AIR CLEANER SET-UP
Set-Up Procedure
1. Remove protective film from the control
panel.
2. Remove the front panel by pulling gently on
the lower portion of the panel.
Do not force, the panel should remove easily.
3. Grasp tabs located on each side of filter and
pull out the filter gently.
4. Remove the plastic wrap from the filter.
5. Return the filter to the air cleaner unit.
6. Cover the front panel after pressing the filter
change reset button.
7. Plug the power cord into a wall outlet.
8. Press and hold the POWER button until a
short “beep” sounds.
9. The air cleaner will take 3~4 minutes to
calibrate the AIR QUALITY sensor. During this
time the sensor lights will flash on and off.
Once the sensor has calibrated, the lights will
begin in AUTO mode.
10. Remove tab from remote control
(WACU300 / WACU450 only.)
Note: For best results and to maximize air flow:
Place unit at least 2 feet away from the wall.
Place the unit away from drafty areas, as the
sensors may not react accurately.
Do not place near curtains, furniture, or
other items that might inhibit air flow.
Place the unit on a stable surface.
AIR CLEANER FEATURES
CAUTION: Fully assemble air filter before using (See Air Cleaner Set-Up on following page).
Note: Features vary according to model.
Quiet Operation
This Winix air cleaner has a four-speed fan
with quiet operation that is ideal for night
time use.
Air Quality Sensor
This Winix air cleaner has an AIR Quality
sensor that detects the presence of various
pollutants in the air. The unit automatically
increases fan speed to clean more air
volume and remove the impurities quickly.
Light Sensor
The built-in light sensor allows undisturbed
sleep with a very smart ‘Sleep Mode’
option. When Sleep Mode is selected the
light sensor will detect when the room is
dark and automatically dim the control
panel lights and lower the fan speed to the
whisper quite setting. Lights will remain dim
and fan will remain at the low speed until
the room is light.
Multi-Stage Cleaning
The air passes through multiple stages of
cleaning before returning to the room.
PlasmaWave™ Technology
Safely breaks apart odor, allergens,
chemical vapors and other pollutants at
the molecular level - without producing
harmful ozone.
True HEPA Filter
Captures 99.97% of airborne
pollutants, pet dander and
allergens as small as 0.3 microns
and can be safely washed when
washing the washable pre-filter
and carbon filters.
Washable AOC™ (Advanced
Odor Control) Carbon Filter
Especially formulated to
capture offensive Pet Odors;
as well as Smoke, Cooking
and other Household Odors.
Washable Pre-Filter
The Washable Anti-Bacterial
Pre-filter extends the life of your
filter by capturing Pet Hair and
larger airborne particles and
makes housecleaning easier.
Advanced PlasmaWave™ Technology
PlasmaWave™ breaks apart airborne pollutants at the molecular level.
In a fraction of a second, PlasmaWave™ combines with naturally occurring water molecules
in the air (H
2
O) to create billions of Hydroxyl Radical molecules (OH).
OH is an unstable molecule that seek equilibrium by stealing hydrogen atoms from adjacent
molecules containing hydrogen (the pollutants), thereby reforming them into harmless
molecules of water, carbon dioxide, and other acceptable molecules.
The result is a measurable reduction of pollutants after the air passes through the Plasma
Generator (PlasmaWave™).
By reforming molecules, PlasmaWave™ technology can reduce odors, as well as VOCs
(chemicalvapors). It is also effective at reducing airborne.
The PlasmaWave™ technology is harmless and the OH molecule only lives for a
nanosecond while it reforms surrounding molecules. Most importantly-unlike old style ion
technology-PlasmaWave™ dose not produce high levels of ozone as a by-product.
When combined with a fan-and-filter air cleaning system, PlasmaWave™ offers an effective
and efficient way of cleaning the air of unwanted pollutants including dust, smoke, and
pollen, as well as VOCs, allergens, and odors.
9 10
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Winix U300UK wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info