494327
7
Zoom out
Zoom in
Vorherige Seite
1/8
Nächste Seite
37
By means of the next setup commands it is possible to program
the toggle mode when you are in the programming mode.
CHOOSE ACTION RESULT RESULT
Setting Setup Command Blink code LED flashes
including Address
1
)
No IR-toggle 2 x Bright 12 14 x
IR-toggle mode 2 x Dim 5 7 x
Bold is default setting. All settings can be programmed separately.
1
) The sum of the blinks of the letter code and the setup command.
3. If you wish to program the IR-toggle mode please send a
"DIM" command to the IRIX35, through the power line by an
X-10 compatible transmitter to the IRIX35. (E.g. Marmitek
Home Control Box or Programming Unit (
PRU256
)).
4. Shortly press the programming switch or wait 60 seconds to
leave the programming mode and return to the normal
operation mode.
Note: The IRIX35 will only transmit the
programmed letter code of the IRIX35.
Independently of the letter code setting of the
remote control.
!
38
Programming the IRIX35 (cont'd.)
Auto detect the state of the two-way Marmitek X-10
modules
In the IR-toggle mode the IRIX35 operates with two-way
communication. This means that, when you activate the IRIX35
for the first time, the IRIX35 needs to detect the actual status
(ON or OFF) of all 16 installed modules in the same letter code.
The IRIX35 also needs to detect if the module reacts to group
commands. This scan can automatically be processed when you
activate the learn mode.
Address Learn Mode
The learn mode can be enabled by pressing the program button
between 6…9 seconds (LED blinks slowly, flash 5 x every
2 seconds).
Note: This mode must be entered only, if the IRIX35
is programmed in "IR-toggle mode"!
In learn mode the IRIX35 will transmit several commands to see
which external addresses (within the programmed letter code)
will respond to group commands. This is an automated process,
2
!
39
which must be carried out one time after installation of all
programmed modules. Only two-way modules can be detected
(responding to status request). In this mode the IRIX35 detects
which actuators are present in the programmed letter code. This
is necessary to enable the IRIX35 to follow the status of each
module when responding to group commands All Units Off, All
Lights On and All Lights Off. If the status of one ore more
modules has changed by means of a group command the next
transmitted code will be automatically reversed.
This process in which the lights will be switched ON and OFF
automatically will last for approximately 3 minutes. During this
process the LED will continuously show short blinks. Do not
switch or transmit any code over the power line during this
process. After the LED stops blinking the process is completed.
After this procedure the IRIX35 will revert to the operation
mode.
Note: All transmitters which can disturb this
automated process like Computer Interfaces,
Movement sensors etc. must be switched off from
the mains before starting the learn mode!
Do not operate any switches during this process.
!
40
Installation methods
The IRIX35 is designed to be:
- installed on a standard 50 mm junction box or
- installed below a (ceiling) distribution box or
- mounted on a wall (using supplied power cable).
The infrared "eye" must be in the line of sight of the remote
control as much as possible.
Note: Automatic switching does not just increase
the level of comfort, a number of hazards are also
involved. People may be surprised, or clothing
placed over an electrical heat source may ignite.
Always be aware of these hazards and take the
necessary precautions.
The product must only be opened for installation purposes.
We advise you to have the product installed by a trained and
certified Marmitek X-10 dealer.
If the mains lead supplied is used, the wire ends must be
installed up to the insulation in the connector. There must not
be any bare copper visible.
Never expose the IRIX35 to direct sunlight. Infrared light
components from the sun could seriously affect the operation
of your system.
!
41
Install the IRIX35 at a sufficient distance from high frequency
lighting such as energy-efficient lamps and fluorescent and
compact fluorescent lighting.
To prevent short circuits, this product should only be used
inside and only in dry spaces. Do not expose the components
to rain or moisture. Do not use the product close to a bath,
swimming pool etc.
Do not expose the components of your systems to extremely
high temperatures or bright light sources.
Only connect the product to the mains after checking
whether the mains voltage is the same as the values on the
identification tags. Never connect a power cord when it is
damaged. In that case, please contact your supplier.
Do not open the product: the device contains live parts. The
product should only be repaired or serviced by a qualified
repairman
In case of improper usage or if you have opened, altered and
repaired the product yourself, all guarantees expire. Marmitek
X-10 does not accept responsibility in the case of improper
usage of the product or when the product is used for
purposes other than specified. Marmitek X-10 does not
accept responsibility for additional damage other than covered
by the legal product responsibility.
42
Technical data
Product characteristics
Mains voltage 230 Vac, 50 Hz
Max. power consumption < 2 W
Ambient temperature 0 to 40 °C
Infrared frequency 38 kHz (NEC compatible protocol)
Protection class Class II, Double insulated
Type of protection IP 40 with installation on the wall or
ceiling
IP 20 with installation on the wall.
Standards: IEC 60950
Housing
Dimension (H x W x D) 120 x 80 x 30 mm
Color RAL9001
Power cable
Dimension Length 1.5 m
Color White
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Marmitek IRIX35 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info