519942
5
Zoom out
Zoom in
Vorherige Seite
1/32
Nächste Seite
2. Change to the next measuring mode by pressing the key #
within 3 seconds.
3. Once you have selected your desired measuring mode wait
for approx. 4 seconds until the symbol ceases flashing.
Then, the selected measuring mode is active.
Note: Firstly measure on dry material and then compare the
values with the material to be measured to get a sense for the
measured values. To be able to evaluate the moisture distribu-
tion within the material measure on different points.
Building moisture measurement
1. Select the
symbol.
2. Remove the protective cap .
3. Exert slight pressure to press the puncture probes on the
material.
4. The display will show the measured value and a LED lights.
LOW (green) = 0.3 – <0.6%
MID (yellow) = 0.6 – <0.9%
HIGH (red) = >0.9 – 2.0%
5. Reattach the protective cap after completion of the meas-
urement.
4
Wood moisture measurement
1. Select the
symbol.
2. Remove the protective cap .
3. Stick both probes into the material (approx. 3 - 4 mm).
4. The display will show the measured value and a LED lights.
LOW (green) = 8 – <14%
wood is dry and suited as firewood,
no rotting
MID (yellow) = 14 – <20 %
marginal wood moisture,
further checks required
HIGH (red) = >20 – 60 %
wood moisture too high,
wood not suited as firewood,
risk of rotting
5. Reattach the protective cap after completion of the meas-
urement.
Temperature measurement
1. Select °C or °F.
2. The display will indicate the ambient temperature.
Switching off
The moisture measuring device will automatically switch off
after approx. 1 minute if no more measurements are made.
Display lighting
Press the key # to activate the display lighting for approx. 15
seconds.
Maintenance and cleaning
After measurement, clean the probes and the case using a clean
cloth.
Never use cleaning agents or solvents. Otherwise the device
may be damaged irreversibly. Plastic parts may be corroded by
chemicals.
Disposal
Give devices, accessories and packaging to an ecofriendly
recycling.
For EU countries only.
Electrical devices do not go into the domestic
rubbish.
According to the European Directive 2002/96/EC on
electrical and electronic scrap, electrical devices that
are no longer serviceable must be separately collected and
brought to a facility for an environmentally compatible recycling.
Disposal of non-usable batteries
Batteries/accumulators do not fall under domestic
rubbish.
According to the European Directive 2006/66/EC on
batteries and rechargeable accumulators, defective batter-
ies/accumulators must be recycled. Bring batter-
ies/accumulators, which are no longer usable, to local collecting
points or dealers.
Technical data
Measuring
range:
Resolution: Accuracy:
Building mois-
ture
0,3 – 2,0 % 0,01 % ± 0,1 %
Wood moisture
8 – 60 % 0,1 % ± 2 %
Temperatur:
°C
°F
0 – 40 °C
32 – 99 °F
0,1 °C
0,2 °F
± 2 °C
± 4 °F
Voltage supply: 9V (1x 6LR61 / 6AM6)
Operating conditions: 0 – 40°C
<85% rel. humidity of air
Storage conditions: -10 - +50°C
<85% rel. humidity of air
Weight (without battery): 93 g
Dimensions (L x W x D) approx. 145 x 60 x 31 mm
EC Declaration of Conformity
according to EC directive 2004/108/EG
We,
ATIKA GmbH & Co. KG
Schinkelstraße 97 – 59227 Ahlen - Germany
herewith declare under our sole responsibility that the product
Moisture measuring device FM 2
is conform with the above mentioned EC directive.
Following harmonized standards have been applied:
EN 55014-1:2006; EN 55014-2/A2:2008
Keeping of technical documents at:
ATIKA GmbH & Co. KG - Technical department
Schinkelstraße 97 - 59227 Ahlen - Germany
Ahlen, 22.01.2010 A. Pollmeier, management
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Atika FM 2 Vochtigheidsmeter wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info