OPERATING INSTRUCTIONS
1. Check that the Water Tank (3) is filled and that the Cartridge
(6) is in place.
2. Check that the Power Switch (12) is in the Off-position. Plug
the supply cord into the outlet.
Do not touch the supply
cord with wet hands.
3. Turn the Power Switch (12) to the desired position. The Pilot
Light (13) illuminates. Turn the Power Switch (12) clockwise
to increase mist output; turn it counterclockwise to decrease
mist output.
4. Direct the Mist Nozzle (1) away from people, objects or walls.
5. If surplus humidity condenses on furniture, walls or floors in
closed or small rooms, turn the Power Switch (12) counter-
clockwise to decrease mist output and open the door to
the room. If this does not solve the problem turn the Power
Switch (12) to the Off-position and unplug the humidifier.
6. Before removing the humidifier or filling the Water Tank (3)
turn the Power Switch (12) to the Off-position and unplug the
humidifier.
CLEANING, CARE AND STORAGE
We recommend cleaning the humidifier frequently. In
order to not impair the performance of the humidifier,
follow the instructions for Cleaning, Care and Storage.
Daily Cleaning
1. Before cleaning, turn the Power Switch (12) to the Off-
position and unplug the unit.
2. Remove the Directional Mist Nozzle (1) from the Water Tank
(3) and remove the Water Tank (3) from the Base (11).
3. Remove the Cartridge (6) from the Base (11). Do not wash
or clean the Cartridge (6).
Do not attempt to remove or
in any other way modify the Water Sensor (9). Even
touching it can damage this delicate Sensor.
4. Empty excess water from the Reservoir (7) where indicated by
the arrow and make sure that water does not enter into the Air
Outlet (8) or the Scent Pad Slot (15)
5. Open the Tank Cap (4) by turning it
counter-clockwise and
drain any water from the Water Tank (3).
6. Rinse the Water Tank (3) thoroughly with lukewarm water.
7. Wipe the outer surfaces of the Water Tank (3) with a clean,
damp cloth.
8. To operate the humidifier follow the instructions under
“Filling the Water Tank and “Operating Instructions.
Weekly Cleaning
1. Before cleaning, turn the Power Switch (12) to the Off-
position and unplug the unit.
2. Remove the Directional Mist Nozzle (1) from the Water Tank
(3) and remove the Water Tank (3) from the Base (11).
3. Remove the Cartridge (6) from the Base (11). Do not wash
or clean the Cartridge (6).
Do not attempt to remove or
in any other way modify the Water Sensor (9). Even
touching it can damage this delicate Sensor.
4. Empty excess water from the Base (11) only on side opposite
to the Water Sensor (9) and make sure, that water does not
enter into the Air Outlet (8).
5. Open the Tank Cap (4) by turning it
counter-clockwise and
drain any water from the Water Tank (3).
6. Clean the Water Tank (3) with a solution of bleach and water
(one teaspoon of bleach to one gallon of water). Fill tank
partially with this solution, let stand twenty (20) minutes,
shaking vigorously every few minutes, drain, and rinse with
clean water until the bleach smell is gone.
7. Wipe the Reservoir (7) with a soft cloth dampened in
this solution. If mineral deposits are evident around the
Nebulizer and Water Sensor, clean their surfaces with a
soft, clean cloth and a small amount of undiluted vinegar. If
necessary for removal of mineral deposits, mix a solution of
50% white vinegar and 50% water and fill the Reservoir with
enough solution to cover the Nebulizer. Allow it to soak for an
hour, then use a cotton swab to gently loosen buildup on the
Nebulizer. Rinse out the Reservoir and wipe clean.
Do not
touch Nebulizer or the Water Sensor with bare fingers
as any fingerprints or residue can reduce mist output.
Do not
immerse the Base (11) in water.
8. To operate the humidifier follow the instructions under
“Filling the Water Tank and “Operating Instructions.
Care and Storage
1. Follow the “Weekly Cleaning” instructions when the
humidifier is not used for a longer period (one week or more).
2. Let the humidifier and all its parts dry completely.
3. Remove the Cartridge (6) from the Base (11) and discard.
4. Do
not store the humidifier with a filled Water Tank (3) nor
with a used Cartridge (6).
5. Store the humidifier in a cool, dry place.
ENGLISH
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Vicks V-5200S wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info