15
Mounting the exhaust accessories.
The air conditioning system cools the air in the room where unit is placed. The absorbed heat
of the conditioned air, should be removed to outside the room where the unit is placed.
During cooling of hot air condenswater will be created. Much of the condensation will be
transported with the warm air to outside. At high humidity not all the condense will be
transported with the warm air to the outside, the water tank must regularly be emptied.
In the chapter "Condensate Drain" is this defined step by step.
There are several ways to transport warm air out of the room:
Attach the hose (No. 13) in the warm air outlet (No. 10) of the device. Hang the hose
out the window or a door. The cooling capacity will not be optimal because of warm
outside air will flow into the to cool area.
Drill a hole of 135 mm. diameter in the outer wall and enter the tubing through the
hole. The cool capacity is now optimal. Place the wall cover (No. 14) on the outside
of the wall. When the appliance is out of use, the cover (No. 15) can be placed on
the hole.
Place the window spacer in the open section of the window. Insert the hose (No. 13) into
the connection for the hose (No. 12). The cool capacity is optimal. Provide a maximum
distance of 36 cm. the device to the windows or exterior wall.
Make sure that the hose (No. 13) is not
kinked or that the air flow is obstructed.
Never extend the hose (No. 13).
16
Drainage
During cooling of hot air, condensation can be created. Much of the condensation will be
transported with the warm air outside. At high humidity not all the condense will be transported
with the warm air to the outside, the water tank must regularly be emptied.
If the condensation tank is full, the water full indicator light on the control panel (No. 2) will light
and a sound goes off, the machine stops automatically. The condensate tank has a maximum
capacity of 1.7 liter.
Turn the knob condensate drain (No. 12) off the spout. Place a container under the spout and
pull the rubber plug from the spout. The water flows out, when the bowl is full, insert the plug,
empty the sump and drain the rest of the water.
If the condensation must be removed continuously, place the condensation drain hose (No. 16)
on the spout. Do remove the rubber plug. The condensate drain hose can be extended with
another hose (not supplied). It can be connected to a drain or be led outside. Make sure this
hose does not go up.
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Tristar AC-5493 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info