Zoom out
Zoom in
Vorherige Seite
1/48
Nächste Seite
For the owner and heating engineer
VRT 360f
Operating and Installation Manual
VRT 360f
Room temperature thermostat
GB
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Inhalt der Seiten


  • Page 1

    For the owner and heating engineer

    Operating and Installation Manual

    VRT 360f

    Room temperature thermostat
    GB

    VRT 360f



  • Page 2

    Contents

    Inhaltsverzeichnis
    Notes on the documentation . . . . . . 4
    Storage of the documents .................... 4
    Symbols used ........................................... 4
    Safety . . . . . . . . . . . . . . . . . . . . . . . . . 5
    Operating manual. . . . . . . . . . . . . . . . 6
    1

    Overview of the equipment . . . . .

    2

    Overview of the display . . . . . . . 7

    3

    Description of the appliance . . . 8

    4

    Operation. . . . . . . . . . . . . . . . . . . 8

    2

    4.1 Setting the operating modes ...... 9
    4.2 Setting the current day and
    time ................................................... 12
    4.3 Setting timer programmes .......... 13
    4.4 Setting the room temperature ... 16
    4.5 Setting the hot water
    temperature .................................... 18
    4.6 Activating special functions ........ 19
    4.7 Info level ........................................... 22
    4.8 Changing the battery .................... 23

    6

    5

    Manufacturer’s warranty and
    liability . . . . . . . . . . . . . . . . . . . . 25

    6

    Recycling and disposal . . . . . . . . 25

    Operating and installation manual VRT 360f



  • Page 3

    Contents
    Installation instructions . . . . . . . . . . 27
    Notes on the installation and
    operation . . . . . . . . . . . . . . . . . . . 27
    7.1 CE label ............................................. 27
    7.2 Intended use.................................... 28

    10 Electrical installation . . . . . . . . . 35
    10.1 Connecting the receiver ............... 35

    7

    Safety instructions and regulations . . . . . . . . . . . . . . . . . . . . . . . . 29
    8.1 Safety instructions ........................ 29
    8.2 Regulations ...................................... 30

    11
    11.1
    11.2
    11.3

    Start-up . . . . . . . . . . . . . . . . . . . . 36
    Installer level ................................... 37
    Service/diagnostics level .............. 41
    Handing over the appliance to
    the owner ......................................... 43

    12

    Troubleshooting . . . . . . . . . . . . .44

    13

    Technical data . . . . . . . . . . . . . . .45

    14

    Vaillant Service . . . . . . . . . . . . .46

    8

    9
    9.1
    9.2
    9.3

    Installation . . . . . . . . . . . . . . . . . 31
    Place of installation ....................... 31
    Fitting the receiver ........................ 31
    Mounting the room temperature
    thermostat ....................................... 33

    Operating and installation manual VRT 360f

    GB

    3



  • Page 4

    Notes on the documentation

    Notes on the documentation
    The following information is intended to
    help you throughout the entire
    documentation.
    Other documents apply in combination
    with this installation and operation
    manual.
    We accept no liability for any damage
    caused by failure to observe these
    instructions.

    Symbols used
    Please observe the safety instructions in
    this manual for the installation of the
    appliance.
    Danger!
    Immediate risk of serious injury
    or death
    Caution!
    Potentially dangerous situation
    for the product and environment.

    Storage of the documents
    Please pass on this operating and
    installation manual to the owner of the
    system in order for him/her to store it so
    that it is available whenever it is required.
    4

    Operating and installation manual VRT 360f



  • Page 5

    Notes on the documentation, safety
    Note!
    Useful information and
    instructions.
    • Symbol for a necessary task

    Operating and installation manual VRT 360f

    Safety
    The room temperature thermostat must
    be installed by a suitably qualified
    heating engineer, who is responsible for
    adhering to the existing standards and
    regulations.
    We accept no liability for any damage
    caused by failure to observe these
    instructions.

