5. Press ALARM to enable/disable the alarm. If the alarm is enabled, the corresponding alarm indicator and
HI AL (or LO AL for a low alarm) appear on the display.
6. Press SET to confirm the current setting and go to the next.
7. To return to normal mode, press HISTORY.
High alarm settings
High alarm
Description
Time alarm
Set the time (hours:minutes) when you want the alarm to go off.
Note: you can also set the time alarm via low alarms settings.
Wind speed
Set the wind speed threshold value (0~50m/s). The alarm goes off when the wind speed
is higher than the specified value.
Gust speed
Set the gust speed threshold value (0~50m/s). The alarm goes off when the gust speed
is higher than the specified value.
Wind direction
Set the wind direction. The alarm goes off when the wind comes from the specified
direction.
1 hour rainfall
Set the value of rainfall in 1 hour (0~999.9mm). The alarm goes off when there is more
rain in 1 hour than the specified value.
24 hour rainfall
Set the value of rainfall in 24 hours (0~999.9mm). The alarm goes off when there is
more rain in 24 hours than the specified value.
Outdoor humidity
Set the outdoor humidity value (1%~99%). The alarm goes off when the outdoor
humidity is higher than the specified value.
Outdoor
temperature
Set the outdoor temperature value (-40°C~+60°C). The alarm goes off when the
outdoor temperature is higher than the specified value.
Wind chill
Set the wind chill value (-40°C~+60°C). The alarm goes off when the wind chill
temperature is higher than the specified value.
Dew point
Set the dew point value (-40°C~+60°C). The alarm goes off when the dew point
temperature is higher than the specified value.
Indoor humidity
Set the indoor humidity value (1%~99%). The alarm goes off when the indoor humidity
is higher than the specified value.
Indoor temperature
Set the indoor temperature value (-9.9°C~+60°C). The alarm goes off when the indoor
temperature is higher than the specified value.
Low alarm settings
Low alarm
Description
Outdoor humidity
Set the outdoor humidity value (1%~99%). The alarm goes off when the outdoor
humidity is lower than the specified value.
Outdoor
temperature
Set the outdoor temperature value (-40°C~+60°C). The alarm goes off when the
outdoor temperature is lower than the specified value.
Wind chill
Set the wind chill value (-40°C~+60°C). The alarm goes off when the wind chill
temperature is lower than the specified value.
Dew point
Set the dew point value (-40°C~+60°C). The alarm goes off when the dew point
temperature is lower than the specified value.
Indoor humidity
Set the indoor humidity value (1%~99%). The alarm goes off when the indoor humidity
is lower than the specified value.
Indoor temperature
Set the indoor temperature value (-9.9C~+60°C). The alarm goes off when the indoor
temperature is lower than the specified value.
7.5 Minimum and maximum
The weather station keeps track of minimum and maximum measurements for each weather condition (since
the last reset), together with the time and date when they were recorded.
Displaying minimum and maximum measurements
To display minimum and maximum measurements, proceed as follows:
1. From normal mode, press MIN/MAX.
The station is now in maximum mode. The displays shows the maximum indicator [6].
2. Press + repeatedly to display the maximum values for: wind speed, gust speed, 1 hour rainfall, 24 hour
rainfall, weekly rainfall, monthly rainfall, outdoor humidity, outdoor temperature, wind chill temperature,
dew point, indoor humidity, indoor temperature.
3. Press MIN/MAX to go to minimum mode. The displays shows the minimum indicator [8].
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Velleman WS1060 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info