12.10 Display messages
NOTE - Here follows a list of alarm messages (in addition to
those explained before) that can be displayed and the
relative machine conditions.
STANDBY: the machine is switched off (the main switch is on I)
and the automatic switching-on/off functions enabled (Pr. 12.7.1).
ANTI-FREEZING: the machine is switched off (the main switch
is on I) and the function protecting boilers from icing-up is enabled
(Pr.12.7.1).
PROGRAMMED CLEANING: it is displayed when the machine is
performing the automatic cleaning of the brew group (Pr. 12.7.1).
ADD COFFEE: the machine, during the grinding, detects the lack
of coffee beans in the relative container (6).
FILL CIRCUIT: this message is displayed if the machine detects
the lack of water in the boilers during a beverage brewing.
After checking if there is actually water in the supply network,
press the button ( ^ in the COFFEE version), until water comes
out properly from the spout (11) and from the brew group (27). In
the COFFEE version the water comes out only from the brew
group
PROGRAMMING: it is displayed during the machine programming
(Pr. 12.6).
REMOVE GROUNDS: it is displayed if the dump box (16) is almost
full (the machine performed the programmed number of brewings).
More brewings can anyway be performed.
OUT OF SERVICE REMOVE GROUNDS: the dump box (16)
is completely full (the machine performed the programmed number
of brewings).
The machine is blocked and no more brewings can be performed
until the dump box is emptied.
CLOSE DOOR: the door (14) is not properly closed.
INSERT BOX: the dump box (16) is not properly inserted.
INSERT DRIP TRAY: the drip tray (12) is not properly inserted.
INSERT GROUP: the brew group (28) is not properly inserted.
GROUP ERROR: the brew group (28) is not properly performing
his working cycle; switch the machine off and call the AUTHORIZED
CUSTOMER SERVICE CENTER.
PUMP ERROR: one of the pumps is damaged. Switch the machine
off and call the AUTHORIZED CUSTOMER SERVICE CENTER.
SENSOR ERROR 01: is displayed when a temperature sensor
fails. Switch the machine off and call the AUTHORIZED CUSTOMER
SERVICE CENTER.
TEMPER. ERROR 01: is displayed when one of the boilers
resistance is damaged. Switch the machine off and call the
AUTHORIZED CUSTOMER SERVICE CENTER.
DESCALING: it is displayed when the machine needs a descaling
intervention, and after performing the programmed number of
brewings. Switch the machine off and call the AUTHORIZED
CUSTOMER SERVICE CENTER.
The descaling interventions are set on working cycles of the
machine, and can be programmed by the maintenance
technician.
MAINTENANCE: it is displayed when the machine needs
maintenance and after performing the programmed number of
brewings. Switch the machine off and refer to the AUTHORIZED
CUSTOMER SERVICE CENTER.
The maintenance interventions are set on working cycles of the
machine, and can be programmed by the maintenance
technician.
12.11 Machine switching-off
Programmed automatic switching-off
This is possible when the function AUTOM.SWITCHING-ON
(Pr. 12.7.1) is enabled and the function TIMES ON/OFF
(Pr. 12.7.1) has been programmed .
At the programmed time the machine goes on STANDBY.
Manual switching-off
This switching-off is necessary if the function AUTOM.
SWITCHING-ON (Pr. 12.7.1) is not enabled.
It can be obtained by switching both the main switch (18) and the
all-pole switch on the 0 position or by disconnecting the plug.
Downloaded from www.Manualslib.com manuals search engine
45

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gaggia Concetto CAP002 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info