    GB

    5



  • Page 6

    1 Overview of the device

    Operating manual
    1

    Overview of the equipment

    1

    2

    Key
    1 Display
    2 Dial (turn and click)
    I Info button
    F Special functions button
    P Programming key/installer level

    Abb. 1.1 Overview of equipment

    6

    Operating manual VRT 360f



  • Page 7

    Overview of the display 2

    2

    Overview of the display

    11

    1

    10

    2

    9

    3
    4

    8

    5

    7
    6

    Fig. 2.1 Overview of the display

    Operating manual VRT 360f

    Key
    1 Installer level and
    Service/Diagnosis level (Chapter 11.1)
    2 Info level (see 4.7)
    3 Hot water symbol
    4 Circulation pump symbol
    5 Heating circuit symbol
    6 Time/temperature display
    7 Days of the week
    8 Actual temperature
    9 Operating modes (see 4.1)
    10 Special functions (see 4.6)
    11 Setting timer programmes (see 4.3)

    GB

    7



  • Page 8

    3 Device description, 4 Operation

    3

    Description of the
    appliance

    The VRT 360f is a programmable room
    temperature thermostat with weekly
    programme for heating, hot water and
    circulation pump for connection to
    Vaillant heating equipment with eBus.
    The connection between the room
    temperature thermostat and the heating
    unit is by radio link.
    The VRT 360f enables you to specify the
    room temperature using heating
    programs. In addition, you can select
    special functions such as the party
    function, and control the timed

    8

    operation of a boiler and a circulation
    pump.

    4

    Operation

    The operating principle is based on the
    three buttons and an dial (Vaillant "turn
    and click“ operating concept).
    The display normally shows the current
    operating mode (e.g.
    ), or, if
    activated, the special function and the
    current room temperature, the day of
    the week, the time and the symbol for
    heating, hot water and/or the circulation
    pump, depending on which is requested.

    Operating manual VRT 360f



  • Page 9

    Operation 4
    4.1
    Setting the operating modes
    Table 4.1 provides you with an overview
    of the operating modes you can select.
    The selected operating mode affects the
    timer programmes both for heating and
    for hot water and the circulation pump.
    • When the room temperature
    thermostat is in normal display mode.
    press the dial once – the symbol for
    the selected mode flashes in the
    display.
    • Turn the dial until the desired
    operating mode appears on the
    display.
    The display switches back to normal
    mode after five seconds.

    Operating manual VRT 360f

    GB

    9



  • Page 10

    4 Operation
    Symbol

    Meaning
    Heating
    Automatic:
    The operation of the heating circuit changes between
    the operation modes Heating and Energy Saving
    . The heating circuit symbol is displayed if a heating
    requirement is detected.
    Heating:
    The heating circuit is operated according to the
    room temperature, regardless of the programme set
    on the room temperature thermostat. The heating
    circuit symbol is displayed if a heating requirement is
    detected.
    Energy Saving:
    The heating circuit is operated according to the
    energy saving temperature "ECO“, regardless of the
    programme set on the room temperature thermostat.
    The heating circuit symbol is displayed if a heating
    requirement is detected.

    Hot water
    The operation of the hot water
    storage cylinder/circulation
    pump changes between
    heating/ON and OFF
    depending upon the time
    programme set on the room
    temperature thermostat.
    The hot water symbol and the
    circulation pump symbol are
    displayed if the time window
    is active.

    Table 4.1 Operating modes

    10

    Operating manual VRT 360f



  • Page 11

    Operation 4
    Symbol

    Meaning
    Heating
    Off:
    The heating circuit is off, provided that
    the frost protection function (if the room
    temperature is below 5°C)
    is not activated.
    If the frost protection function is activated,
    the heating circuit symbol is displayed.

    Hot water
    The boiler is not heated up, regardless of
    the set timer programme. The circulation
    pump is switched off. The hot water
    and circulation pump symbols are not
    displayed.

    Table 4.1 Operating modes (contd.)

    Operating manual VRT 360f

    GB

    11



  • Page 12

    4 Operation
    4.2

    Setting the current day and
    time
    To set the current time and day of the
    week with the display in normal mode,
    you must perform the following steps:
    • Press the dial until a day of the week
    starts flashing.
    • Turn the dial until you see the current
    day of the week.
    MO = Monday
    TU = Tuesday
    WE = Wednesday
    TH = Thursday
    FR = Friday
    SA = Saturday
    SU = Sunday

    12

    • Press the dial. The hours start flashing.
    • Turn the dial until you see the current
    hour.
    • Press the dial. The minutes start
    flashing.
    • Turn the dial until you see the current
    minute.
    The display switches back to normal
    mode after five seconds.
    If the calendar is activated on the
    installer level (see 11.1), you can set the
    day, month and year in the same way
    after you set the time. This allows
    automatic switching from winter to
    summer time.

