564201
5
Zoom out
Zoom in
Vorherige Seite
1/62
Nächste Seite
GB
7
Heating timer-thermostat
Parameter
Description
Programmable
values
UT01
OFF; Day 1, ...,Day7
H. timer-thermostat ena-
bling and disabling. Day of
the week setting
UT02
From 00 to 23Current hour setting
UT03
From 00 to 60
Current minutes setting
UT04
Reserved
Technical parameters setting
UT05
From 00:00 to 23:50 with
10-minute steps
Pellet boiler stove first start-
up time adjustment
UT06
From 00:00 to 23:50 with
10-minute steps
Pellet boiler stove first shut-
down time adjustment
UT07
Between on/off for days
from 1 to 7
Week day selection, first
time activation
UT08
From 00:00 to 23:50 with
10-minute steps
Pellet boiler stove second
start-up time adjustment
UT09
From 00:00 to 23:50 with
10-minute steps
Pellet boiler stove second
shutdown time adjustment
UT10
Between on/off for days
from 1 to 7
Week day selection, second
time activation
UT11
From 00:00 to 23:50 with
10-minute step
Pellet boiler stove third
start-up time adjustment
UT12
From 00:00 to 23:50 with
10-minute step
Pellet boiler stove third shu-
tdown time adjustment
UT13
Between on/off for days
from 1 to 7
Week day selection, third
time activation
UT14
From 00:00 to 23:50 with
10-minute steps
Pellet boiler stove fourth
start-up time adjustment
UT15
From 00:00 to 23:50 with
10-minute steps
Pellet boiler stove fourth
shutdown time adjustment
UT16
Between on/off for days
from 1 to 7
Week day selelction, fourth
time activation
The meaning of the user parameters are explained in detail
below:
UT01
Heating timer-thermostat enabling and disabling and
current hour setting.
This parameter is used to set the current day of the week or
to deactivate the set programming.
Press buttons and to select the desired value as
shown in the following table:
Upper
Display
MEANING
Day 1
Day 2
Day 3
Day 4
Day 5
Day 6
Day 7
OFF
Example:
if today is Thursday, select “Day 4”; but select “OFF” to
start the pellet boiler stove manually (without programming)
so that the heating timer-thermostat is disabled.
Press button to go to the following parameter.
UT02
Current hour setting
This parameter is used to set the current hour, press
buttons and to select the current hour.
Press button to go to the following parameter.
UT03
Current minutes setting
Press buttons and to adjust current minutes.
Press buttons to go to the following parameter.
UT04
Technical parameters setting
Press button to go to the following parameter.
The heating timer-thermostat function is used to program
the pellet boiler stove to automatically turn on and off within
a period of one week.
To access programming, hold down button for around
three seconds, “UT01” will be shown on the upper display:
by pressing button several times and referring to the
table below, the stove can be programmed according to
your needs. Press button to exit the programming phase
at any time.
These are the heating timer-thermostat parameters:
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Heating timer-thermostat disabled
Monday
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Zibro DONATA 124 IDRO wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info