Insert heater with cowl body (1) through the wall cut-out (2),
allow approx. 5 mm to project out of the wall. Mount sealing
frame (3) (the anti-twisting device ensures correct fitting!).
Pre-drill holes for the 6 fastening bolts (4).
4
1
3
2
Remove sealing frame (3) and coat with non hardening mastic
on the side facing the vehicle – do not use silicone!
The sealing frame must be well sealed with respect to
the front sides and the cross bars of the cowl body (1)
as well as towards the outside wall!
Fasten sealing frame (3) to the cowl body using 4 self-cutting
screws (4).
4
3
Screw the sealing frame (3) in contact together
with the cowl body (1) so the anti-twist device
projects out!
9
7
4
6
1
3
5
8
Seal the gap between the hole (6) and the condensation
tube (7) with non hardening mastic – do not use silicone!
Mount the grille (8). Press the entire cowl assembly onto the
vehicle wall and fasten with 6 screws (5).
Screw the water heater securely to the floor of the vehicle
with at least two shackle plates (9) with the screws provided,
B 5.5 x 25, on suitable base (plywood panel, laminated wood
strips or metal base).
Water connection
All pressure and submergible waterpumps up to 2.8 bar
and all mixed combination sets with or without an electrical
switch, can be used for operating the water heater.
If connecting to a central water supply (rural or city con-
nection) or when using more powerful pumps, a pressure
reducer must be used which prevents pressures of greater
than 2.8 bar occurring in the system.
When using submergible pumps, a non-return valve (10 – not in-
cluded in the scope of supply) must be fitted between the pump
and the first branch point (arrow points in direction of flow).
10
13
12
14
When using pressure pumps with high switching hysteresis,
hot water may flow back through the cold water tap. To pre-
vent the backflow, we recommend that a non-return valve
(11 – not included in the scope of supply) be fitted between
the outlet to the cold water tap and the drain valve.
14
11
13
12
When using the Truma Ultrastore together witch the
Truma Ultraflow pressure switch, the use of a non-re-
turnvalve is essential (please refer to the pressure switch
instruction).
In order to guarantee complete emptying of the water
content and ongoing sealing tightness of the water
connections, the enclosed water connectors (12 + 13) and
the safety (pressure relief) drain valve (14) must be used!
John Guest System rigid pipe routing
The water connectors (12 + 13) and safety/drain valve (14)
supplied with the Truma Ultrastore have a 12 mm diameter
fitting and are only approved to use with Original John Guest
piping.
For connecting to rigid pipes with other diameters appropiate
adapters (not included in scope of delivery) must be used.
10
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Truma Ultrastore Rapid GE wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info