RS8711ETC 2/2
3. there will have 1Hz flashing during setting
4. press “clock” to confirm the setting, and enter the next setting state
5. press “Up” one time, the setting will go ahead for one step; hold the key for 2 seconds, it will run forward by 8 steps/second.
6. press “Down” one time, the setting will backward for one step; hold for 2 seconds, it will run back by 8 steps/second.
7. moon phase is changed accordingly time changed.
8. the system will exit automatically if no key is operated in 8 seconds.
3.4 Alarm set
1. hold “Alarmkey for 2 second to enter into alarm setting
2. the sequence of alarm setting: Hour Minute exit
3. there will have 1Hz flashing during setting
4. press “Alarm” to confirm the setting, and enter the next setting state
5. press “Up” one time, the setting will go ahead for one step; hold the keys for 2 seconds, it will run forward by 8 steps/seconds.
6. press “Down” one time, the setting will backward for one step; hold for 2 seconds, it will run back by 8 steps/second.
7. the system will exit automatically if no key is operated in 8 seconds.
3.5 Temperature alarm setting
1. hold”ALERT”2 second into ALERT setting
2. setting sequence :upper limited lower limitexit
3. press”CHANNEL”key when setting upper limited and lower limited to change different channel.
4. default of upper limited is:+70°C ,lower limited is -50°C
5. there will have 1Hz flashing during setting
6. press”ALERT”key confirm the end of setting then enter next item setting
7. press “Up” one time, the setting will go ahead for one step; hold the keys for 2 seconds, it will run forward by 8 steps/seconds.
8. press “Down” one time, the setting will backward for one step; hold for 2 seconds, it will run back by 8 steps/second.
9. the system will exit automatically if no key is operated in 8 seconds.
10. Alert will automatically turn on when setting is finish.
3.6 RCC receiving function:
1. How to enter RCC receiving status:
a. It will enter RCC receiving state automatically 3 minutes after powering ON or resetting.
b. It enters RCC receiving automatically at2:00, 3:00, 4:00, 5:00 everyday.
c. Press “Down” or “UP” key for 2 seconds to enter RCC receiving status forcibly.
2. RCC receiving time is 7 minutes.
3. When it is receiving signals, press “Down” or “UP” key will exit RCC receiving status, pressing any other key will have no effect.
4. When DST is able and is receiving the signal, it will display the symbol of sun on the LCD, showing that it enters the DST system, and the
time will be 1 hour faster.
5. When the RCC symbols display fully, the relative RCC icon will be OFF if the present time is changed.
. Function and effect
4.1 The receiving function of RF
1. after installing the battery and checking temperature/humidity, it will enter RF receiving state automatically for 3 minutes.
2. under normal display mode, hold the “Channel” key for 2 seconds to clear out the channel information
3. if there is no effective signal with same ID code received for the current channel in 35 minutes, the temperature of that CH will shows “--.-“.
4. the temperature display will resume back when the correct signal is received again
4.2 The function of alarm
1. the BUZZER will ring for 2 seconds as below:
a. 0 – 10 sec.: one “beep” per second
b. 10 – 20 sec.: two “beep” per second
c. 20 – 30 sec.: four “beep” per second
d. after 30 sec.: “beep” continuously
2. when ringing, click “SNZ/LIGHT” key once to enter into 5 minutes snooze states, exit if any other key is clicked.
4.3 The function of temperature and humidity
1. the indoor temperature display range: 0 -- +50 (32F -- +122F)
2. the indoor temperature proposed operating range: 0 -- +40 (32F -- +104F)
3. the outdoor temperature display range: - 50 -- +70 (-58F -- +158F)
4. the outdoor temperature proposed operating range: -5 -- +45 (23F -- +113F)
5. the temperature resolution: 0.1
6. the indoor humidity range: 20% --- 95%
7. the humidity resolution: 1%RH
8. sampling period: 12 seconds.
9. the temperature and hygrometer sampling will be held when the alarm is ringing
10. the RF Transmission Frequency: 433.92MHz
11. No. of Remote unit: Up to 3units
4.4 The function of weather forecast
1. weather icons for 4 states: sunny semi-sunny cloudy rainy
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sencor SWS 30 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info