Air and other foreign matter in the refrigerant circuit causes abnormal pressure rise, which
may result in equipment damage and even injury. Therefore, the indoor unit and tubing
between the indoor and outdoor unit must be leak tested and evacuated to remove any
noncondensables and moisture from the system.
1.Air purging with vacuum pump
Preparation
Check that each tube(both liquid and gas side tubes) between the indoor and outdoor units
have been properly connected and all wiring for the test run has been completed. Remove
the service valve caps from both the gas and the liquid side on the outdoor unit. Note that
both the liquid and the gas side service valves on the outdoor unit are kept closed at this stage.
Pipe length and refrigerant amount:
Air purging
Connective
pipe length
Less than 5m
More than 5m
Air purging
method
Use vacuum
pump.
Use vacuum
pump.
Additional amount of refrigerant to be charged
R22: (Pipe length-5)x30g/m
R410A: (Pipe length-5)x15g/m
Liquid side: 6.35
R22: (Pipe length-5)x60g/m
R410A: (Pipe length-5)x30g/m
Liquid side: 9.52
Bar
Copper pipe
Clamp handle
Red arrow mark
Cone
Yoke
Handle
Bar
"A"
C: Putting nut on
Remove flare nuts attached to indoor and
outdoor unit, then put them on pipe/tube
having completed burr removal.(not possible
to put them on after flaring work)
Flare nut
Copper tube
Fig.14
Fig.15
D: Flaring work
Firmly hold copper pipe in a die in the
dimension shown in the table below.
Caution
Align the center of the pipes.
Sufficiently tighten the flare nut with fingers,
and then tighten it with a spanner and torque
wrench as shown in Fig.16 & 17.
2. Tightening Connection
Excessive torque can break nut
depending on installation conditions.
Indoor unit tubing Flare nut Pipings
Fig.16
Outer diam.
(mm)
A(mm)
Max.
Min.
6.35 1.3
0.7
9.52
1.6 1.0
12.7
1.8
1.0
12.7
16
1.8
2.2
1.0
2.0
Outer
diam.
Tightening
torque(N.cm)
Additional tightening
torque(N.cm)
6.35
12.7
16
9.52
1500
(153kgf.cm)
1600
(163kgf.cm)
3500
(357kgf.cm)
3600
(367kgf.cm)
2500
(255kgf.cm)
2600
(265kgf.cm)
4500
(459kgf.cm)
4700
(479kgf.cm)
B: Burr removal
1. Completely remove all burrs from the cut
cross section of pipe/tube.
2. Put the end of the copper tube/pipe in a
downward direction as you remove burrs in
order to avoid dropping burrs into the tubing.
Pipe
Reamer
Point down
Fig.13
1. Remove the electrical wiring cover from the outdoor unit by loosening the screws.
2. Connect the connective cables to the terminals as identified with their respective matched
numbers on the terminal block of indoor and outdoor units.
3. Secure the cable onto the control board with the cable clamp.
4. To prevent the ingress of water, form a loop of the connective cable as illustrated in the
installation drawings of indoor and outdoor units.
5. Insulate unused cords (conductors) with PVC-tape. Process them so they do not touch any
electrical or metal parts.
Cover
Terminal block
Screw(1~2,model
dependent)
Cable clamp
OUTDOOR UNIT INSTALLATION
OUTDOOR UNIT INSTALLATION
Connect the cable to the outdoor unit
Fig.17
Fig.18
E: Pipe length
Model
R410A
inverter
split air
condtioner
Max. Length
of refrigerant
pipe(m)
Max. drop
height
(m)
Capacity
(Btu/h)
25
10
30
20
50
65
25
30
<15000
>15000~<24000
>24000~<36000
>36000~<60000
Indoor unit
Power
supply
W 1(L) 2(N) S
W 1(L) 2(N) S L N
Outdoor unit
L N S
L N S
(1)
(2)
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Midea Mission - 27 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Midea Mission - 27

Midea Mission - 27 Zusatzinformation - Englisch - 8 seiten

Midea Mission - 27 Bedienungsanleitung - Englisch - 8 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info