749863
1
Zoom out
Zoom in
Vorherige Seite
1/2
Nächste Seite
Digital Wrist Blood
Pressure Monitor
KP-6241
- Instructions for use -
12/2010
Introduction
thank you for deciding for the blood
pressure monitor KP-6241 from
Weinberger GmbH & Co. KG. To be able
to utilise all advantages of the blood
pressure monitor to the fullest, you
should carefully read these instructions
before using the monitor. Keep the
instruction leaflet in a safe place.
Safety instructions
The blood pressure monitor KP-6241
enables you to monitor your blood
pressure regularly. However, you should
never change the treatment which your
doctor has prescribed
Self-measurement means monitoring,
it does not imply diagnosis or
treatment.
Discuss unusual values with your doctor.
Do not change the medication
prescribed by your doctor.
The heart rate is not a useful indicator of
the frequency of a cardiac pace maker.
Patients with cardiac arrhythmia should
use the blood pressure monitor only after
consulting a doctor.
Features of the KP-6241
The blood pressure monitor has fuzzy
logic to identify the pumping pressure.
If the pumping pressure set in the
factory is not sufficient, the device
identifies this and continues pumping.
The device has 85 memory locations.
The date and time are displayed and
stored together with every blood
pressure value.
If the battery icon is displayed, the
batteries are discharged and the device
cannot be used until new batteries are
inserted.
WHO-Interpretation of blood pressure
readings with colored band (See
description at page 7).
- 2 -
The handcuff is suitable for wrists
from 135 to 195 mm circumference.
Preparing the monitor for
measurement / changing batteries
Insert the two supplied batteries in the
battery compartment at the side of the
blood pressure monitor as shown.
Use only alkali batteries (LR03).
If the batteries are depleted, the battery
icon is displayed in the top left corner
of the LC display. The battery needs
urgent replacement because you cannot
use the monitor with depleted batteries.
Device description
Setting the clock
After you have inserted the two batteries,
you should set the clock.
To set the clock, hold the TIME button
pressed for about 5 seconds. The year
blinks in the top right corner of the
display.
Set the year with the 0/I-START button.
- 3 -
When the correct year is set, press the
TIME button again. Now the 1 blinks in
the top right corner of the LCD. It stands
for the month.
Set the month with the 0/I-START button.
Another press of the TIME button sets
another 1 blinking. It stands for the first
day in the month.
Set the day with the 0/I-START button.
Another press of the TIME button takes
you to the clock setting the hours blink.
As earlier, set the clock with the 0/I-
START button.
Pressing the TIME button advances to
the minutes setting.
Set the minutes with the 0/I-START
button.
A final press of the TIME button
completes the setting of the date and
time.
How to obtain correct measuring
results
To obtain correct readings, measure the
blood pressure always
under the same
conditions, at rest, not
under the effect of
alcohol, not during
meals, not after heavy
physical or mental
stress. If possible, sit
down at a table for the
measurement.
Please note: The blood pressure monitor
must be at heart level during the
measurement, otherwise wrong readings
are obtained.
- 4 -
The measuring method
Put the cuff around your left wrist making
sure that the device rests on the artery
and the top edge of the device is about 1
cm away from the wrist joint (Please see
the enclose photo).
The cuff should be applied with moderate
tightness.
Pressing the 0/I-START button starts the
automatic measurement. The cuff inflates
to approx. 190 mmHg pressure.
The automatic deflation starts the
measurement. After about 3 seconds, a
heart icon starts blinking in the LC
display. If a Korotkoff’s sound is detected
already at that time, it means a
systolic pressure of more than 150
mmHg. Then the monitor re-inflates (to
about 220 mmHg). At the end of the
measurement, the result is displayed in
the LCD and the cuff deflates.
Aborting a measurement
You can stop the measurement at any
time by pressing the 0/I-START button.
The BP monitor deflates the cuff instantly.
- 5 -
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Weinberger KP-6241 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Weinberger KP-6241

Weinberger KP-6241 Bedienungsanleitung - Deutsch - 2 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info