539098
75
Zoom out
Zoom in
Vorherige Seite
1/78
Nächste Seite
79
481-017_v01
3
Turn the control clamp to the limit in such a way that the
hand is positioned vertically.
4
Press the fastener button and simultaneously deect the
stand head with the motor part back.
5
Before putting the ingredients into the steel bowl (type
481.64MM only), attach the toothed wheel plastic rim to the
bowl until it sits in the recess.
6
Then twist it in the direction marked on the rim until it stops.
7
Place the bowl on the 3 lips of the stand and put it on the
stand base.
8
Attach the bowl scraper attachment and put ingredients
into the bowl.
9
Place the stand head with the motor part in horizontal
position (you will hear the clicking sound of fastener blocking
clamps).
10
Start-up the mixer with the switch lever and it will make
the bowl turn and the head with drive move pendulum-like.
Never block or stop the oscillatory movement
during operation. It may cause damage to the
housing.
Before emptying the metal bowl, take away
toothed wheel. Removing toothed wheel
facilitates emptying and cleaning of the product.
Working with a stand with scales
Food mixer type 481.67 has the base, which is equipped with
rotating bowl and inbuilt electronic scales, which is an
innovative solution. The base with installed motor makes
the work with whiskers or stirrers easier, so that the user
has „free” hands, whereas the assembled scales enable for
weighting of processed products directly in the base bowl.
The base with the scales is equipped with the scraper blade
and the blade.
Equipment of the blender type 481.67 is
identical to type 481.7 see table (B); the
additional equipment is a stand with scales,
which should be operated according to this
instruction manual.
The base with scales is equipped with safety blocking,
which prevents the damages of the scales sensor, it is
started by blocking knob.
The positions of blocking knob:
OFF – the scales sensor blocked and the scales switched
off – it is possible to start the motor on the base.
ON – the scales sensor unblocked and the scales
switched on it is possible to weight but it is not
allowed to start the motor on the base.
Operating the stand with scales in terms of
cooperation with the drive, mixers, beaters,
rotating bowl and self-gathering spatula is
identical to these actions concerning a stand
without scales, as described in the above
subsections.
Installing the motor on the base with scales,
exchange of accessories and starting te driver
is allowed only when the blocking knob is set
in OFF.
Scales operation
Specication of the scales:
The scope of weighting 3 kg
The measurement accuracy
of the scales +/- 1 g
Power 3V – two batteries 1,5 V,
alkaline, type AA (LR6)
Inserting (replacing) of batteries (Fig. I)
To provide the power supply of the scales it is necessary
to use alkaline batteries 1,5 V, type AA (LR6).
To insert or replace the batteries:
1
Turn the blocking knob to OFF position.
2
Remove the motor from the base.
3
Turn the base with scales upside down and remove the
cover of the batteries bending its fastening with screwdriver
or a coin (according to the arrow on the cover),
4
Insert new batteries paying attention to the polarity (+/-).
5
Replace the cover of the batteries.
The display and the scales keypad
The symbols show on the scales display and the functions of
the buttons are presented in the gure
27
.
Display
28
:
- – negative value
g – grams
kg – kilograms
lb – pounds
TARE – tare
ON/OFF – the button to switch the scales off and on
29
Tarring knob TARE
30
Unit change button UNIT
31
Weighting (Fig. L)
1
Place the base with the scales and rotating bowl on rm
and at surface.
2
Switch off the motor. Place the supplying cord of the
motor so, that it does not inuence the result of weighting.
The head of the base with the motor should be put into lower
position during weighting (in order to limit the inuence of
vibrations on the result of weighting).
3
Turn the blocking knob to ON position, to unblock the
scales and switch it on. In case the blocking knob is in ON
position and the scales is off, it is enough to press the ON/
OFF button (next to the display).
4
Wait until symbol „ ” appears on the display.
5
Select a desired weighting unit with UNIT knob, when
pressing consequently the units „g”, „kg”, „lb” are displayed.
The button of unit change UNIT makes possible to weight
in metric system (g, kg) and in English system (lb) and it
75

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Zelmer 481 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info