77
POWER SUPPLY PANEL
1 - Open the transparent cover by pushing the two teeth in
its lowest corners to the direction indicated by the arrows.
4 - Close the transparent cover.
3 - Check the value of the new fuse to assemble, then fix it by
gradually and alternately fastening the two screws. This will
avoid voltage drops along the line and will make the device
perfect functioning easier.
2 - Remove the screws which fasten the fuse to eliminate
pieces of the broken one; prevent them from going into the
device.
FUSE REPLACEMENT
ACCESSORIES
14
This cooling system is specially designed to provide LRx amplifiers with the right working
temperature.
CLK2 should be used when LRx amplifiers work in extremely hard conditions (very low loads) or in
installations where space is too narrow and heat sink cooling is not enough. It consists of two units to
apply onto the amplifier sides; each of them is provided with an electronically controlled fan. Its
intervention depends on a thermal sensor that starts the system as soon as LRx heat sink reaches
45°C. The same sensor is connected to a special circuit which controls the two fans speed progressive
increase when temperature increases, too.
Air flux constant control allows the amplifier very good thermal stabilization and limits noise.
CLK2 – LRx Cooling Kit