    Operating manual VRT 360f



  • Page 13

    Operation 4
    4.3 Setting timer programmes
    The room temperature thermostat is
    equipped with a basic program (see table
    4.2).
    Time
    window

    Current day
    / Block of
    days

    Start
    time

    End
    time

    H1
    H2
    H3
    H1
    H2
    H3
    H1
    H2
    H3

    M0 - FR


    SA


    SU



    6:00


    7:30


    7:30



    22:00


    23:30


    22:00



    Operating manual VRT 360f

    Table 4.2 Default heating, hot water and
    circulation pump programmes

    You can adapt the default programmes
    to suit your needs. There are six steps to
    setting the times you want.
    1. Press the programming button P
    2. Select the timer programme (heating,
    hot water or circulation pump)
    3. Select the time window
    4. Select the current day or week block
    5. Set the start time.
    6. Set the end time.

    GB

    13



  • Page 14

    4 Operation
    You can define three time windows for
    each day.
    When you press the P button the display
    returns to basic mode.
    The table below illustrates the individual
    steps again, using the example of the hot
    water timer programme. If you want to
    change the timer programme for heating
    or the circulation pump, after pressing
    the programming button P, select the
    corresponding symbol (heating circuit or
    circulation pump) and continue as shown
    in the example.

    14

    Display

    Required steps
    Press the programming
    button P. The cursor (black
    triangle) marks the value
    which can be changed ( ),
    which also flashes.
    Turn the dial until the tap
    symbol appears.
    Press the dial. The cursor
    marks the adjustable value
    (H1), which also flashes.
    Select the desired time
    window by turning the dial.
    Settings: H1, H2, H3

    Operating manual VRT 360f



  • Page 15

    Operation 4
    Display

    Required steps
    Press the dial. The cursor
    marks the week block
    display, which also flashes.
    Select a block programme
    or a single day of the week
    by turning the dial.
    Settings:
    MO - SU
    MO - FR
    SA - SU
    MO = Monday
    TU = Tuesday
    WE = Wednesday
    TH = Thursday
    FR = Friday
    SA = Saturday
    SU = Sunday

    Operating manual VRT 360f

    Display

    Required steps
    Press the dial. The cursor
    marks the start time and the
    hour display flashes.
    Select the start time by
    turning the dial. Press
    the dial again to set the
    minutes.
    Press the dial. The cursor
    marks the end time and the
    hour display flashes.
    Select the end time by
    turning the dial. Press
    the dial again to set the
    minutes.

    Table 4.3 Setting time windows

    GB

    15



  • Page 16

    4 Operation
    If necessary, you can switch the room
    temperature thermostat from the week
    programme to a daily programme.
    • With the display in normal mode, press
    the F button for about 10
    seconds. When you programme time
    windows, days of the week will no
    longer be displayed.
    4.4 Setting the room temperature
    The current room temperature is shown
    in the basic display.
    You can set the room temperature
    directly from the basic display.
    If the temperature level function is
    activated on the installer level (different
    temperature settings for each heating
    16

    window see Chapter 11.1), the display
    shows the currently set room
    temperature (T-H1, T-H2, T-H3).
    Setting the required room temperature
    directly
    • Turn the dial (with the display in
    normal mode).
    The set temperature display
    disappears, the sun symbol is
    displayed in the operating mode level
    and the set room temperature is
    displayed in the multi-function level
    (e.g. TEMP 20,0 °C).

    Operating manual VRT 360f



  • Page 17

    Operation 4
    • You can set the required room
    temperature directly (after about 1
    second) to the desired value by turning
    the dial.
    The display switches back to normal
    mode after five seconds.




    Setting the room temperature for time
    windows
    (only possible if the "Temperature level"
    function is activated on the installer
    level - see 11.1). In this case, you can set
    different room temperatures for each
    time window.





    along with a set value. The set value
    flashes.
    Turn the dial until you see the room
    temperature you want for the time
    window H1. The new room temperature
    is assigned to all time windows with H1.
    Press the dial. T-H2 is displayed along
    with a set value. The set value flashes.
    Turn the dial until you see the room
    temperature you want for the time
    window H2. The new room
    temperature is assigned to all time
    windows with H2.
    Press the dial. T-H3 is displayed along
    with a set value. The set value flashes.

