MEASUREMENT INTERVAL
Powered by DC adapter
The device measures PM2.5 or PM10 concentration every minute automatically when
powered with a DC adapter.
Manual detection
User can press [CHECK] button anytime to get an updated measurement of PM2.5 or PM10
concentration readings. (It takes approximate 10-12s to detect, the readings indicated by
blinking PM2.5/PM10 icon.)
Operated by batteries
When powered by batteries, it’s detecting every 10 minutes by default. To maximize the bat-
tery life, user can also change the detection interval from 10 minutes to 20 or 30 minutes.
Setting default mearurement interval
1. Press and hold [CHECK]for2secondsuntilthedisplayisashing
2. Press [MODE] to choose which interval time.
3. Thesettingsequence:10m‣20m‣30m
4. Press [CHECK]tonishthesettingandgobacktonormaldisplay.
Detection interval (Minute) Description
1 (when connected to adapter) The sensor will detect the PM value every 1 minute
10 (default) The sensor will detect the PM value every 10 minutes
20 The sensor will detect the PM value every 20 minutes
30 The sensor will detect the PM value every 30 minutes
PM2.5/PM10 CONCENTRATION
For easy visualization of air quality, the device spreads the concentration readings over 6 level scale.
The following provides some given health guidelines on activities between good and
hazardous air quality*:
PM2.5 PM10 Healthy persons Elderly, Children,
Pregnant Women Persons with chronic disea-
se or heart disease
0~35 0~35 Continue with normal activities Continue with normal activities Continue with normal activities
36~53 51~75 Continue with normal activities Continue with normal activities Continue with normal activities
54~70 76~100 Reduce prolonged or strenuous
outdoor physical exertion
Minimize prolonged or strenuous
outdoor physical exertion
Minimize prolonged or strenuous
outdoor physical exertion
71~150 101~350 Avoid prolonged or strenuous
outdoor physical exertion Minimize outdoor activity Avoid outdoor activity
151~250 351~420 Minimize outdoor activity Avoid outdoor activity Avoid outdoor activity
251+ 420+ Avoid outdoor activity Avoid outdoor activity Avoid outdoor activity
Good
Hazardous
* Always consult/check with your doctors for any medical advices concerning the air quality and your health.
Note:
This 6 level scale of PM2.5 / PM10 concentration is not the same as Air Quality Index (AQI).
BATTERY POWER STATUS
The device is powered by rechargeable batteries, and comes with battery power indicator.
The battery life of the device from fully charged batteries is determined by the number of
detections it performed, either through set intervals or manually activated by user.
100% 80% 60% 40% 20% < 20%
When battery power fails to below 20%, user should recharge the batteries by connecting to
a USB port using the cable provided.
Note:
When the wireless PM2.5/PM10 air quality sensor’s battery power is below 20%, its
detection function will temporary suspension.
CHARGING BATTERY
You can use the micro USB cable to charge the wireless PM2.5/PM10 sensor if the battery
states show in “Low battery”. When Micro USB port plug in the micro USB cable for
charging, the LCD will display andashingbatteryicon.
:
:
Charging underway
Charged to full capacity
Note:
- Charged to full capacity from <20% battery power status require 24 hours.
REPLACE THE RECHARGEABLE BATTERIES
Over time, the batteries may degrade in terms of holding the highest capacity for which it
wasdesignedfor.Ifyoundthedevice´sbatterypowerisnotlastingasitusedtobe,it´s
probably a good time to change them.
1. Unscrew and
remove the battery
door of sensor with
a screwdriver.
2. Pull the black ribbon
lying under the bat-
teries. All batteries
can be removed
together.
3. Insert new 3 x AA size rechargeable batteries into the battery compart-
ment according to the polarity mark inside battery compartment.
4. Screw the battery door compartment on tightly.
5. After inserting batteries, all LCD segment will be shown for 1 second.
Note:
Please prepare a screwdriver for removing and close the battery door.
PAIRING WIRELESS SENSORS TO CONSOLE DISPLAY
This Wireless PM2.5/PM10 Air Quality Sensor can connect to the Air Quality Display console.
1. After powering up the wireless air quality sensor, it will automatically enter
registration mode for 10 minutes until which it can be paired by the display console.
2. Once the connection is successful, the signal strength indication and PM2.5/PM10
infromation will appear on the display console.
Note:
- If you need to re-assign the sensor channel, slide the channel slide switch to the new
cahnnel position, then use a pin to press [RESET] key to restart the sensor.
- To avoid the sensor(s) and console pairing failure during new channel number assigned
andsetup,pleasepowerupthesensor(s)rst,andthenpress[SENSOR]keyonthemain
unit.
- After connected to the console display, the reading will transmit every 12 seconds in the
rst5minutes.Everyreadingtransmission,thesymbolofsignaltransmission , will
ash0.5secondsatonce.
VIEW DATA ON CONSOLE
You can view the readings of your PM2.5/PM10 sensor(s) on the console receiver to which
the sensor(s) is linked to. Readings can then be analyzed into averages of past 24 hours or
maximums of past 1 hour, 24 hours, or since its last reset.
DATA TRANSMISSION
Thedevicetransmitsitsupdatedreadingatxedintervalof60secondstothepaired
console receiver.
RESET THE SENSOR
In case of malfunction, use a pin to press [RESET] button to reset the sensor.
SENSOR INSTALLATION
The sensor is designed for desktop or wall mount for easy viewing. Follow the guidelines
below for the sensor placement.
1. Choose an open area away from any emissions source of pollutants, heat source, or
withairowgreaterthan1m/s.
2. Place the wireless PM2.5/PM10 sensor at least 1.5m to 4m above the ground to better
illustrate the detection of air quality in the human breathing zone.
3. Do not expose the sensor to direct sunlight.
Wall mounting
Sensorcanbemountedonthewallatdierent
angle, either at slant angle or vertically with the
mounting adapter (included).
Place a screw on the wall where you wish to hang for sensor. Hand the sensor on to the
screw with or without the mounting adaptor.
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bresser 7009970 Air Quality Sensor wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info