RECTAL USE
Commonly used for babies, young children, or when it is difficult to take an oral or underarm temperature.
1. Cover the thermometer’s tip with a probe cover and lubricate with a water-soluble jelly for easier insertion. Do
not use a petroleum jelly. Read the label of the lubricant to be sure you are using the right kind.
2. Lay the patient on his/her side. If the patient is an infant, the proper position for a baby is to lay on its stomach
with legs hanging down, either across your knees or at the edge of a bed or changing table. This positions the
infant’s rectum for safe and easy insertion of the thermometer.
3. Gently insert the tip of the thermometer NO MORE THAN 1/2 inch into the rectum. If you detect resistance, stop.
Hold the thermometer in place during measurement.
4. When the peak temperature is reached (usually 30 seconds) 10 beep signals will sound and the “°F” sign will
stop flashing. The temperature is now ready to read and will not change when the thermometer is removed.
Note: This method produces a temperature 1° higher than a temperature taken orally.
5. Turn the thermometer off by pressing the On/Off button. If you forget to turn it off, the thermometer will
automatically turn off after approximately 10 minutes.
6. Dispose of used probe cover and wash the thermometer as recommended.
TO RECALL THE LAST TEMPERATURE
When the thermometer is turned on, continue to hold the button down approximately 2 seconds. The last measured
temperature will be shown in the LCD display with the letter “M” shown under the degree sign for approximately 3
seconds.
CLEANING INSTRUCTIONS
Clean the thermometer by washing with soap and warm water or rubbing alcohol (70% isopropyl alcohol).
Wipe dry with soft cloth.
DO NOT BOIL OR CLEAN IN DISHWASHER. This will cause the thermometer to no longer function
and will void the warranty.
Do not wash the unit with any thinner or chemical solvent.
CHANGING THE BATTERIES
The VICKS
®
Digital Thermometer features a long life, mercury free battery. When the “
appears in the lower right
of the display, the battery is exhausted and needs replacing.
1. Slide the battery cap away from the unit and carefully remove the battery with a non-metallic pointed instrument.
2. Replace the battery with a 1.55V, L41 alkaline or SR41 silver oxide type or equivalent. Insert the new battery
with the positive (+) side facing the display side of the unit.
3. Carefully slide the battery cap back into place, making sure that the cap is secure to protect the battery
compartment from moisture.
4. Properly discard the old battery. Keep out of reach of young children, elderly and pets.
SPECIFICATIONS
Battery Life: more than 200 hours of continuous operation.
Accuracy in waterbath: +/-0.2°F between 96.0-107.0°F at room temperature of 71°F.
Temperature Range: 90.0° - 108.0°F. If less than 90.0°F an “L” is displayed. If more than 108.0°F an “H” is
displayed.
Beeper: Unit will beep for approximately 8 seconds when peak temperature is reached.
LIFETIME WARRANTY
Your VICKS
®
Digital Thermometer is durable and manufactured for a lifetime of normal, household use. Following
directions carefully will ensure years of dependable operation. If for any reason (other than misuse or normal
battery replacement) you are dissatisfied with your VICKS
®
Digital Thermometer, we will repair or replace it, at our
option, free during your lifetime.
If the thermometer does not function properly, first check the battery. Replace if necessary. If repair is necessary
call our Consumer Relations Department at 1-800-477-0457 or write to Kaz, Inc., Consumer Relations Department,
250 Turnpike Rd., Southborough, MA 01772, explaining just how the thermometer is improperly working. Our
consumer service representative will provide further instruction on how to correct the trouble yourself or will ask
you to return the thermometer for repair or replacement.
k Manufacturing Quality Healthcare Products for Over 75 Years
Kaz, Incorporated • Hudson, NY 12534 • www.kaz.com
Distributed by Kaz, Incorporated under license from The Procter & Gamble Company, Cincinnati, Ohio USA.
Vicks is a registered trademark of The Procter & Gamble Company.
© 2005 KAZ, Incorporated
Made and printed in China
P/N: 31IM900G190
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Vicks V900G wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info