    • Press the dial several times until T-H1
    appears in the multifunction display
    Operating manual VRT 360f

    GB

    17



  • Page 18

    4 Operation
    • Turn the dial until you see the room
    temperature you want for the time
    window H3. The new room
    temperature is assigned to all time
    windows with H3.
    The display switches back to normal
    mode after five seconds.
    Setting the set-back temperature
    "ECO“
    • Push the dial until ECO appears.
    The set-back temperature is displayed
    and starts flashing.
    • Turn the dial until the required setback temperature is displayed (e.g.
    ECO 15 °C).

    18

    The display switches back to normal
    mode after five seconds.
    4.5

    Setting the hot water
    temperature
    You can set the hot water temperature
    from the basic display. Please note the
    set maximum hot water temperature on
    the boiler.
    • Push the dial repeatedly until the DHW
    display appears. The set value flashes.
    • Turn the dial until the required hot
    water temperature is displayed (e.g.
    DHW 60 °C).
    The display switches back to normal
    mode after five seconds.

    Operating manual VRT 360f



  • Page 19

    Operation 4
    4.6 Activating special functions
    You can access the special functions
    using the F button. You can activate the
    following functions:

    Operating manual VRT 360f

    Display

    Required steps
    Quick veto
    The quick veto function
    allows you to adjust the room
    temperature for a short time
    (until the next time window).
    Press the special function
    button F - the quick veto
    symbol appears in the display
    along with the quick veto room
    temperature, which also flashes.
    Turn the dial until the quick
    veto temperature you want is
    displayed. The display switches
    back to basic mode after 10
    seconds and the function is
    activated. To deactivate the
    function, all you need to do is
    press the F button.

    GB

    19



  • Page 20

    4 Operation
    Display

    Required steps
    Energy-saving function
    The energy-saving function lets
    you lower the heating for an
    adjustable period regardless
    of the set heating programme.
    Press the special function
    button twice and the energysaving symbol appears on the
    display. You will also see the
    time flashing. Now turn the dial
    to set the end time up to which
    the heating is operated in setback mode. The display switches
    back to basic mode after 10
    seconds and the function is
    activated. To deactivate the
    function, all you need to do is
    press the F button.

    20

    Display

    Required steps
    Party function
    When you activate the party
    function the heating phase is
    continued beyond the next setback phase. This also applies to
    the hot water and circulation
    pump programmes. Press the
    special function button three
    times. The party symbol appears
    in the display and the function is
    activated after ten seconds.
    The function is deactivated
    automatically by reaching the
    next heating phase.
    If you want to deactivate the
    function before, just press the F
    button. This function can only be
    activated in automatic mode .

    Operating manual VRT 360f



  • Page 21

    Operation 4
    Display

    Operating manual VRT 360f

    Required steps

    Display

    Required steps

    Once-only cylinder filling

    Holiday function

    The once-only cylinder filling
    function allows you to fill the
    cylinder, regardless of the set
    timer programme. Press the
    special function button four
    times. The once-only cylinder
    filling symbol appears in the
    display and the function is
    activated after ten seconds.
    If you want to deactivate the
    function early, just press the F
    button.

    The holiday function deactivates
    the controller, but not the frost
    protection function. The hot
    water and circulation pump are
    also deactivated. Push the special
    function button five times - the
    holiday function appears in the
    display along with set value of the
    number of days' holiday, which
    then flashes.
    Turn the dial until the required
    number of day's holiday appears.
    After 10 seconds the function is
    activated and the mode is set to
    OFF for the selected period
    ¬
    (see Chapter 4.1).

    GB

    21



  • Page 22

    4 Operation
    Display

    Required steps
    ¬ Holiday function
    If you want to deactivate the
    function before, just press the F
    button. If the anti-legionnaire's
    disease function is activated, it is
    performed on the last day of the
    holiday.

    Table 4.4 Special functions

    4.7 Info level
    Press the info button to access the info
    level. The info symbol appears in the
    display as soon as you open the info
    level. Each time you press the button,
    different information is displayed:

    22

    - The name of the room temperature
    thermostat (VRT 360f )
    - The quick veto room temperature (if
    active)
    - The set room temperature T-H1 (if
    activated - e.g. T-H1 20.0 °C)
    - The set room temperature T-H2 (if
    activated - e.g. T-H2 23.0 °C)
    - The set room temperature T-H3 (if
    activated - e.g. T-H3 18.0 °C)
    - The required room temperature if the
    temperature level function is not
    activated (e.g. TEMP 20.0 °C)
    - The set set-back temperature
    (e.g. ECO 15.0 °C)
    - The set hot water temperature
    (e.g. DHW 60 °C)
    Operating manual VRT 360f



  • Page 23

    Operation 4
    - The day/month/year (if the calendar is
    activated)
    - The timer programmes set for heating
    (every single time window per day)
    - The timer programmes set for hot
    water (every single time window per
    day)
    - The timer programmes set for the
    circulation pump (every single time
    window per day)

    Approx. 4 weeks before the battery is
    fully discharged BATT appears in the
    multifunction display of the basic display.
    The battery chamber is located on the
    back of the regulator. The regulator must
    be taken off the wall plinth to change the
    battery.
    • Carefully push the retaining hook to
    the side using a screwdriver (Fig. 4.1)
    and pull the regulator away to the
    front.

