471168
10
Zoom out
Zoom in
Vorherige Seite
1/12
Nächste Seite
11.Remove the hood from the lower bracket.
12.Drill at the point marked (Ø8mm) (Fig. 12).
13. Insert 1 or 2 wall screw anchors according to requirement.
14.Apply the flues support bracket G to the wall adherent
to the ceiling, use the flues support bracket as a
perforation diagram (the small slot made on the support
should coincide with the line previously traced on the
wall) and mark two holes with a pencil. Make the holes
(Ø8mm), and insert 2 dowels (Fig. 13).
15.Fix the chimney support bracket to the wall using two
5x45mm screws.
16.Hook the hood onto the bottom bracket.
17.Fix the hood into its final position on the wall
(ABSOLUTELY ESSENTIAL) (Fig. 14).
18.Connect a pipe (pipe and pipe clamps not provided, to
be purchased separately) for discharge of fumes to the
connection ring located over the suction motor unit.
If the hood is to be used in ducting version, the other end
of the pipe must be connected to a device expelling the
fumes to the outside. If the hood is to be used in filter
version, then fix the deflector F to the chimney support
bracket G and connect the other extremity of the pipe
to the connection ring placed on the deflector F (Fig. 15).
19.Connect the electricity.
Attention: only the models illustrated in Fig. 1Q:
Continue from the installation sequence number 23.
20.Apply the chimney stacks and fasten them at the top to
the chimney support G (20b) using 2 screws (20a)
(Fig. 16).
Only for model with optical fibers point lighting
(Fig. 1G):
Check that the chimneys may be removed to permit
access to the optical fibers lamp housing area.
Only for the model with control panel on chimney
flue (Fig. 1L- 17):
Insert the command plate from the motor group through
the chimney flue slit from the inside towards the outside
(20c).
Carry out the connection of the control panel to the
command plate.
Attention! The terminal pivot on the plate MUST
correspond to the drill hole on the connection
block situated at the back of the control panel.
21.Slide the bottom section of the chimney down until it
completely covers the suction unit and slots into the
housing provided on top of the hood (Fig. 18).
22.Fix the lower section of the chimney with two screws
(only for the model in Fig. 1H/19H-1J/19J-1L/19L-1M/
19M-1N/19N-1O/19O-1P/19P).
23.Only the models illustrated in Fig. 1Q:
Put the flues unit on the suction unit.
Connect the electricity between the two parts (Fig.
9).
Fix the flue units definitively to the suction unit with
the screws (consult the figure corresponding to the
model in possession) (Fig. 8Q).
Attention! Check that the lower section of the flue fits
onto the central bracket (Fig. 20).
Fix the upper section of the flue units to the flues
support bracket with two screws (Fig. 16).
Remount the carbon filter frame and the fat/s filter/s and check
the perfect functioning of the hood.
Electrical connection
The electrical tension must correspond to the tension noted
on the label placed inside the cooker hood. Connect the
electrical plug, where provided, to the an easily accessible
outlet in conformity with local standards in force.
Where an electrical plug is not provided (for direct connection
to electrical network) place a standards approved bipolar
switch with an aperture distance of not less than 3mm
(accessible) from the contacts.
Description of the hood - Fig. 1
1 Control panel
2 Grease filter
3 Grease filter release handle
4 lamp
5 Vapour screen
6 Telescopic chimney
7 Air outlet (used for filter version only)
8 point lighting (only for the model in Fig. 1G)
Operation 
All cooker hood versions
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction
is switched on for 5 minutes prior to cooking and to leave
in operation during cooking and for another 15 minutes
approximately after terminating cooking.
Operation 
Model with button panel
A. on/off light switch
B. on/off aspiration switch and minimum power selection
B+C. medium power selection aspiration switch
B+D. maximum power selection aspiration switch
a. ON/OFF lighting
b. OFF motors
c. - d. - e. Minimum suction power (c.), medium (d.),
maximum (e.).
f. Operation warning light (where present).
ABCD
a
a b-c
d
e
f
b-c-d-e
b-c-d-e
a
a
b
c
d
e
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Elica Optica wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info