INSTALLATION
GAS CONNECTION
1.
Check the “gas type” sticker attached to the hotplate. Details of the injector sizes used are recorded on the data plate
located on the base of the appliance.
2.
This appliance shall be installed in accordance with installation requirements of the local gas authority to the appropriate
installation code (AS5601).
3.
Before installing the hotplate consider the location of the gas supply and routing the gas line. (Refer Fig. 1).
4.
For ULPG models the gas supply for the hotplate must be regulated to a pressure of 2.75kPa. The gas inlet connection
fitting is ½” B.S.P female thread.
5.
For NG models the gas supply is connected to a regulator which is supplied. The inlet connection has ½” B.S.P female
thread. IT IS ESSENTIAL THAT THE ELBOW ON THE APPLIANCE BE HELD FIRMLY WITH A SPANNER. DO NOT
OVER TIGHTEN. The regulated pressure for NG is 1.00kPa.
6.
A manual shut-off valve must be installed in the gas line, in an accessible position external to the hotplate, so that in the
event of an emergency or service, the gas supply can be shutoff.
7.
For gas inlet position of appliance refer Fig. 2 for NG and fig.3 for ULPG. After installing the gas supply and making all
connections check thoroughly for possible leaks. Turn all control knobs on the unit to “OFF” position. Open the valve
on the gas supply. Using a soap and water solution check each gas connection one at a time, by brushing the solution
over connection. Presence of bubbles will indicate a leak. Tighten the fitting and re-check for leaks. If it is not possible to
correct the leak, replace fitting. Under no circumstance use matches or flame for checking leaks.
8.
Turn on appliance gas cock and light each burner. Check for a clear blue flame without yellow tipping. If burners shows
any abnormalties check the following:
- Burner cap on correctly
- Burner positioned correctly
- Burner vertically aligned with injector nipple
9.
In some cases the burners will fail to ignite immediately and will seem to 'blow's lightly when they do ignite, this is usually
due to air in the gas pipe which should clear itself within seconds of operation.
10.
If after following the instructions given, satisfactory performance cannot be obtained, contact the local gas authority for
advice and assistance.
ELECTRICAL
CONNECTION
POINT
GAS
CONNECTION
POINT
Fig. 1
Fig. 2
Fig. 3
ELECTRICAL CONNECTION
The electrical connections must comply with
local regulations.
The data relevant to the voltage and power
absorption are indicated on the rating plate.
The earthing of this appliance is compulsory by
law.
The manufacturer cannot be held responsible for any injury to persons or animals or damage to property
arising from failure to comply with these requirements.
When the hob is installed, provide a single-pole circuit breaker with a contact separation of at least 3 mm.
If necessary, the electrical power cable must be replaced exclusively with a power cable having identical
characteristics to the original supplied by the manufacturer (type H05V2V2-F T90°C or H05RR-F).
This operation must be performed by a qualified electrician.
ASSEMBLY
After having cleaned the perimeter surface, apply the supplied gasket to
the hob as shown in the figure.
Position the hob in the worktop opening made respecting the dimensions indicated in the Product Description Sheet.
Note: the power supply cable must be long enough to permit its upward extraction.
To secure the hob, use the brackets (
A
) provided with it.
Fit the brackets into the relevant bores shown by the
arrow and fasten them by means of their screws in
accordance with the thickness of the worktop (see figures
on the right).
Earth
(yellow/green)
L
N
00 - BLACK
11 - BROWN
22 - RED
33 - ORANGE
44 - YELLOW
55 - GREEN
66 - BLUE
77 - VIOLET
88 - BLUE SKY
99 - WHITE
09 - WHITE-BLACK
29 - WHITE-RED
49 - WHITE-YELLOW
69 - WHITE-BLUE
90 - GREY
45 - YELLOW-GREEN
N6 : SPARK IGNITION SWITCH (UNDER KNOB)
Q : SPARK IGNITION PLUG
W/PI: MAINS TERMINAL BLOCK/SPARK IGNITION
X2 : COOKTOP EARTHING
WIRING DIAGRAM
230 - 240 V
Top 40 mm
To p 3 0 m m
Top 20 mm
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Whirlpool AKT 306 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info