580301
1
Zoom out
Zoom in
Vorherige Seite
1/36
Nächste Seite
D-300885 1
PowerMaxComplete
Fully Supervised Wireless Alarm Control System
Installer Guide
TABLE OF CONTENTS
1. INTRODUCTION ....................................................... 3
2. SPECIFICATIONS..................................................... 3
2.1 General Data....................................................... 3
2.2 RF Section .......................................................... 3
2.3 Electrical Data ..................................................... 3
2.4 Communication ................................................... 4
2.5 Physical Properties ............................................. 4
3. INSTALLATION ......................................................... 4
3.1 Unpacking the Equipment................................... 4
3.2 Supplying Power to the Unit................................ 4
3.3 System Planning & Programming....................... 4
3.4 Mounting ............................................................. 4
3.5 Wiring .................................................................. 4
3.6 Backup Battery Insertion..................................... 7
3.7 Optional GSM Module Mounting ........................... 7
3.9 Optional Expander Module Mounting ................. 8
3.10 Power Cable Connection .................................. 8
3.11 Control Panel Final Closure............................ 10
4. PROGRAMMING..................................................... 11
4.1 INTRODUCTION .............................................. 11
4.1.1 General Guidance.......................................... 11
4.1.3 Installer’s Menu .............................................. 11
4.1.4 Setting a New Installer Code ......................... 11
4.1.5 Setting a New Installer Code in
PowerMaxComplete that has 2 Installer Codes....... 11
4.2 ENROLLING WIRELESS DEVICES AND KEYFOB
TRANSMITTERS......................................................... 12
4.2.1 General Guidance.......................................... 12
4.2.2 Enrolling Type ................................................ 12
4.2.3 Enroll/Delete Sensors .................................... 12
4.2.4 Enroll/Delete Keyfob Transmitters ....................... 12
4.2.5 Enroll/Delete Wireless Commander...................... 12
4.2.6 Enroll/Delete 2-Way Keypad .......................... 12
4.2.7 Enroll/Delete Wireless Siren........................... 12
4.2.8 Enroll/Delete Proximity Tags .......................... 12
4.3 DEFINING ZONE TYPES, NAMES & CHIME
ZONES......................................................................... 14
4.4 DEFINING CONTROL PANEL PARAMETERS.... 15
4.4.1 Preliminary Guidance..................................... 15
4.4.2 Entry Delays 1&2 ........................................... 15
4.4.3 Exit Delay ....................................................... 15
4.4.4 Bell Time ........................................................ 15
4.4.5 Abort Time...................................................... 15
4.4.6 Alarm Cancel.................................................. 15
4.4.7 Quick Arm ...................................................... 15
4.4.8 Bypass............................................................ 15
4.4.9 Exit Mode ....................................................... 15
4.4.10 Piezo Beeps ................................................. 16
4.4.11 Trouble Beeps.............................................. 16
4.4.12 Panic Alarm.................................................. 16
4.4.13 Swinger Stop................................................ 16
4.4.14 Cross Zoning................................................ 16
4.4.15 Supervision .................................................. 16
4.4.16 NOT READY ................................................ 16
4.4.17 AUX Button A ............................................... 16
4.4.19 Jam Detect................................................... 16
4.4.20 Latchkey....................................................... 16
4.4.21 “Not Active .................................................. 16
4.4.22 Back Light .................................................... 17
4.4.23 Duress.......................................................... 17
4.4.24 Piezo Siren................................................... 17
4.4.25 Reset Option ................................................ 17
4.4.26 Tamper Option............................................. 17
4.4.27 Siren On Line............................................... 17
4.4.28 Memory Prompt ........................................... 17
4.4.29 Disarm Option.............................................. 17
4.4.30 Bell/Rep. Option........................................... 17
4.4.31 Low-Bat Ack................................................. 17
4.4.32 Screen Saver ............................................... 17
4.4.33 Confirm Alarm .............................................. 17
4.4.34 AC FAIL REP ............................................... 17
4.4.36 User Permission .......................................... 17
4.4.38 Batttery Type................................................ 17
4.5 DEFINING COMMUNICATION PARAMETERS... 19
Preliminary Guidance.............................................. 19
4.5.2 Autotest Cycle................................................ 19
4.5.3 Area Code...................................................... 19
4.5.4 Out Access No............................................... 19
4.5.5 First Central Station Tel. ...................................... 19
4.5.6 First Account No. ........................................... 19
4.5.7 2
ND
Central Station Tel ..................................... 19
4.5.8 Second Account No. ...................................... 19
4.5.9 Report Format................................................ 19
4.5.10 4/2 Pulse Rate ............................................. 19
4.5.11 Reporting to Central Stations ......................... 19
4.5.12 Report CNF Alarm ......................................... 19
4.5.13 Send 2WV Code............................................ 19
4.5.14 Two-Way Voice Central Stations..................... 20
4.5.15 Ring Back Time ........................................... 20
4.5.16 Dialing Attempts........................................... 20
4.5.17 Set Private Tel. No.......................................... 20
4.5.18 Two-Way Voice - Private Phones.................... 20
4.5.19 Private Tel. Dialing Attempts ....................... 20
4.5.20 Reporting to Private Telephones ..................... 20
4.5.21 Tel. Acknowledge .......................................... 20
4.5.22 Pager Tel. No............................................... 20
4.5.23 Pager’s PIN No. ........................................... 20
4.5.24 Reporting to a Pager.................................... 20
4.5.25 Recent Closure ............................................ 20
4.5.26 Remote Access............................................ 20
4.5.27 Mast. DL Code ............................................. 20
4.5.28 Inst. DL Code ............................................... 22
4.5.30 Zone Restore ............................................... 22
4.5.31 Upload Option.............................................. 22
4.5.32 Dialing Method............................................. 22
4.5.33 Line Failure Report ...................................... 22
4.5.34 UL/DL Tel. Number...................................... 22
4.5.35 System Inactivity Report .............................. 22
4.5.38 Ambient Level .............................................. 22
4.6 DEFINING GSM PARAMETERS .......................... 22
4.6.1 GSM Module Installation................................ 22
4.6.2 1st, 2nd, 3rd & 4th SMS Number..................... 22
4.6.3 Reporting to SMS Phone Number .................... 22
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

visonic-powermax-complete

Suche zurücksetzen

  • wie kann man wechseln die baterie des gerätes NEXT®
    K9-85 MCW in alarm systen PowerMax Complet Visonic Eingereicht am 15-8-2020 13:06

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Visonic PowerMax Complete wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Visonic PowerMax Complete

Visonic PowerMax Complete Bedienungsanleitung - Holländisch - 48 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info