    4.8 Changing the battery
    The regulator checks the battery
    condition itself, and the normal working
    life of the battery is approx. 1.5 years.

    Operating manual VRT 360f

    GB

    23



  • Page 24

    4 Operation

    Fig. 4.2 Changing the batteries
    Fig. 4.1 Releasing the locking hook

    • The batteries can now be changed
    (2x AAA-LR03; Fig. 4.2). Make sure
    that the polarity of the batteries is
    correct.

    24

    If the batteries are not changed in time,
    the regulator switches over to operating
    , to prevent the
    mode "Heating"
    installation from freezing up.

    Operating manual VRT 360f



  • Page 25

    Works guarantee and liability 5, Recycling and disposal 6

    5

    Manufacturer’s warranty
    and liability

    Vaillant warranty
    We only grant a Vaillant manufacturers
    warranty if a suitably qualified engineer
    has installed the system in accordance
    with Vaillant instructions. The system
    owner will be granted a warranty in
    accordance with the Vaillant terms and
    conditions. All requests for
    work during the guarantee period must
    be made to Vaillant Service Solutions
    (0870 6060 777).

    Operating manual VRT 360f

    6

    Recycling and disposal

    Both your Valliant room temperature
    thermostat VRT 360f and its packaging
    consist mainly of recyclable raw
    materials.
    Appliance
    Do not dispose of your Valliant room
    temperature thermostat VRT 360f or
    any of its accessories with the household
    waste. Make sure the old appliance and
    any accessories are disposed of properly.

    GB

    25



  • Page 26

    6 Recycling and disposal
    Packaging
    Please leave the disposal of the
    transport packaging to the qualified
    servicing company which installed the
    appliance.

    26

    Operating manual VRT 360f



  • Page 27

    Information on the installation and operation 7

    Installation instructions
    7

    Notes on the installation
    and operation

    The assembly, electrical connection and
    the settings in the device as well as the
    commissioning must be carried out only
    by a suitably qualified heating engineer.
    Check the site of installation before
    fitting the unit with regard to possible
    radio interference by electrical
    equipment or building influences which
    may affect the functioning.

    Installation instructions VRT 360f

    If the radio signal route is compromised
    then an alternative installation site must
    be chosen.
    7.1
    CE label
    The CE label shows that the VRT 360f
    room temperature thermostat, when
    connected to Vaillant boilers, meets the
    basic requirements of the Council of
    Europe's directive 89/336/EEC on
    electromagnetic compatibility and the
    low voltage directive 73/23/EEC.

    GB

    27



  • Page 28

    7 Information on the installation and operation
    7.2
    Intended use
    The Valliant room temperature
    thermostats VRT 360f are state-of-theart appliances which are designed in
    accordance with approved safety
    regulations. Nevertheless, there is still a
    risk of injury or death to the user or
    others or of damage to the device and
    other property in the event of im-proper
    use or use for which it is not intended.
    The VRT 360f room temperature
    thermostat is designed to control a
    heating system with or without a hot
    water system or circulation pump
    according to time and location, in
    connection with a Vaillant boiler with an
    eBus interface.
    28

    The connection between the room
    temperature thermostat and the heating
    unit is by radio.
    Any other use or extended use is
    considered to be improper. The
    manufacturer or supplier is not liable for
    any resulting damage. The user alone
    bears the risk.
    Use includes observance of the
    operating and installation manuals and
    all other applicable documents, as well
    as adherence to the maintenance and
    inspection conditions.
    Caution!
    Any improper use is forbidden.

    Installation instructions VRT 360f



  • Page 29

    Safety instructions and regulations 8

    8

    Safety instructions and
    regulations

    The unit must be installed by a suitably
    qualified heating engineer, who is
    responsible for adhering to the existing
    standards and regulations. We accept no
    liability for any damage caused by failure
    to observe these instructions.

