Archiving the Console Settings
The console settings can be saved to an external
device such as a MIDI sequencer or data archiver
using the dump out facility. Settings can be loaded
back into the console using dump in. This is ideal
when you want to archive the settings to use at a
later date, for example a re-run of a previous
performance. You can also use the dump facility to
program additional ML3000 consoles, for example
when setting up duplicate shows or swapping
consoles around. Simply link MIDI OUT from one to
MIDI IN of the other and action the dump out facility.
Settings which are archived :
9 Current mute settings
9 Current Mute group assignments
9 Current VCA group assignments
9 All snapshot memories
Settings which are not archived :
8 Current console operating mode
MIDI Dump Out
Connect the console to a suitable MIDI archiving
device. Set the same MIDI channel number on
both. Check the rear switch is set to MIDI. Press
the MIDI and VIEW keys together. The console
dumps the current settings and memory contents
using a SysEx message string. During this time the
MIDI LED lights to show that data is being sent via
the MIDI port. Note that this operation can take up
to 10 seconds during which time the console mutes
and assignment operations are interrupted.
MIDI Dump In
Connect the console to the MIDI archiving device.
Set the same MIDI channel number on both. Check
the rear switch is set to MIDI. Start the process
using the MIDI archiver. The console current
settings and memory contents are overwritten.
During this time the MIDI LED lights to show that
data is being received by the console. Note that this
operation can take a while during which time the
console mute and assignment operations are
interrupted.
If you are using a MIDI sequencer to record the
dump out data string then make sure you play it
back at the same speed you recorded it. If you
dump it back into the console faster than it was
recorded some data may not load correctly.
MIDI Dump Message Format
The format for dump out and in is identical. The
dump data string is made up of multiple System
Exclusive messages (known as packets) which
contain the console information.
Transmit and Receive. The format for a single
packet is as follows:
F0 <SysEx header> <packet type> <packet
number> <data> <checksum> F7
<SysEx header> = 00 00 1A 50 07 VV vv nn
Where VV = software version number – major
vv = software version number – minor
nn = console MIDI channel number
<packet no.> = packet number from 0 to 127
<data> = block of console data (7-bit format)
<checksum> = checksum to allow error detection
MIDI Dump Errors
If the console or connected equipment fails to
respond to a MIDI dump then check:
The MIDI cable is good and correctly plugged
The correct MIDI channel number is selected
The console rear panel switch is set to MIDI
Try again
Allen & Heath ML Archiver
The ML Archiver Windows™ utility for the PC can
be downloaded from the Allen & Heath Internet site.
This can be used to archive data to and from the
PC via MIDI or RS232.
The program also includes the useful Snapshot
Manager which lets you store and recall the console
mute settings and VCA group assignments from the
128 internal snapshot memories. The snapshots
cannot be accessed from the console control panel
itself. The archiver provides this extra feature.
Check the Allen & Heath Web site for further details
and loading instructions.
44

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Allen-Heath ML 3000 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info