Zoom out
Zoom in
Vorherige Seite
1/8
Nächste Seite
3 1/2 DIGITS DIGITAL MULTIMETER
600.005
Gebruiksaanwijzing
Mode d’Emploi
Gebrauchsanleitung
Brugsanvisning
Instruction Manual
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Inhalt der Seiten


  • Page 1

    3 1/2 DIGITS DIGITAL MULTIMETER
    600.005

    Gebruiksaanwijzing
    Mode d’Emploi
    Gebrauchsanleitung
    Brugsanvisning
    Instruction Manual



  • Page 2

    Read the Users Manual thoroughly before use.
    SAFETY INFORMATION
    The digital multimeter has been designed according to IEC-1010
    concerning electronic measuring instruments with an over voltage
    category (CATI) and pollution degree 1.
    ELECTRICAL SYMBOLS
    AC (Alternating Current)
    DC (Direct Current)
    Important safety information. Refer to the manual.

    Dangerous voltage may be present.
    Earth ground
    Fuse
    Conforms to European Union directives

    Double insulated
    Do not attempt to make any repairs yourself. This would invalid your warranty.
    Do not make any changes to the unit. This would also invalid your warranty.
    The warranty is not applicable in case of accidents or damages caused by
    inappropriate use or disrespect of the warnings contained in this manual.
    SkyTronic UK cannot be held responsible for personal injuries caused by a
    disrespect of the safety recommendations and warnings. This is also applicable to
    all damages in whatever form.



  • Page 3

    WARNING
    To avoid possible electric shock or personal injury, follow these
    guidelines:

    Do not use the meter if it is damaged. Before you use the
    meter, inspect the case. Pay particular attention to the
    insulation surrounding the connectors.

    Inspect the test leads for damaged insulation or exposed
    metal. Check the test leads for continuity. Replace damaged
    test leads before you use the meter.

    Do not use the meter if it operates abnormally. Protection
    may be impaired. When in doubt, have the meter serviced.

    Do not operate the meter around explosive gas, vapour, or
    dust.

    Do not apply more than the rated voltage, as marked on the
    meter, between terminals or between any terminal and earth
    ground.

    Before use, verify the meter's operation by measuring a
    known voltage.

    When servicing the meter, use only specified replacement
    parts.

    Use with caution when working above 30V ac rms, 42V
    peak, or 60V dc. Such voltages pose a shock hazard.

    When using the probes, keep your fingers behind the finger
    guards on the probes.

    Connect the common test lead before you connect the live
    test lead. When you disconnect test leads, disconnect the
    live test lead first.

    Remove the test leads from the meter before you open the
    battery door.

    Do not operate the meter with the battery door or portions of
    the cover removed or loosened.

    To avoid false readings, which could lead to possible electric
    shock or personal injury, replace the batteries as soon as the
    low battery indicator (
    ) appears.



  • Page 4

    CAUTION
    To avoid possible damage to the meter or to the equipment under
    test, follow these guidelines:

    Disconnect circuit power and discharge all high-voltage
    capacitors before testing resistance, continuity, diodes, or
    capacitance.

    Use the proper terminals, function, and range for your
    measurements.

    Before measuring current, check the meter’s fuses and turn
    power OFF to the circuit before connecting the meter to the
    circuit.

    Remove test leads from the Meter before opening the Meter
    case.
    MAINTENANCE

    Before opening the case, always disconnect the test leads
    from all live circuits.

    For continue protection against fire, replace fuse only with
    the specified voltage and current ratings: F 250mA/250V
    (Fast Blown) ø5 x 20.

    Periodically wipe the case with a damp cloth and mild
    detergent. Do not use abrasives or solvents.
    GENERAL SPECIFICATIONS
    Display: 3 1/2 digits LCD, Max. reading 1999
    Over range indicate: Symbol “1” appear on the LCD
    Zero adjustment: Automatic
    Low battery indication: Symbol “
    ” appears on the LCD
    Power: 12V battery
    Dimension: 100mm(L) x 50mm(W) x 20mm(D)
    Weight: 60g (including battery)
    TECHNICAL SPECIFICATIONS
    Accuracy is specified for a period of one year after calibration and
    at 18ºC~28ºC(64ºF~82ºF) with relative humidity up to 75%.
    Accuracy specifications take the form of:
    ±([% of Reading]+[Number of Least Significant Digits])



  • Page 5

    DC VOLTAGE
    Range
    Accuracy
    200mV
    2V
    ±(0.8%+1)
    20V
    200V
    500V
    ±(1%+1)
    Input impedance: 1MΩ for all ranges.
    AC VOLTAGE
    Range
    Accuracy
    200V
    ±(1.5%+10)
    500V
    Input impedance: 452KΩ
    Frequency range: 50Hz~200Hz
    DC CURRENT
    Range
    2mA
    20mA
    200mA
    RESISTANCE
    Range
    200Ω
    2KΩ
    20KΩ
    200KΩ
    2MΩ

    Accuracy
    ±(2%+2)
    ±(1%+2)