    Installation instructions VRT 360f

    8.1

    Safety instructions
    Danger!
    Risk of fatal electric shock from
    touching live connections.
    Before working on the appliance,
    turn off the power supply and
    secure against restart.
    Only remove the room
    temperature thermostat from
    the wall mounting or from the
    plinth when it is potential free.

    GB

    29



  • Page 30

    8 Safety instructions and regulations
    8.2 Regulations
    Use standard commercial cables for
    wiring.
    - Minimum cross-section of the wires:
    0.75 mm2
    Do not exceed following maximum wire
    lengths:
    - Bus lines: 300 m
    Connection lines at 230 V and bus wires
    must be laid separately when longer
    than 10 m.
    The room temperature thermostat may
    only be installed in dry rooms.

    30

    All wiring must be in accordance with
    Building Regulations Part P and BS 7671
    (IEE Wiring Regulations), and must be
    carried out by a suitably qualified person.

    Installation instructions VRT 360f



  • Page 31

    Installation 9

    9

    Installation

    9.1
    Place of installation
    The room temperature thermostat must
    be installed to ensure that it can
    properly record the room temperature
    (away from heat traps, not mounted on
    cold walls etc.).
    The best place for installation is usually
    in the main living room on an inside wall
    at approx. 1.5 m height. There, the room
    temperature thermostat should able to
    record the circulating air, unhindered by
    furniture, curtains or other objects.

    Installation instructions VRT 360f

    Choose a location where the room
    temperature thermostat is not affected
    by draughts from doors or windows, or
    by heat sources such as radiators,
    chimney walls, televisions and direct
    sunlight. All the radiator valves in the
    room where the thermostat is installed
    must be fully open.
    9.2 Fitting the receiver
    The connection of the receiver to the
    boiler is via a 2-core bus cable (eBus).

    GB

    31



  • Page 32

    9 Installation

    Fig. 9.1 Connection to one boiler

    Install the receiver outside the heating
    unit using the plinth supplied (Fig. 9.1)

    32

    • Pull the receiver (1) off the wall plinth
    (2).
    • Drill two holes (3) of 6 mm diameter
    (as shown in fig. 9.2) and put in the
    supplied wall plugs.
    • Push the connection cable (4) through
    the cable ducting (5).
    • Attach the wall plinth to the wall with
    the two screws provided.
    • Connect the cable as described in
    Chapter 10.
    • Place the receiver (1) on the wall plinth
    so that the pins on the back of the
    upper section fit into the receptacles.
    • Push the receiver onto the wall plinth
    until it clicks.

    Installation instructions VRT 360f



  • Page 33

    Installation 9
    9.3
    1

    2

    4
    5

    Fig. 9.2 Mounting the receiver

    Installation instructions VRT 360f

    3

    1
    2

    Mounting the room temperature
    thermostat
    Check the site of installation before
    fitting the unit with regard to possible
    radio interference by electrical
    equipment or building influences which
    may affect the functioning. If the radio
    signal route is compromised then an
    alternative installation site must be
    chosen.
    • Pull the room temperature thermostat
    (1) off the wall plinth (3).
    • Drill two holes (2) of 6 mm diameter
    (as shown in fig. 9.3) and put in the
    supplied wall plugs.
    • Attach the wall plinth to the wall with
    the two screws provided.
    GB

    33



  • Page 34

    9 Installation
    • Insert the batteries supplied into the
    battery compartment at the back of
    the regulator (Fig. 9.3, Item 4). Make
    sure that the polarity of the batteries
    is correct. Connect the connection
    cable as per Chapter 10.
    • Push the room temperature
    thermostat onto the wall plinth until it
    clicks.

    1

    2
    3

    4

    Fig. 9.3 Mounting the room temperature
    thermostat

    34

    Installation instructions VRT 360f



  • Page 35

    Electrical installation 10

    10 Electrical installation
    The electrical connection may only be
    carried out by a suitably qualified
    heating engineer.
    Danger!
    Risk of fatal electric shock from
    touching live connections. Before
    carrying out work on the
    controller, switch off the power
    supply and secure it against
    being switched on again.

    Installation instructions VRT 360f

    10.1 Connecting the receiver
    Communication to the boiler takes place
    using a 2-core bus cable (eBus). All eBus
    connector plugs are designed to allow at
    least 2 x 0.75 mm2 (recommended) per
    connection terminal. This means that the
    wires can be swapped without impairing
    communication (fig. 10.1). Also follow the
    instructions for the boiler. Do not
    remove the jumper between terminals 3
    and 4 on the boiler.

