557896
1
Zoom out
Zoom in
Vorherige Seite
1/2
Nächste Seite
Flashing for short random
Flashing for long random
ET170 electronic programmable timer
OWNERS
MANUAL
Congratulations on your
purchase of a UPM timer.
Please take the time to
read and understand this
manual so you can begin
to enjoy the security and
energy saving benefits this
product has to offer.
FEATURES
! 20 ON/OFF settings
! Countdown timer
! 3 random functions
! 12/24 hour clock
! 15A, 1800W (resistive)
GETTING STARTED
battery installation
PROGRAM SETTINGS
COUNTDOWN TIMER RANDOM FUNCTION
disable program/master disable
TROUBLESHOOTING
1
2
1
2
remove the battery cover
from the back of the unit
place 2 AAA batteries between
terminals observing proper
polarity then replace cover
short/long random
programmable random
LCD display seems “frozen”.
Buttons won’t respond.
Timer loses programs when
unplugged.
Programmed ON/OFF times
don’t execute.
Programmed ON/OFF times
don’t execute at specified
times.
Press reset button to reset
timer.
Replace batteries.
Ensure that the program
disable feature is not enabled.
Ensure that the random
function is not enabled.
problem solution
TECHNICAL SPECIFICATIONS
Program: 20 programs
Ratings: 120V AC, 15A
Max Load: 1800W resistive; 600W tungsten
Min switching time: 1 minute
1
1
2
Program select with Program
1
Press On/Off to disable ( X )
3
For single disable select Program using Program
For master disable go to clock setting mode using Program
1
2
Press Random Mode
Set Program 20 to desired random time
3
1
2
Press Random Mode
3
Short random from clock mode
OR Long random from countdown mode
RND
L
RND
-
Select Program 20 with Program
Solid for programmable random
* Short random: 1-2 hours
* Programmable random: only works with Program 20
The various modes are arranged in a circular pattern:
Program 1 to 20
The to-the-second countdown feature of this timer starts from the ON or OFF
position and counts down to zero when activated.
Select countdown mode using Program
Repeat steps to to undo disable ( X )
1
Stop countdown timer with Countdown or On/Off
4
Deactivate random function with Random Mode or On/Off
MANUAL ON/OFF
Power On and Off with ON/OFF
LED Indicator
Day/
Sec
Hour
Reset
Minute
S/W
Count-
down
On/Off
Random
Mode
Program
setting the clock
1
From clock mode, go to clock setting
mode by pressing Program once
selecting modes
Clock SettingClock Countdown
Day select with Day/Sec
3
Hour select with Hour
4
Minute select with Minute
5
Toggle between 12 and 24 hour format using Random Mode
6
Press Program
Press S/W while in clock mode to activate/deactivate Daylight Savings
Time (DST); solid for DST
2
Day select with Day/Sec
3
Hour select with Hour
4
Minute select with Minute
5
Press Program
2
For single disable, you must disable both
Program-On and the corresponding Program-Off
Press Program
3
Day/
Sec
Hour
Reset
Minute
S/W
Count-
down
On/Off
Random
Mode
Program
Tip: For quick access to countdown mode, press and hold Day/Sec and
Program together for a quick second then release immediately
3
Hour select with Hour
4
Minute select with Minute
2
Second select with Day/Sec
5
Select On or Off position with On/Off
6
Press Countdown to start countdown timer or press
Program to complete setting
Start countdown timer in any mode by pressing Countdown
activating countdown timer
* Long random: 2-3 hours
RND
Day/
Sec
Hour
Reset
Minute
S/W
Count-
down
On/Off
Random
Mode
Program
2
3
4
5
6
1
Day/
Sec
Hour
Reset
Minute
S/W
Count-
down
On/Off
Random
Mode
Program
3
1 5
2
4
Day/
Sec
Hour
Reset
Minute
S/W
Count-
down
On/Off
Random
Mode
Program
1
2
3
2
1
3
4
6
5
Day/
Sec
Hour
Reset
Minute
S/W
Count-
down
On/Off
Random
Mode
Program
3
1
2
Day/
Sec
Hour
Reset
Minute
S/W
Count-
down
On/Off
Random
Mode
Program
3
1
2
4
http://waterheatertimer.org/UPM-timers-and-manuals.html
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für UPM ET-170 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info