    Accuracy

    ±(1%+3)

    Resolution
    100•V
    1mV
    10mV
    100mV
    1V

    Resolution
    100mV
    1V

    Resolution
    1µA
    10µA
    100µA

    Resolution
    0.1Ω
    1Ω
    10Ω
    100Ω
    1KΩ



  • Page 6

    DIODE AND AUDIBLE CONTINUITY TEST
    Range
    Description
    Test Condition
    The approx. forward
    The forward DC current
    voltage drop of the diode
    is approx. 1mA, the
    will be displayed on the
    reversed DC voltage is
    LCD.
    approx. 2.8V.
    If the resistance of the
    circuit under test is less
    Open circuit voltage is
    than 40Ω, the built-in
    approx. 2.8V.
    buzzer will sound.
    TRANSISTOR TEST
    Range
    hFE
    PNP & NPN
    0~1000

    Test Current
    1b=10µA

    Test Voltage
    Vce=2.8V

    OPERATING INSTRUCTION
    DC VOLTAGE MEASUREMENT
    1.
    Connect the red test lead to the “VΩ” jack and the black test
    lead to the “COM” jack
    2.
    Set the range switch to the desired “ ” range. If the voltage
    to be measured is not known beforehand, set the range
    switch to the highest range and then turn down range by
    range until satisfactory resolution is obtained.
    3.
    Connect the test lead to the source or load to be measured.
    4.
    Read the voltage value displayed on the LCD.
    AC VOLTAGE MEASUREMENT
    1)
    Connect the red test lead to the “VΩ” jack, and the black test
    lead to the “COM” jack.
    2)
    Set the range switch to the desired “ ” range. If the
    voltage to be measured is not known beforehand, set
    the range switch to the highest range and then turn down
    range by range until satisfactory resolution is obtained.
    3)
    Connect the test lead to the source or load to be measured.
    4)
    Read the voltage value displayed on the LCD.



  • Page 7

    DC CURRENT MEASUREMENT
    1)
    Connect the red test lead to the “mA” jack and the black test
    lead to the “COM” jack.
    2)
    Set the range switch to the desired “ ” range. If the
    current to be measured is not known beforehand, set
    the range switch to the range and then turn down range by
    range until satisfactory resolution is obtained.
    3)
    Open the circuit in which the current is to be measured, and
    connect test leads in series with the circuit.
    4)
    Read the current value displayed on the LCD.
    RESISTANCE MEASUREMENT
    1)
    Connect the red test lead to the “VΩ” jack and the black test
    lead to the “COM” jack.
    2)
    Set the range switch to the desired “Ω” range.
    3)
    Connect the test leads to the circuit to be measured.
    4)
    Read the resistance value displayed on the LCD.
    DIODE TEST
    1)
    Connect the red test lead to the “VΩ” jack and the black test
    lead to the “COM” jack.
    2)
    Set the range switch to the desired “
    ” range.
    3)
    Connect the red test lead to the anode of the diode to be
    tested and the black test lead to the cathode of the diode.
    The approximate forward voltage drop of the diode will be
    displayed on the LCD. If the connection is reversed, only
    figure “1” will be shown.
    TRANSISTOR TEST
    1)
    Set the range switch to the “hFE” range.
    2)
    Determine whether the transistor to be tested is NPN or
    PNP, and locate the E, B, C leads. Insert the leads into the
    proper holes of the hFE socket on the front panel.
    3)
    Read the approximate hFE value at the test condition of
    base current 10µA and Vce 2.8V.



  • Page 8

    AUDIBLE CONTINUITY TEST
    1)
    Connect the red test lead to the “VΩ” jack and the black test
    lead to the “COM” jack.
    2)
    Set the range switch to the “ ” range.
    3)
    Connect the test leads to the two terminals of the circuit to
    be tested. The resistance is less than about 40Ω, the built-in
    buzzer will sound.
    Battery & Fuse Replacement
    ” appears on the LCD, it indicates that the battery should be
    If “
    replaced. To replace the battery, open the case, replace the
    exhausted battery with the ratings specified: 12V, and then close
    the case.
    The fuse rarely needs to be replaced and is blown as a result of the
    operator's error. To replace the fuse, open the case, replace the
    blown fuse with the ratings specified: F 250mA/250V, and then
    close the case.






Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Skytronic 600.005 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Holen Sie sich Ihr Benutzerhandbuch per E-Mail

Geben Sie Ihre E-Mail-Adresse ein, um das Handbuch zu erhalten von Skytronic 600.005 in der Sprache / Sprachen: Englisch als Anhang in Ihrer E-Mail.

Das Handbuch ist 0,12 mb groß.

 

Sie erhalten das Handbuch in Ihrer E-Mail innerhalb von Minuten. Wenn Sie keine E-Mail erhalten haben, haben Sie wahrscheinlich die falsche E-Mail-Adresse eingegeben oder Ihre Mailbox ist zu voll. Darüber hinaus kann es sein, dass Ihr ISP eine maximale Größe für E-Mails empfangen kann.

Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info