescopic tube:
Adjust the length of the telescopic tube A15 as required – disengage and hold the
clip A16 on the tube in the direction shown by the arrow and adjust the length
of the tube A15 as required. Then release the clip A16 and slide out the tube A15
slightly forward until you hear a "click". The telescopic tube A15 is now securely
locked in position.
USING THE VACUUM CLEANER
Connecting the vacuum cleaner to the power grid
Wind out the required length of the power cord by pulling on the power plug. Insert
the power plug into a power socket.
Attention:
The yellow marking on the power cord warns you that the power
cord is close to its end. Do not pull the cord farther than the red
marking.
Adjusting the floor inlet nozzle according to the floor surface.
You may set the inlet nozzle according to the floor surface by adjusting the inlet flap:
If you want to vacuum carpets, move the flap to retract the bristles.
If you want to vacuum hard and smooth surfaces, move the flap to extend the
bristles.
Turning the vacuum cleaner on and off
To turn on the vacuum cleaner, press the On/Off button A9. To turn off the vacuum
cleaner, press the button A9 again.
Adjusting the suction power
Suction can be controlled using the control knob A7. Turning clockwise (towards
MAX) increases the power of the vacuum cleaner, turning anticlockwise (towards
MIN) reduces the power. In a smaller range, you may regulate suction power using
the mechanically sliding flap A14 on the hose handle.
Tips
Use the maximum suction power when vacuuming carpets or floors with a hard
surface. Use the reduced strength when vacuuming upholstery, window curtains,
etc.
If the hose holder becomes blocked when vacuuming, disconnect it from the
telescopic tube and also disconnect the hose from the vacuum cleaner body. Then
place the holder inside the suction hole on the vacuum cleaner body and vacuum
the stuck dirt out.
Temporary interruption of the vacuuming process
If you wish to temporarily stop vacuuming, you can use the parking position A8
on the vacuum cleaner, into which the stopper A20 on the floor nozzle is inserted.
Attention:
Do not move the vacuum cleaner from place to place if the hose
is in the parked position! The stopper on the floor nozzle could
brake off.
Ending the vacuuming process
When you o finish vacuuming, switch the vacuum cleaner off by pressing the On/
Off button A9 and then disconnect the power cord plug from the power socket.
To wind the power cord back into the vacuum cleaner, press and hold the winding
button A6 with one hand and guide the power cord with the other.
Tips
If the winding process stops and part of the power cord is still outside, release the
winding button A6 and pull the cable out again by about 50 cm and then press and
hold the winding button A6 again and repeat the winding process.
USING THE ACCESSORIES
The combination floor nozzle A17 for hard floors ensures perfect and yet gentle
vacuuming of smooth hard surfaces thanks to the brush being from 100 % natural
bristles. It can be used to vacuum floors that are sensitive to scratching such as
wooden or floating floors, marble floors, tiles, linoleum, etc.
The long flexible crevice nozzle A24 serves to vacuum very hard-to-reach places
anywhere in your car.
The crevice nozzle A25 is suitable for vacuuming hard to reach places (e.g. window
frames, libraries, upholstery corners, joints, etc.).
CLEANING AND MAINTENANCE
Attention:
Before cleaning, disconnect this appliance from the power source.
Emptying the dust container
Regularly empty out the dust container A4 as otherwise as the air flow and the suction
power of the vacuum cleaner are reduced. Nevertheless, it is recommended to always
empty out the dust container A4 when you have finished vacuuming.
1. Take out the hose A21.
2. Grasp the dust container A4 by the handle A2 and pull it out upwards.
3. Take the dust container A4 above a waste bin and press the button for releasing
the bottom of the dust container – see fig. B, to tip the dirt and dust out of it. If it is
heavily soiled you may wash the entire container under running lukewarm water.
However, before doing this, it is necessary to remove the filtration unit!
4. Close the bottom of the dust container A4 and insert it into the vacuum cleaner.
Attention:
Make sure that all parts are completely dry before reinserting the
dust container A4 back into the vacuum cleaner.
Replacement and cleaning of the filtration unit with the HEPA filter
It is recommended to regularly clean and replace the filtration unit with the HEPA filter
to ensure that the vacuum cleaner remains in reliable working condition.
1. Pull the dust container A4 out of the vacuum cleaner.
2. Carefully release the clip on the lid A3 – see figure C1.
3. Tilt open the lid and remove the HEPA filter with the foam pre-filter – see figure C2.
Wash both filters under running lukewarm water and if necessary replace them with
new ones.
4. Carefully remove the filtration unit from the dust container A4 and wash it together
with the dust container A4 in lukewarm water. Allow everything to dry thoroughly.
5. Then assemble the filtration unit and insert it into the dust container A4. Then insert
the foam pre-filter and finally the HEPA filter – see figure C3.
6. Place the dust container A4 back into the vacuum cleaner.
Attention:
Never insert the filters back into the vacuum cleaner if they are
wet or damp! Always wait until they are thoroughly dry.
Replacing the outflow filter
First remove the grille of the outflow filter A10 by pulling it away from the vacuum
cleaner in the location of both safety clips.
Then remove the outflow filter A11 and replace it with a new one.
After reinserting the filter A11, put on the grille of the outflow filter A10 and click
it in behind both the clips.
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sencor SVC 1025 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info