    GB

    35



  • Page 36

    10 Electrical installation, 11 Start-up

    11

    Receptor VRT 360f

    Start-up

    Certain system parameters have to be
    set in order for them to comply with the
    prevailing conditions. These system
    parameters are all together on one
    operating level and should only be set by
    the heating engineer.
    The service/diagnostics level is also
    intended for the engineer and is
    designed to help during servicing.

    Boiler
    Fig. 10.1 Electrical connection

    36

    Installation instructions VRT 360f



  • Page 37

    Start-up 11
    The receiver is equipped with two status
    LEDs. In order to see these you must
    remove the cover of the receiver
    housing. The LEDs provide the following
    information for the system:
    LED

    Condition Function

    green

    on

    Operation OK

    red

    off
    off

    Operation fault
    Operation OK

    on

    Radio signal/eBus error

    flashing

    Reception of a radio signal

    11.1
    Installer level
    Press the P button to access the installer
    level.
    • Push the button P for approx. 10
    seconds
    The spanner symbol and the first
    parameter appear in the display.
    • Press the dial. You can select all the
    system parameters in turn.
    Turn the dial to set the values you want.
    When you press the P button the display
    returns to basic mode.
    You can select and change the following
    parameters:

    Table 11.1 Displays

    Installation instructions VRT 360f

    GB

    37



  • Page 38

    11 Start-up
    Display

    Set by turning the dial
    Set-back temperature
    Factory setting: 15 °C
    Setting range: 5 ... 30° C

    Set hot water temperature
    Factory setting: 60 °C
    Setting range 35 ... 70 °C

    Correction of current room
    temperature
    Adjustment of the displayed
    value by up to max.
    +/- 3 °C
    Factory setting: 0 °C

    38

    Display

    Set by turning the dial
    Anti-legionella function
    1 = Activate the antilegionnaire's disease
    programme.
    Every Wednesday, one hour
    before the first time window,
    a connected hot water
    cylinder is heated to 70 °C,
    and the circulation pump is
    switched on and operated
    at 70 °C for at least 30
    minutes.
    Factory setting: 0 (off)

    Installation instructions VRT 360f



  • Page 39

    Start-up 11
    Display

    Set by turning the dial
    Two-point/analogue
    operation
    2-point/analogue mode
    change-over.
    The room temperature
    thermostat is set in the
    factory as a 2-point
    regulation system (set
    value 0). You can set it to
    analogue mode by changing
    the parameter to 1.

    Installation instructions VRT 360f

    Display

    Set by turning the dial
    Control characteristics/
    route adjustment
    For optimum adaptation to
    the room size or radiator
    configuration
    Factory setting: 0
    Setting range: -5 ... +5
    (Positive values: slow
    reaction speed of the room
    temperature thermostat;
    negative values:
    faster reaction speed of
    the room temperature
    thermostat)

    GB

    39



  • Page 40

    11 Start-up
    Display

    Set by turning the dial
    Day setting
    For activation of the
    calendar

    Month setting
    For activation of the
    calendar

    Display

    Set by turning the dial
    Temperature level
    Activate the setting for
    different temperatures for
    each time window.
    0 = Temperature level off
    1 = Temperature level on
    Factory setting: 0
    Temperature level time
    window H1
    (only when temperature
    levels are activated)

    Year setting
    For activation of the
    calendar

    40

    Installation instructions VRT 360f



  • Page 41

    Start-up 11
    Display

    Set by turning the dial
    Temperature level time
    window H2
    (only when temperature
    levels are activated)
    Temperature level time
    window H3
    (only when temperature
    levels are activated)

    Table 11.2 System parameters

    11.2 Service/diagnostics level
    Access the service/diagnostics level by
    pressing the P button and the dial.
    • Press the P button and the dial
    simultaneously for approx. 3 seconds.
    First, a heating request for 50 °C is
    triggered to test communication with the
    boiler.
    Then you can select all the test options
    by pressing or turning the dial
    (see table 11.3).
    When you press the P button the display
    returns to basic mode.
    You can select the following tests:

    Installation instructions VRT 360f

    GB

    41



  • Page 42

    11 Start-up
    Dial
    Test
    Press and Heating
    request
    push P
    button for
    approx. 3
    seconds.

    Test procedure
    A heating request of
    50°C is simulated.
    The burner on the
    boiler starts up and
    the pump starts (only
    up to the maximum
    supply temperature of
    the boiler).

