764164
5
Zoom out
Zoom in
Vorherige Seite
1/56
Nächste Seite
EN
5
WWW.VONROC.COM
Electrical safety
When using electric machines always observe the
safety regulations applicable in your country to
reduce the risk of fire, electric shock and personal
injury. Read the following safety instructions and
also the enclosed safety instructions.
Always check that the power supply
corresponds to the voltage on the rating
plate.
Connecting to the power supply
Check that the power supply and plug used in
accordance with your machine. Have a look at the
rating plate on the machine. Any changes should
always be carried out by a qualified electrician.
Warning! This machine must be earthed. If
not properly earthed this machine can cause
an electrical shock. Be sure that the power
supply outlet is earthed. If there is any doubt,
have it checked by a qualified electrician.
Warning! Avoid contact with the terminals
on the plug when installing (removing) the
plug to (from) the power supply outlet.
Contact will cause a severe electrical shock.
Replacing cables or plugs
Immediately throw away old cables or plugs when
they have been replaced by new ones. It is dangerous
to insert the plug of a loose cable in the wall outlet.
Using extension cables
Only use an approved extension cable suitable
for the power input of the machine. The minimum
conductor size is 1.5 mm. When using a cable reel
always unwind the reel completely.
2. MACHINE INFORMATION
The pump is intended for private use for draining
flooded house and garden areas but also for trans-
ferring water to and from tanks and pumping them
out, from drawing water from wells and shafts and
for draining boats and yachts. Explosive, corrosive,
flammable substances, sewage, salt water, grease
and oil must not be conveyed by the pump.
The particle sizes of the solids in the dirty water
must not exceed the maximum particle size speci-
fied in the technical data.
This pump is not designed for continuous operation
(e.g. as a swimming pool or pond circulation pump)
or for stationary installations (e.g. lifting device,
fountain pump).
TECHNICAL SPECIFICATIONS
Model No. SP501AC SP502AC
Application Clean water Clean or
dirty water
Floating switch Yes
Voltage 230 VAC / 50Hz
Input power 300W 400W
Max. flow rate 6500l/h 8000l/h
Max. pressure 0.6 bar 0.55 bar
Max. pumping height 6m 5.5m
Max.depth 7m
Max. particle size 5mm 25mm
Min. residual water height
(manual operation) * 5mm 20mm
Switch-on height (automatic
operation) ** 50cm
Switch-off height (automatic
operation) 5cm
Max. water temperature 35°C
Protection IPX8
Built-in thermal motor pro-
tector Yes
Output hose connection 25mm, 32mm, G1"
Recommended inner hose
diameter 32mm
Water outlet G1 ¼"
Cable length 10m
Weight 3.22 kg 3.28 kg
* The stated residual water height is only
achieved in manual operation.
** The switching height can vary depending on the
position of the float switch.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Vonroc SP501AC wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info