555056
7
Zoom out
Zoom in
Vorherige Seite
1/10
Nächste Seite
The JA-80V LAN/PSTN line communicator - 7 - MKA51202
5.10. Initialization of GSMLink communication
After successfully connecting the communicator to the LAN network
913 should be entered to initialise communication to the
www.GSMLink.cz
server (the server will register the IP address of the
communicator).
To access the system remotely via the Internet it is necessary to
register it on www.GSMLink.cz
(after communication has been
initialised). To register the system (see 7.5) you will need the
communicator registration code, which is printed on the label which
you will find on the communicator board.
Note:
the communicator reports regularly to the GSMLink server to update
the communicator’s IP address in the server database (the period of
the regular reports is more frequent the more frequently GSMLink
access is used). If you try to access the alarm system via GSMLink
after the communicator’s dynamic IP address has changed, you can
be notified by GSMLink that it is necessary to wait for the next
regular communication from the system. To shorten this waiting time
you can enter the above sequence (913) on the system keypad
while in service mode or you can do it remotely by calling the
communicator from a phone, whose number was programmed for
this purpose (see the following text).
5.10.1. Tel. number to initialise GSMLink communication
GSMLink communication can be initialised remotely by calling (ringing)
from a phone number which can be programmed by:
914 xx...x 0 where xx...x = phone number (max. 20 digits)
Notes:
After the first ring from the above programmed number the
communicator will report to GSMLink to update its IP address,
this remote way of initialisation is only possible if the phone line
used by the communicator supports CLIP caller ID recognition).
Factory default setting: erased
5.11. Tx SMS center telephone number
To send SMS by CLIP protocol via the telephone line it is necessary to
program the Tx SMS center telephone number by:
942 xx...x 0 where xx...x = Tx SMS center tel. number
Note:
Contact your telephone line provider to learn the Tx SMS center tel.
number.
Factory default setting: erased
5.12. Rx SMS center telephone number
To receive SMS by CLIP protocol via the telephone line it is necessary
to program the Rx SMS center telephone number by:
942 xx...x 0 where xx...x = Rx SMS center tel. number
Note:
Contact your telephone line provider to learn the Rx SMS center tel.
number,
check also how to activate delivery of the SMSes in text form (some
providers convert SMS text into voice messages).
Factory default setting: erased
5.13. Testing reporting to an ARC
To test reporting to an ARC enter:
961a where a = ARC number (1 or 2)
Note:
The event code “Communication test” (ec=31) will be sent to the ARC.
The green LED flashes while the report is being sent, if the red LED
goes off it indicates that the report to the ARC was unsuccessful.
5.14. Testing calls to a phone number
To test that the communicator is capable of calling the phone numbers
programmed into its memories enter:
962M where M is the phone number memory 1 to 8
If memory M contains a phone number, this number will be called and
if the phone call is answered, there will be an acoustic signal.
5.15. Remote programming by the SMS instruction
Instruction PRG can be used to send programming and operating
sequences to the alarm system:
code_PRG_seq,seq,seq...
where:
code is valid access or service code (e.g. 8080 or 1234)
_ space
seq programming sequence usually set via the keypad
Note:
In the sequence can be used characters 0 to 9, and #)
When the valid instruction is received, communicator simulates
entering the keys on the keypad, comma in the SMS is taken as a
pause in the sequence entering
System must be unset and switched to the service mode
The number of sequences in one SMS is limited by the maximum size of
the SMS in the GSM network.
Example: by sending SMS 8080 PRG
08080,201,# the exit delay will
be set to 10s
5.16. Triggering LAN re-login
After entering
935 the communicator will log out of the LAN network and
then re-log in (DHCP updates).
5.17. Communicator reset
Entering 98080 returns the communicator to its factory default settings and
texts, erases all telephone numbers and disables reporting.
5.18. Automatic DHCP
The factory default settings in the communicator expect automatic
DHCP in the LAN network. If you need to enter the network
parameters manually, the automatic DHCP should be disabled with
this sequence and network parameters should be entered manually by
the following sequences before the communicator is connected to the
LAN network.
9300 DHCP disabled
9301 DHCP enabled
Factory default setting: enabled
5.19. Communicator IP address
If DHCP is disabled (see 5.18) program the communicator IP address
by:
931 xxx xxx xxx xxx
where:
xxx…x is IP address
Example: if the IP address is 192.168.1.23 enter:
931 192 168 001 023
Factory default setting: 192.168.001.211
5.20. Network mask
If DHCP is disabled (see 5.18) program the network mask by:
932 xxx xxx xxx xxx
where:
xxx…x is the network mask
Example: if the network mask is 255.255.255.0 enter:
932 255 255 255 000
Factory default setting: 255.255.255.000
5.21. Network gateway address
If DHCP is disabled (see 5.18) program the network gateway by:
933 xxx xxx xxx xxx
where:
xxx…x is the gateway address
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Jablotron JA-80V wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Jablotron JA-80V

Jablotron JA-80V Bedienungsanleitung - Holländisch - 11 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info