756407
8
Zoom out
Zoom in
Vorherige Seite
1/12
Nächste Seite
8 EN
pyrometer TP10
Using the Save function
1. Repeatedly press the Mode button(3) until the MxMn Save
Avg menu is displayed.
2. Press the F2 button(5) to select Save.
ðThe Yes and Esc menus are shown on the display.
3. Press the F1 button (Yes) to save the measured value.
ðIt takes a short moment until the measured value will be
saved. The Saving indication(17) lights up on the
display. After that the display(1) shows the last
measured value again.
4. Or you press the F3 button(2) (Esc) to cancel the
operation.
ðThe last measurement will be displayed.
Using the Memory function
Using the Memory function you can call up values previously
saved with the Save function. The device comes with 30 internal
storage locations.
1. Repeatedly press the Mode button(3) until the Unit Mem Ɛ
menu is displayed.
2. Press the F2 button(5).
ðThe last saved value appears on the display.
ðThe Set menu will be displayed.
3. Either press F3 or F1 to view the saved values.
4. Press the F2 button(5) to select Del.
ðYou will now see the Yes All Esc menu.
5. If you want to delete a measured value (Yes), press the F1
button(4).
ðThe currently displayed measured value will be deleted.
6. If you want to delete all measured values (All), press the F2
button(5).
ðAll saved measured values will be deleted.
7. If you want to cancel the operation (Esc), press the F3
button(2).
ðThe Del menu is shown on the display.
8. Press the Mode button(3) to return into measuring mode.
Setting the temperature unit
1. Repeatedly press the Mode button(3) until the Unit Mem Ɛ
menu is displayed.
2. Press the F1button(4).
ðThe Unit °C °F menu is shown on the display.
3. Press the F2button(5) for °C or the F3button(2) for °F.
Setting the degree of emission
1. Repeatedly press the Mode button(3) until the Unit Mem Ɛ
menu is displayed:
2. Press the F3 button.
ðThe last saved value for the degree of emission appears
on the display.
ðThe Tab menu will be displayed.
3. Either press F3 or F1 to change the degree of emission.
ðThe value range is between 0.10 and 1.00.
ðThe selected setting will be saved automatically.
4. Press the F2 button to select a specific degree of emission.
ðThe Tab menu will be displayed.
ðA list with different degrees of emission will be
displayed:
Default 0.95
0x Aluminium 0.30
0x Brass 0.50
0x Copper 0.60
Paint 0.93
5. Either press F3 or F1 to select a specific degree of
emission.
6. Confirm the selection by pressing F2.
ðThe new degree of emission is set.
7. Press the Mode button(3) to leave the menu.
Info
A set specific degree of emission will not be stored in
the device, after it has been switched off. When being
switched on again, the device will always return to the
degree of emission previously set by hand.
De-/activating continuous measurements
Once the function is activated, the measurement will continue
until the function is terminated again. Within this time frame
settings can only be made in the following menu:
Lit Laser
1. Repeatedly press the Mode button(3) until the Lit Laser
menu is displayed.
2. Press the F1button(4).
ðContinuous measurement is activated.
ðThe On menu will be displayed.
3. Press the F1button(4).
ðContinuous measurement is deactivated.
ðThe Lit Laser menu is displayed.
Adjusting the display illumination
Ex works the display illumination is switched off. There are two
ways to adjust the display illumination.
Option 1: Via the menu. To do so, please proceed as follows:
1. Repeatedly press the Mode button(3) until the Lit Laser
menu is displayed.
2. Repeatedly press the F2 button(5) until the display is
illuminated as desired.
Option 2: Via the additional settings. To do so, please proceed
as follows:
1. Repeatedly press the Mode button(3) until the Hi Set Lo
menu is displayed.
2. Press the F2 button(5).
ðThe Set menu will be displayed.
3. Either press F3 or F1 to select the Backlight option.
4. Confirm the selection by pressing the F2button(5).
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Trotec TP10 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Trotec TP10

Trotec TP10 Bedienungsanleitung - Deutsch - 13 seiten

Trotec TP10 Bedienungsanleitung - Holländisch - 13 seiten

Trotec TP10 Bedienungsanleitung - Französisch - 13 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info