The emergency number can be entered by:
99 xx...x F0
where:
xxx…x is a telephone number (max. 20 digits), enter F9 before the number if you
need + prefix for international calls
4.6. Remote programming of the alarm via SMS
The command PRG is used for sending programming and operating commands to the alarm system.
It has the same effect as if the commands are entered on the alarm system keypad. Enter the following
command :
yyyyyPRGseq,seq,seq,
where:
yyyyy is the remote access code; factory default setting is 1111; this code can be changed,
see section 4.1
PRG is the command identification
seq are the programming or operating sequences, consisting of characters 0 to 9, F, N.
There can be more than one sequence in one SMS. The particular sequences must
be separated with a comma or period. The number of sequences in one SMS is only
limited by the maximum size of the SMS in the GSM network.
separator (asterisk or space)
Example: if the control panel is disarmed and its master code is 1234, then if you want to set user code #2
for the alarm system, use the following command SMS: 1111
PRG
F61234 02 6789
After receiving this command message, the new user code (6789) will be added into the control panel.
4.7. Prepaid SIM cards
The JA-60GSM communicator can send information about the credit of a prepaid SIM card. An SMS
sent from any of the stored numbers (sequence 7t...) containing the word CREDIT followed by the
correct instruction (different for every provider) will result in the sending of the information about the
credit. Please ask your mobile phone provider for more information.
If you want to check the credit regularly use the following sequence.
CREDIT uuu..u xx yyy zz
where: uuu…u is the instruction given by the provider for receiving information about the amount
of credit
xx is the time period (in days) for every checking.
yyy is minimum level of credit
zz is a position of the credit in the information SMS sent by the provider
If the level of the credit is lower than set value (zz) the event “battery discharged GSM communicator”
will be sent to the preset telephone numbers. If the credit is restored the event “battery OK GSM
communicator” will be sent to the preset telephone numbers. To disable this function set the time (xx)
period to 00.
Note:
The user is responsible for the level of the credit
The producer does not recommend the use of prepaid cards.
User manual JA-60GSM - 3 - MFJ51808
Notes:
The system confirms an AM command with a reply SMS.
When system arming is impossible e.g. it is in the programming mode, you will be notified about the
situation via a reply SMS.
If the alarm system is “split” the instruction will effect the section which belongs to the corresponding access
code
If arming without a code is enabled on the control panel, the AM command can be used without any access
code. In this case the command performs the same action as if the keys F 1 are entered on a keypad.
1.6. Disarming via SMS (DM xxxx)
Command DM followed by a valid access code disarms the system. If the system is already
disarmed the command will be ignored.
Send SMS text to the dialer: DMxxxx
xxxx is a valid alarm system access code (Master or user)
separator (asterisk or space)
Example: Sending of DM
1234 will disarm the system in the same way as if the code 1234 is entered for
disarming on system’s keypad.
Notes:
The system confirms disarming via a reply SMS
When system disarming is impossible – for example it is in the programming mode, you will be notified
about the situation via a reply SMS.
If the alarm system is “split”, the instruction will effect the section which belongs to the corresponding access
code
If the alarm system is split and the command (AM or DM) is followed by the user code, it will effect the
system the same way as if the code is entered from the alarm system keypad – no matter if AM or DM is
used (it will arm if the system is disarmed and it will disarm if the system is armed).
1.7. Mode request via SMS (MO)
Command MO can be used to read the current alarm system mode. The dialer will reply with a
reporting SMS to the phone which sent the MO command about status, level of GSM signal, GPRS
status, successfulness of transferring date to the CMSs .
Send SMS text to the dialer: MO
Example: If the system is armed, it will reply to the MO instruction with the SMS: Alarm system
reports: Control panel status: Armed,GSM:7,GPRS OK,MS1 NOT,MS2 OK
Note: if you want to protect this command by a password, set your own command text – see section 3.3.
1.8. Last event request by SMS (ME)
Instruction ME is used for reading the last event recorded in the alarm system’s memory. The dialer
will reply with a reporting SMS.
Send SMS text to the dialer: ME
Example: After a fire alarm, it will reply to the ME instruction with the SMS “ Alarm system reports:
Last event: Alarm end Control panel Time: 02.06. 19:48 “
Note: if you want to protect this command by a password, set your own instruction text – see 3.3.
1.9. Remote controlling of an appliance via SMS (AUXON, AUXOFF)
These commands can be used for operating the AUX output (e.g. heating in a house). The dialer
confirms the command performance via a reply SMS.
To switch on the AUX output, send SMS text: AUXON
To switch off the AUX output, send SMS text: AUXOFF
To switch on the PgX(Y) output, send SMS text: PGON
To switch off the PgX(Y) output, send SMS text: PGOFF
Example: to switch the heating on send SMS: AUXON
Note: texts of these commands can be customized and protected by a password – see section 3.3.
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Jablotron JA-60GSM wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Jablotron JA-60GSM

Jablotron JA-60GSM Installationsanweisung - Englisch - 11 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info