terminals (max. 0.5A). The IW output status is also
transmitted for the wireless IW siren.
The difference between the internal warning (IW) output function and the
external warning (EW) one lies in their behaviour during the entrance delay
period. If any instant reaction detectors are triggered during the entrance
delay period, (e.g. by a child running straight to the living room during
disarming), only an internal warning is triggered. An external warning follows
only if the entrance delay has been exceeded (but no longer than 30
seconds).
PGX, PGY a pair of programmable outputs. When activated, the outputs
switch to GND, with a maximum load of 0.1A/12V. The
factory-default setting of PGX is the ON/OFF function
(operated by the instruction 81 / 80 or using
ON and
#OFF keys). PGY is activated if any part of the system is
armed. The status of PG outputs is also transmitted to AC
and UC wireless output modules by the control panel.
GND common ground connection
A,B E-LINE digital bus data signals. The bus output can be routed
outside the control panel box.
+L back-up power supply (10 to 14V) feeding the devices on the
E-LINE bus (e.g. a wired keypad), electronic fuse, max.
intermittent load 200 mA.
JA-83K control panel installation manual - 4 - MKG51101
3.2 Hard-wired inputs on the main board
There are hard-wired input terminals for 01-10 device addresses on the
main board. All hard-wired inputs act identically: double balanced loops which
sense loop stand-by, activation or tampering as follows:
stand-by connected to COM via a 1 k resistor (terminating resistor)
activation connected to COM via a 2k to 6k resistor
tampering connected to COM via a less than 700 resistor (short-
circuit) or connected to COM via a more than 6k resistor
(loop termination)
12 34
ON
OFF
1k
1k
+U
GND
01
02
COM
03
04
fig. 2 SA-200 magnetic detector connection
1k
1k
12 34
ON
OFF
+U
GND
01
02
COM
03
04
fig. 3 JS-20 Largo detector connection
1k
1k
12 34
ON
OFF
+U
GND
01
02
COM
03
04
fig. 4 One-loop connection of JS-25 Combo
1k
1k
1k
1k
12 34
ON
OFF
+U
GND
01
02
COM
03
04
fig. 5 Two-loop connection of JS-25 Combo (01 GBS, 02 PIR)
12 34
ON
OFF
+U
GND
01
02
COM
03
04
fig. 6 Connection of multiple detectors to the inputs – schematically
The used input zone must be terminated by a 1k resistor in stand-by
state.
When connecting a trigger contact to the zone, always use a parallel
1k resistor. Thus it is possible to connect up to 5 trigger contacts in
series.
Tamper contacts should be connected in series (without resistors).
They therefore interrupt the whole loop. You can use an unlimited
amount of tamper contacts which can be combined with trigger
contacts (with parallel resistors).
The loop (input) reaction can be set. The NATURAL = delayed loop
reaction is set in the factory.
If you enrol a wireless device to the hard-wired input address, the
corresponding terminal will be disabled (it will not affect the system).
If you do not intend to use the hard-wire input or enrol a wireless
device to its address, switch the corresponding switch to the OFF
position (switch off the input).
3.3 Installation of additional hard-wire input
modules
By adding the JA-82C module it is possible to extend the amount of
inputs to twenty (addresses 01-20). When only one JA-82C module is
installed (extension to twenty inputs) module position 4 must be used -
see fig. 1.
When two JA-82C modules are installed, the maximum amount of thirty
hard-wire inputs (addresses 01-30) is reached. All hard-wire inputs behave
identically: they are double balanced inputs which are able to sense stand-by,
activation and tampering and for which examples of connection and
conditions stated in Chapter 3.2 apply in full scope.
When you install the module, relabel the terminal description with a
sticker from the module package pursuant to the current position for which
the module is intended (inputs 11-20 or 21-30). Insert plastic spacing posts
on the openings in the module on the connector side and insert the prepared
module to the selected position in the main board.
3.4 Radio module installation
The JA-82R radio module is installed in position 13 (see fig. 1). The
module antenna is included in the package and it should be inserted in the
groves on the side of the side of the box (see fig. 17). The antenna
connectors are thus connected to the pins on the JA-82R module. The
module installation enables the system to enrol wireless devices.
3.5 Y,X,V communicator module installation
Screw the selected communicator onto the holder bolted in the bottom
right corner of the control panel box.
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Jablotron JA-83K wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info