Always two impulse outputs are combined to a pair (red/green). The output pairs 1 to 4 are each
controlled by a push button pair of the Keyboard. A push on the green button will case an im-
pulse at the corresponding green socket of the decoder, a push on the red button generates an
impulse at the red output. The yellow socket is the common pole.
A special feature of the viessmann-decoder is the possibility to supply the switching power
separately at the red extra socket "E". You have the choice to use either the digital current (see
picture 1) or the current from an extra transformer (see picture 2).The second possibility re-
lieves your digital booster and assures a reliable switching of the turnouts and semaphores, if a
lot of trains are driving simultaneously. But therefore you have to connect one additional wire
between all decoders 5211.
2
von der
Zentraleinheit
bzw. vom Gleis
from the central
unit resp. from
the rail
Wichtig! Die Buchse E
immer anschließen!
Important! The “E”-
socket always have to
be connected!
Zu weiteren Decodern
to further decoders
zum Trafo
to a transformer
E
3
Viessmann
Weichendecoder 5211
Zur Erzielung der optimalen Schaltleistung ist es empfehlenswert, die Versorgung der “E”-
Buchse über das Powermodul 5215 vorzunehmen (siehe Seite 5).
Achtung!
Bei separater Schaltspannungseinspeisung (nach Abbildung 2) die rote Leitung "E" und
das rote Kabel des Digitalstromkreises nicht zusammenschalten! Lediglich die Masse-
leitungen (braun) werden gekoppelt.
Allerdings muß die rote Buchse "E" immer entweder nach Abbildung 1 oder Ab-
bildung 2 angeschlossen sein, da ansonsten vom Decoder keine Spannungsim-
pulse an dessen Ausgängen erzeugt werden können.
E
Achtung!
Alle Anschlußarbeiten sind nur bei abgeschalteter Betriebsspannung
durchzuführen!
Die Stromquellen müssen so abgesichert sein, daß es im Falle eines Kurz-
schlusses nicht zum Kabelbrand kommen kann. Verwenden Sie nur
handelsübliche und nach VDE/EN gefertigte Modellbahntransformatoren!
Attention!
Make sure that the power supply is switched off when you connect the wires !
The power sources must be protected to prevent the risk of burning wires. Only
use VDE/EN tested special model train transformers for the power supply!
Anschluß von viessmann-Formsignalen
How to Connect viessmann Semaphores
To achieve the optimum of switching power you should use the Viessmann power module 5215
to supply the “E”-socket. You can see it on page 5.
Attention!
If you use a separate transformer (like in picture 2) don't connect the red wire "E" to the
red wire of the digital current circuit. Only the ground wire (brown) have to be coupled.
But the red socket must always be connected like it is shown in pictures 1 and 2. If
you don't do this, the decoder isn't able to generate the power impulses at its
outputs.
4
_
~
16 V
AC/DC
Mittelleiter - Trennstellen
third rail insulations
_
~
16 V (AC/DC)
zum Lichttrafo
to the light transformer
z.B. 4502
und alle anderen
viessmann-Formsignale
mit zwei Antrieben
e.g. 4502
and all other viessmann
semaphores with two
motors
E
_
~
16 V
zum Lichttrafo
(AC/DC)
1,5 kOhm
1/4 Watt
1,5 kOhm
1/4 Watt
zum Gleis
to the rail
z.B. 4500
und alle anderen
Viessmann-Formsignale
Mit einem Antrieb
e.g. 4500
and all other
viessmann sema-
phores with only
one motor
To the light transformer
Viessmann
Weichendecoder 5211
Zu weiteren
Decodern
to further
decoders
zum Trafo
to a transformer
E
rot
red
braun
brown
braun brown
rot
red
16 V
AC/DC
~
-
rot red
braun brown
rot
red
rot red
braun brown
rot red
blau blue
blau blue
blau blue
gelb
yellow
blau
blue
braun
brown
rot
red
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

viessmann-5211

Suche zurücksetzen

  • Viessmann 5291 schaltet bei Ausgang 2 nur einseitig
    Eingereicht am 18-6-2020 12:03

    Antworten Frage melden
  • ich fahre 2-leiter mit intellibox und krieg viessmann 5211 nicht zum schalten. anschlüsse wie in gebrauchsanleitung. Eingereicht am 4-5-2018 10:15

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Viessmann 5211 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info