    Turn

    The circulation pump
    is activated. All other
    elements are switched
    off.

    Circulation
    pump

    Dial
    Press

    Test
    Test procedure
    Radio route The radio route
    is tested. Radio
    signals are sent to
    the receiver every 5
    seconds (max. 99).
    The number of
    correctly received
    radio signals is
    displayed.

    Press

    Display test All display elements
    are displayed.

    Press

    Software
    version

    The software version
    is displayed.

    Table 11.3 Service/diagnostic level

    42

    Installation instructions VRT 360f



  • Page 43

    Start-up 11
    Restoring the default settings
    • To return the room temperature
    thermostat to its default settings,
    press the P button for 15 seconds. As
    soon as the display lights up twice, the
    room temperature thermostat has
    been reset. This means that you will
    have to perform all individual settings
    again.

    Installation instructions VRT 360f

    11.3

    Handing over the appliance to
    the owner
    The owner of the room temperature
    thermostat must be instructed about its
    functions and how to operate it.
    • Hand over the manuals intended for
    the owner as well as the documents of
    the appliance.
    • Go through the operating manual with
    him and answer his questions.
    • Draw special attention to the safety
    instructions which the owner must
    follow.
    • Tell the owner to keep the manuals
    nearby the controller.

    GB

    43



  • Page 44

    12 Troubleshooting

    12 Troubleshooting
    The room temperature thermostat signals the following fault conditions:
    Fault signal

    Meaning

    Troubleshooting

    RF Err

    No radio connection to the radio
    receiver on the heating unit

    Check the site of installation.

    BATT

    low battery condition, replacement
    required

    Replace the batteries.

    BMU Err

    Fault on heating unit.

    Call the installer.

    MAIN

    Heating unit maintenance required

    Call the installer.

    Table 12.1 Fault signals

    44

    Installation instructions VRT 360f



  • Page 45

    Technical data 13

    13

    Technical data

    Description
    Operating voltage
    Maximum permissible ambient temperature
    Battery working life
    Transmission frequency
    Transmission capacity
    Current consumption
    Minimum cross-section of the connection lines
    Level of protection
    Protection rating for regulator
    Dimensions
    Height/width/depth

    Unit
    V
    °C
    Months
    MHz
    mW
    mA
    mm2

    mm

    Sender
    3V (2xAAA)
    50
    approx. 18
    868,35
    0,5
    ≤ 0,4 (readiness)
    0,75
    IP 20
    III

    Receiver
    24
    50

    IP 20
    III

    97/146/27

    97/146/27

    868,35
    ≤ 12 (readiness)

    Table 13.1 Technical data

    Installation instructions VRT 360f

    GB

    45



  • Page 46

    14 Vaillant Service

    14 Vaillant Service
    Vaillant Service
    To ensure regular servicing, it is strongly
    recommended that arrangements are
    made for a Maintenance Agreement.
    Please contact Vaillant Service Solutions
    (0870 6060 777) for further details.

    46

    Installation instructions VRT 360f



  • Page 47



  • Page 48

    Kent ME2 4EZ
    info@vaillant.co.uk

    838571_00 GB 07 2006

    Vaillant Ltd
    Vaillant House
    Medway City Estate
    Trident Close
    Rochester
    Telephone 01634 292300
    Fax 01634 290166
    www.vaillant.co.uk






Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Vaillant VRT 360F wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Holen Sie sich Ihr Benutzerhandbuch per E-Mail

Geben Sie Ihre E-Mail-Adresse ein, um das Handbuch zu erhalten von Vaillant VRT 360F in der Sprache / Sprachen: Englisch als Anhang in Ihrer E-Mail.

Das Handbuch ist 0,3 mb groß.

 

Sie erhalten das Handbuch in Ihrer E-Mail innerhalb von Minuten. Wenn Sie keine E-Mail erhalten haben, haben Sie wahrscheinlich die falsche E-Mail-Adresse eingegeben oder Ihre Mailbox ist zu voll. Darüber hinaus kann es sein, dass Ihr ISP eine maximale Größe für E-Mails empfangen kann.

Andere Handbücher von Vaillant VRT 360F

Vaillant VRT 360F Bedienungsanleitung - Deutsch - 104 seiten

Vaillant VRT 360F Bedienungsanleitung - Holländisch - 54 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info