User manual
SYGONIX
radiator thermostat HT100
Art.-No. 1377979
Controls
Heating Time
Batterieverbrauch
Vacation Function
Comfort Temperature
Economy Temperature
Open Window
Function
keylock
AKKU
AKKU
Attention
MENU
MODE
PROG TEMP ZEIT FENS RES
ADAPURLA INST OFFS VERS
Menu structure overview
AUTO/MANU
WHEEL
PROG
DAY 1
TEMP
Comfort temperatur AUS/EIN
ZEIT
year
FENS
sensibility
RES
Reset factory settings
ADAP
Actuator travel adjustment
URLA
Holiday period Profile
INST
Mounting position
OFFS
Temperature fluctuation -/+5C°
VERS
Software version
MODE
Set-back temperature AUS/EIN
month day hours minute
time (minutes)
1. Remove battery cover/Insert batteries
2. Enter Date and Time
3.a Mounting on the radiator without adapter
Valve - Radiator Thermostat HT100
1. 2.
OKOKOK
Mounting
No adapter is required for the following valves:
Heimeier, Junkers Landys+Gyr, MNG, Honeywell Braukmann, since these have thread
dimensions of M30 x 1.5 mm. Adapters for Danfoss RAV (pin must be put on the valve
tappet) Danfoss RA and Danfoss RAVL are enclosed.
An adapter is required for the following valves:
Herz M28 x 1,5 mm, Comap M28 x 1,5 mm, Vaillant 30,5 mm, Oventrop M30 x 1,0 mm,
Meges M38 x 1,5 mm, Ondal M38 x 1,5 mm, Giacomini 22,6 mm, Rossweiner M33 x 2,0
mm, Markaryd M28 x 1,0 mm, Ista M32 x 1,0 mm, Vama M28 x 1,0 mm, Pettinaroli
M28 x 1,5 mm, T+A M28 x 1,5 mm oder Gampper 1,2,6.
E1
If E1appears in the display then the installation was
not successful. Look at the Support Table.
4. Adapt
3.b Mounting on the radiator with adapter
Valve – Adapter – Radiator Thermostat HT100
Start ready.
1. 2.
ADAP
OK
Pull the battery cover, in the recess on the underside of the housing, upwards. Insert two
batteries of type AA/Mignon with correct polarity (observe plus / + and minus / -, see imprint
in the battery compartment). Pay attention to the correct position of the batteries to avoid
contact interference. Close the battery compartment again. Due to the lower output voltage
of batteries (batteries = 1.5V, rechargeable batteries = 1.2V) there may be a very short period
of operation. We therefore recommend to use high quality alkaline batteries for a long and
safe operation.
• For safety and licensing (CE) reasons, unauthorized conversion and/or
modification of the product is prohibited. NEVER disassemble it.
• The product is not a toy, it does not belong in children‘s hands.
• The product is only suitable for indoor use, it must not get damp or wet.
• Do not carelessly leave packaging material lying around.
• It could be a dangerous toy for children.
• Be careful when using the product. Knocks, blows or even a
fall from a low height can damage it.
• Should you have any questions that are not answered in this manual,
please contact us or another professional.
• Keep batteries out of the reach of children. Do not let batteries lying
around openly as there is the danger of them being swallowed by child-
ren or pets. If swallowed, consult a doctor immediately!
• Leaking or damaged batteries can cause burns on contact with skin,
therefore use suitable protective gloves when handling them. Leaking
battery fluids are chemically very aggressive. Objects or surfaces which
come into contact with them, can sometimes be massively damaged.
Keep batteries at a suitable location.
• Batteries must not be shorted, disassemble or thrown into the fire.
Risk of explosion!
• Conventional non-rechargeable batteries cannot be recharged,
Risk of explosion!
• Do not mix batteries with different state (e.g., full and half-full
batteries. Always replace the whole set of batteries.
• When inserting the batteries pay attention to the correct polarity
(Note: Plus / + and minus).
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK OK
OK
OK OK
OK
OK OK
0-6
INSTPREP
dd:mm
yyyy
hh:mm
RAVRA RAVL
RAV Pin
Bold for
Adapter
MENU OK
Mo Di Mi Do Fr Sa So
:
AUTO
MANU
02461218
www.sygonix.com
Basic Operating Modes
MANU mode: In the MANU Mode HT100 regulates to the set temperature by hand.
AUTO Mode: HT100 changes in the AUTO Mode according to the set
Time program between two temperatures.
The heating and economy times can be specified via the adjustable time program.
A maximum of 8 switch points (4 heating and 4 economy times) may be set per day.
The Radiator Thermostat HT100 has the following factory settings:
Heating time: Heating to comfort temperature
(factory setting: 1. heating time at 07:00 clock - 21 ° C)
Saving time: Reduction to economy temperature
(factory setting: 1. saving time at 22:00 clock - 16 ° C)
With the setting wheel a change in the room temperature is possible in the AUTO Mode
at any time, this will remain until the next switching point. The process can be terminated
prematurely by pressing the MENU button.
3.
INSTPREP
Button: Main Menu
Button: Confirmation
MENU
OK
Button: Timer function
MANU/AUTO
Modus
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

sygonix-ht100

Suche zurücksetzen

  • Temperatur manuell nicht veränderbar, obwohl Regler auf Manu eingestellt ist.Habe die Batterien gewechselt,das gesamte Teil abgemacht und wieder rangebaut,das Rädchen zum Verstellen dreht sich, aber die Zahl bleibt. Eingereicht am 11-3-2022 19:47

    Antworten Frage melden
  • Leider ist mir bei der Datum Einstellung am HT100 ein Fehler unterlaufen wie kann ich das Datum jetzt korrigieren oder alles wieder auf Null setzen .Ich habe schon die Batterien entfernt und wieder eingesetzt hat auch nichts gebracht .Die Anzeige bleibt gespeichert. Für eine Antwort wäre ich Ihnen dankbar Eingereicht am 28-12-2021 14:46

    Antworten Frage melden
  • Heizkörperthermostat HT100
    Die Bedienungsanleitung hat Lücken. Die Funktion Taste: Timerfunktion ist nicht beschrieben.
    Bei der Einstellung des Wochenprogramms wird nicht die eingestellte Uhrzeit angezeigt, sondern immer 7:00 und 24:00. Wo kann ich sehen wie die aktuell eingestellten Werte sind? Eingereicht am 12-1-2018 09:03

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sygonix HT100 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Sygonix HT100

Sygonix HT100 Bedienungsanleitung - Deutsch - 2 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info