650801
2
Zoom out
Zoom in
Vorherige Seite
1/2
Nächste Seite
shuts off, empty the residue in the medicine cup and clean with a soft tissue. Add fresh inhalant after
refilling water container.
PLUG IN VAPORIZER. IMPORTANT: Vapourizer will NOT START unless vapourizer has been
disconnected for at least one minute. Nightlight will illuminate when electricity is connected. This
will indicate that the heating unit is functioning.
Vapourizer will produce a gentle flow of steam within a few minutes. Do not lift or move the
vapourizer while in use.
OPERATION: Vapourizer will shut off automatically when the water reaches a minimum level (about
20 mm from bottom of container).
VENTILATE ROOM REGULARLY: When vapourizer is used in closed or small rooms, check periodically
for proper ventilation, as excessive humidity can cause condensation on walls.
AFTER EACH USE: Empty any unused water from the container. Rinse container thoroughly, drain
and wipe with a dry, clean cloth. To maintain proper operation of your vapourizer, be sure to follow
CARE AND CLEANING instructions.
Care and Cleaning
IMPORTANT SAFETY CAUTIONS: Always disconnect the plug from the electrical outlet before cleaning.
Remove heating unit, letting all water drain back into the container. Do not attempt to disassemble the
heating unit. Doing so could damage the vapourizer or cause personal injury, and will void the warranty.
Daily Maintenance
Empty any unused water from container. Rinse container thoroughly, drain and wipe with a dry, clean cloth.
Weekly Maintenance
Empty any unused water from container. Rinse
container thoroughly, drain and wipe with a
dry, clean cloth.
Soak heating unit in 8 cm (3 inches) of white
vinegar for 10 minutes (Fig. 4). Use a butter
knife to gently remove any minerals from the
metal heater surface (Fig. 5). Access to the
heater surface can be obtained by lifting the
hinged cover on bottom of unit.
CLEAN THE HEATER SURFACE AFTER EACH
150 HOURS OF OPERATION.
Open hinged cover on bottom of heating unit
for access to the heater surface for cleaning
only. Use a butter knife to gently remove any
minerals from the metal heater surface. More
frequent cleaning may be required in hard-
water areas.
For proper operation, the cover must be shut
and in the correct position.
Instructions
CORD CAUTION: Unravel cord before use. Failure to do so could cause overheating and possible fire hazard.
DISCONNECT CORD: Always disconnects cord at wall plug before
removing the heating unit, filling, cleaning, or when not in use.
IMPORTANT: The heating unit will not operate unless the plug has
been disconnected from electrical outlet for about 1-2 minutes
prior to reconnecting.
REMOVE HEATING UNIT: Lift the rear of heating unit cap and
slowly rotate in a counter-clockwise direction until the slanted
portions of the two locking tabs is cleared. Then lift the heating
unit directly upwards until the locking tabs are clear of the water reservoir. (Fig. 1)
FILL THE CONTAINER: Fill container with tap water to the MAX water
level marked on the water reservoir.
DO NOT OVERFILL. (Fig. 2)
REPLACE HEATING UNIT: Align the two locking tabs on the side
of the heating unit with the two slots in the water reservoir. The
heating unit will only engage the water reservoir in the proper
orientation. Seat the heating unit into the locking tabs of the water
reservoir, then rotate the head clockwise to hold unit in place.
PLACE VAPORIZER IN STABLE POSITION: Vapourizer should
always be placed on a firm, flat surface at least 1.2 meters
(4 feet) from bedside. For safest operation, vapourizer should be placed on floor, where it cannot fall
or be pulled down. Be sure the power cord is out of the way to prevent vapourizer from being upset.
Protect floor, rug or furniture by placing the vapourizer on a non-metallic heat-resistant surface.
CAUTION: Do not direct steam flow directly at recipient, walls or furniture. Recipient will still obtain
desired level of humidity.
KEEP OUT OF THE REACH OF CHILDREN; STEAM CAN CAUSE BURNS. This appliance is not intended
for use by young children or infirm persons without supervision. Young children should be supervised to
ensure that they do not play with the appliance.
INHALANT STEAM ACTIVATED:
KAZ INHALANT or VICKS VAPOSTEAM can be filled is the medicine cup. Those products are not
delivered with the vapourizer but are available on some websites. You can use steam inhalants or
medicine oils brands available in drugstores and
pharmacies. For best results, fill the medicine
cup on the cap (located in the front of the of the
steam outlet vents) with the steam inhalant or
medicine oil product. DO NOT put this oil or steam
inhalant in the water tank, it must be put in the
medicine cup and not inside the tank. Any brand
or medicine into the water tank will damage the
unit and void the guarantee. (Fig. 3)
These inhalants are designed for use on one
vapourizer cycle (12-14 hours). After vapourizer
IMPORTANT SAFETY INSTRUCTIONS
Read through all the instructions before starting to use the appliance.
Keep this
manual in a safe place for future reference.
These instructions shall also be available on our website.
Please visit www.hot-europe.com.
This appliance must only be operated as instructed in this user manual.
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of
the appliance in a safe way and understand the hazards involved. Children shall
not play with the appliance. Cleaning and user maintenance shall not be made by
children without supervision.
This appliance is only designed for indoor use. Do not place it in direct sunlight,
high-temperature areas or near computers or sensitive electronic equipment.
Keep the appliance away from heat sources such as stoves, heaters, etc.
Place the appliance on a firm, even, non-metallic and waterproof surface. This
humidifier may not work properly on an uneven surface.
Kaz will not accept responsibility for property damage caused by water spillage.
Only connect the appliance to a single-phase AC supply to the voltage shown on
the rating plate.
Do not use an extension cord. Doing so could cause overheating, fire hazard or
electric shock.
Do not cover the mist outlet or put anything on it while the humidifier is running.
If surplus humidity forms condensation on walls and windows in closed or small
rooms, turn the power switch to the lower setting and open the door to the room.
Do not touch the hot steam. Steam can cause burns.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
Do not use this appliance if it is damaged or shows any signs of possible damage
or if it is not functioning properly. Disconnect the power plug from the power
socket.
This humidifier requires regular cleaning. Refer to the cleaning instructions.
Turn the humidifier OFF if you notice moisture on the inside of your windows.
For proper humidity reading use a hygrometer, which is available in many
hardware and department stores.
Never use the device with wet hands.
Never pull the cord, always pull the plug.
Always ensure that device is on a level surface.
Always ensure that the cable is fully unravelled and has no knots in it.
Fig.3
Fig.2
Fig.4
Fig.5
Fig.1
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Vicks VH188E - Warm Steam wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info